Installation and Operation Manual
Appendix
F Alarm Forwarding
ACE-3105, ACE-3205 Ver. 5.2
3BTDM-to-PSN Alarm Forwarding
F-7
Figure
F-17. TDM Pseudowire Failure in Structure-Agnostic Mode
•
RAI state (see
and
) – In structure-agnostic mode, RAI
signals are sent transparently from end to end.
Forwarding in Structure-Aware Mode
The structure-aware (structured) mode is divided to two subtypes:
trail-terminated and trail-extended.
Trail-Terminated Mode
In structure-aware trail-terminated mode, alarms are forwarded depending on the
TDM failure type:
•
TDM channel error (see
) – causes the TDM PW to enter a
'forward-detect-state' and use the L and M bits (L=1, M=0) of the CESoPSN
control word to propagate the alarm towards the remote ACE unit. Then,
upon receiving the L and M bit values, the remote ACE unit generates Trunk
condition signals towards the remote TDM end.
Figure
F-18. TDM Channel Failure in Structure-Aware Trail-Terminated Mode
•
TDM pseudowire error (see
) – causes the local ACE to send Trunk
condition signals towards the TDM end, and to propagate the alarm in the
upstream direction over the PSN using the R bit (R=1) of the CESoPSN control
word, while denoting PSN RDI.
Содержание ACE-3205
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......