Page | 15
Troubleshooting
Symptoms
Corrective Action
Turntable fails to Rotate
Plug power cord into an available 120VAC
outlet.
Turn power switch to ON position.
Rotate speed control knob clockwise to
increase speed.
Verify the 120VAC outlet is operating
property.
Check/ replace controller fuse
.
Lift Fails to Raise
Verify height adjustment locks loosened.
Verify lift lowering valve is tight.
Verify lift has oil in it.
Turntable Drive is Turning
but top is Stationary
Verify setscrew in table top hub is tightly
secured.
Verify setscrew has not sheared. Replace
setscrew if required.
Verify setscrew is lined up with shaft keyway.