background image

-  10  - 

Install onto a wall mount holder 

Note

Wall mount holder is optional. 

1. There are two outlet holes on the wall mount holder. You may remove the

piece of plastic (A) to open the hole accordingly.

2. The wall mount can be fixed to the wall. You may use attached screws to fix it.
3. Connect USB cable and Air Monitor Pro
4. Place Air Monitor Pro into the holder and secure it by Screw (B)
5. Plug to the USB power adapter

Содержание Air Monitor Pro

Страница 1: ... 1 Air Monitor Pro AMP220 User Guide 2018 10 v 1 0 ...

Страница 2: ...Google Play store 11 Using Air Monitor Pro APP 12 Scan Bluetooth air quality broadcast 12 Setup Wi Fi connection 13 Device List 15 Individual Air Monitor Pro Page 16 Using Map 18 Understanding the breathing LED light 19 General safety information 20 Taking care of your device 21 Frequently Asked Questions FAQs 21 Specifications 22 Power 22 Connectivity 22 Sensors Note according to configuration of...

Страница 3: ... 400 PPM Parts Per Million depending on the location People in a high CO2 environment will feel drowsy dizzy have headaches and experience hearing and visual dysfunction It may also cause unresponsiveness and decision delay Formaldehyde One of volatile organic matter indoor From the toxicology research it has been confirmed as carcinogenic substances Formaldehyde can stimulate human skin respirato...

Страница 4: ...sual indicators on the device as well as more detailed information on the app the Acer Air Monitor helps track and gives advice on how to improve the air quality your health and the health of the ones you care about ...

Страница 5: ...llowing items are in your package If anything is missing contact your authorized dealer or distributor Air Monitor Pro USB Cable USB Power Adapter Desktop Holder Quick Guide Warranty Card Note Actual items might differ from illustrations ...

Страница 6: ... different colors to show the current air quality 2 Display Show the air quality index and individual concentrations 3 Light Sensor Measure the ambient illumination 4 Function button Tune On Off the Breathing LED light When the LED light is off the display will display indoor air quality index only ...

Страница 7: ...d to cloud Off On Resetting Flash Flash 6 Wi Fi Red LED 7 Wi Fi Reset Button To reset Wi Fi configuration please use an unfolded paperclip to press and hold this button until the Wi Fi Red LED lights up 8 Communication Ports Communication and I O Ports 1 NO2 Dry contact 2 2 NO1 Dry contact 2 3 A RS485 A 4 B RS485 B 5 GND Ground 6 VCC 5V 5V output 9 Micro USB Connect to power adapter ...

Страница 8: ...Q Indoor Air Quality Temp Celsius Humi Relative Humidity PM2 5 Particular Matter size 2 5 µm PM10 Particular Matter size 10 µm TVOC Volatile Organic Compound CO2 Carbon Dioxide CO Carbon Monoxide HCHO Formaldehyde Ozone O3 Illum Environment illumination 2 Real time Measurement The latest measurement of sensor 3 Version Air Quality and sensor version 4 Wireless Status Show the exists of Wi Fi and B...

Страница 9: ... Getting started Install on a desktop holder 1 Attach the appropriate power adapter plug to the USB power adapter 2 Gently insert and secure Air Monitor Pro along the two inner grain of the desktop holder ...

Страница 10: ...the wall mount holder You may remove the piece of plastic A to open the hole accordingly 2 The wall mount can be fixed to the wall You may use attached screws to fix it 3 Connect USB cable and Air Monitor Pro 4 Place Air Monitor Pro into the holder and secure it by Screw B 5 Plug to the USB power adapter ...

Страница 11: ...ways place the Air Monitor such as the function key is facing upwards Do not cover the light sensor or place the device in the shade in order to ensure the best experience Download the Air Monitor Pro app from either the iOS App Store or the Google Play store Note Mobile system requirements Android Android 5 0 and above iOS iOS 10 0 and above ...

Страница 12: ...g Air Monitor Pro APP Scan Bluetooth air quality broadcast You can directly scan and read the immediate value without logging in to the account If you have logged in to your account you can go through the menu ...

Страница 13: ... setup Air Monitor Pro for remote monitoring 1 Please use an unfolded paperclip to press and hold the Wi Fi Reset button until the Wi Fi Red LED lights up Your Air Monitor Pro will show an temporary Wi Fi access point named AcerAMP XXXX where XXXX are 4 English alphabet or number 2 Go to your phone s Wi Fi Settings and connect it to AcerAMP XXXX signal ...

Страница 14: ...ck to Air Monitor Pro setting page Select an SSID of Wi Fi access point that allows your Air Monitor Pro to connect to the Internet 4 After completing the Wi Fi setup process you can update the name of Air Monitor Pro ...

Страница 15: ...d from PM2 5 PM10 TVOC and CO2 values 2 Device Name The Name of Air Monitor Pro that user can define it 3 Air Quality Description The description is generated according to the IAQ 4 Update Time Show the latest update time of sensor measurements 5 Connection Status Green Connected Grey Disconnected 6 Menu List all functions supported by this APP 7 Add Device Add device with current account ...

Страница 16: ...ted from PM2 5 PM10 TVOC and CO2 values 4 IAQ description Description of current indoor air quality 5 Sensor Note 1 Air Monitor Pro has different sensor configurations Note 2 Grey color means the sensor is warming up Illumination Ambient environmental brightness Temp Temperature HUMI Relative Humidity TVOC Total Volatile Organic Compounds PM2 5 Particulate Matter with size less than 2 5 µm PM10 Pa...

Страница 17: ...ollutants 8 Sensor Value User select a sensor item and show the current value here and chart below 9 Sensor History Chart The history data of individual sensor selected by user 10 Return Back to the device list page 11 Device Settings Press this icon can switch to the setting page of this Air Monitor Pro ...

Страница 18: ... MAP page can show the location of your Air Monitor Pro The location of Air Monitor Pro is set by user Please switch to the device settings page to set up the location Press the Menu and select Map View to show the map ...

Страница 19: ...olors for each air quality level Refer to the table below for a quick description of these lights Color IAQ Readings Description Green 0 50 Good Yellow 51 100 Moderate Orange 101 150 Unhealthy for sensitive group Red 151 200 Unhealthy Purple 200 Very Unhealthy Note You can press function button to turn on off the breathing LED light ...

Страница 20: ...mes Never place the Air Monitor Pro Near heat or flames In under next to liquids With anything on top of it or covering it Inside a closet or drawer Misuse can cause burns fire electrocution and other hazards Never clean the Air Monitor Pro with the following Water or spray A feather duster A vacuum cleaner Do not open the device or make modifications to it as it will void the warranty Do not use ...

Страница 21: ...holes of the device every six months If there is any dirt please use a brush to gently remove the dust and keep the vents clear Frequently Asked Questions FAQs For frequently asked questions please refer to our website http home cloud acer com tw airmonitor qaa ...

Страница 22: ...tion Detection Method Temperature Unit O C Range 0 80 Resolution 0 1 Accuracy 1 0 Semiconductor Relative Humidity Unit Range 0 100 Resolution 0 1 Accuracy 5 0 Semiconductor TVOC Unit PPM Range 0 02 10 00 Resolution 0 001 Accuracy Relative Accurate Semiconductor CO2 Unit PPM Range 0 10 000 Resolution 1 Accuracy 70 NDIR Nondispersive infrared sensor CO Unit PPM Range 0 500 Resolution 1 Accuracy 20 o...

Страница 23: ...cy Relative Accurate Laser light scattering Ozone Unit PPM Range 0 2 10 00 Resolution 0 01 Accuracy Relative Accurate Electrochemical Illumination Unit Lux Range 0 10 000 Resolution 1 Accuracy Relative Accurate Semiconductor Operating Temperature 0 C 45 C ...

Страница 24: ...interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver...

Отзывы: