Introduction to Refrigerants R32
Site Safety
Installation Safety
Please note that:
Open Flames
Prohibited
Ventilation
Necessary
Operation Safety
Mind Static
Electricity
Must Wear
Protective Clothing
and Anti-Static
Gloves
Don't Use
Mobile Phone
1) Refrigerant Leak Detector
2) Appropriate Installation Location
3) The left picture is the schematic diagram of arefrigerant leak detector
The installation site should be in a well-ventilated condition.
The sites for installing and maintaining an air conditioner using Refrigerant R32 should
be free from open fire or welding, smoking, drying oven or any other heat source
higher than 548 which easily produces open fire.
When installing an air conditioner, it is necessary to take appropriate anti-static meas-
ures such as wear anti-static clothing and/or gloves.
It is necessary to choose the site convenient for installation or maintenance wherein
the air inlets and outlets of the indoor and outdoor units should be not surrounded
by obstacles or close to any heat source or combustible and/or explosive environment.
If the indoor unit suffers refrigerant leak during the installation, all the personnel
should go out till the refrigerant leaks completely for 15 minutes. If the product is
damaged, it is a must to carry such damaged product back to the maintenance station
and it is prohibited to weld the refrigerant pipe or conduct other operations on the
user's site.
It is necessary to choose the place where the inlet and outlet air of the indoor unit is
even.
It is necessary to avoid the places where there are other electrical products, power
switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under
the lines on two sides of the indoor unit, and also prevent mechanical damage from
occurring.