11
Service should be performed by qualified and authorized personnel only.
Warning:
Disconnect the power supply from the ACE. BOIL water system before carrying out maintenance on it。
•
Keep the ACE.BOIL water system in a dry, clean space. Minimize exposure to dust. Power button or other controls should never be wet.
•
If the unit gets wet, power it off immediately. Wait for the unit to dry completely before powering it on again.
•
Clean exterior surfaces of the unit with a soft, lint-free cloth. Never use alcohol, paint thinner, benzene or other solvents to clean this
unit. Never use an abrasive material such as a brush or scouring pad to clean surfaces.
•
Always test your cleaning solution on an inconspicuous area before applying to the entire surface.
•
Wipe surfaces clean after applying cleaner.
•
Never expose the unit to vibration.
•
Ensure that all cabin ventilation outlets are always free.
•
In the event of mechanical/power failure or damage, do not attempt to repair the system unit or wires. Refer all such problems to an
authorized technician.
•
If the ACE.BOIL water system needs service, please consult the authorized dealer, unauthorized service may void the warranty.
•
Close/open system valve and safety valve every 6 months.
•
Clean aerator once a year.
Regular maintenance of the ACE.BOIL water system can help prevent damage or downtime.
Read and follow assembly instruction. If the ACE.BOIL water system does not functioning properly please check troubleshooting table. If
the water system still not working properly, disconnect it and contact authorised ACE customer service for assistance. When calling for
assistance please provide your product model and serial number.
Care and Maintenance
Troubleshooting
Symptom
Possible Cause
Solution
No water flowing, the water is
flowing too slowly.
- Main water supply valve is turned off.
- Safety valve is turned off.
- Turn on the main water supply valve.
- Turn on the Safety valve.
- No connection between faucet, boiler, filter
and Safety valve.
- Connect all the cable and hose correctly.
- Filter is not installed correctly.
- Tighten filter.
- Hoses are kinked.
- Check whether hoses are kinked.
- There is limescale or dirt in the aerator.
- Clean/replace the aerator.
The water is sputtering or is
irregular.
- There is no or too little water pressure.
- Check the water pressure. It should be above 1.0 bar. Check
a different tap. If the pressure is also low there, check the
mains water tap and contact your water supplier.
No boiling water
- The boiler is powered off or not connected to
power supply wall socket(Red LED light is off.).
- Connect to power supply wall socket and press the Power
button on the boiler to power on it.
- The boiler has not yet reached the correct
temperature.
- Check whether the red light is blinking and wait until the red
light is lit up.
- Current limit fuse is burned out and cut off
electric power due to over current.
- Check the fuse and if found to be burned out , replace fuse
with a new one, see below picture A/B.
- Faulty cables/hoses
- Contact ACE Water Systems service.
- Faulty Safety valve
- Contact ACE Water Systems service.
- Faulty function of boiler.
- Reset the boiler by pressing the Power button to "Off" position
and back to "On" position after 30 sec..
A.
B.
Содержание ACE.BOIL
Страница 1: ...WATER SYSTEM S ACE BOIL Water System 1 1 2 2 3 8 9 9 10 12...
Страница 2: ...1 IN OUT X 1 X 1 X 2 X 1 X 1 A B X 1 X 1 X 1 X 1 X 1 Unit mm...
Страница 3: ...2 IN OUT...
Страница 4: ...3...
Страница 5: ...4 1 2 A A B B C 3 34 35 G 3 8 G 3 8 G 3 8...
Страница 7: ...6 5 6 A B min 10cm G 3 8 G 1 2 G 3 8...
Страница 8: ...7 7 B A C D E F 2 min...
Страница 9: ...8 8 0 1 C D 0 1 A B...
Страница 10: ...9 9 A B 10 A B...