Ace Plus EX-G033B Скачать руководство пользователя страница 8

 

Performance Guide for HDMI over LAN Cable Transmission 

Performance rating 

Type of LAN cable 

Wiring 

Shielding 

CAT5 

CAT5e 

CAT6 

Unshielded 

(UTP) 



 



 



 

Solid 

Shielded (STP) 



 



 



 

Unshielded 

(UTP) 



 



 



 

Stranded 

Shielded (STP) 



 



 



 

Termination

 

Please use 

EIA/TIA-568-B

 termination (

T568B

) at any time 

  

 

Limited Warranty

 

 

 

 

The SELLER warrants the 

EX-G033B/EX-G033A RS-232 over CAT5 Extender

 to be free from 

defects in the material and workmanship for 1 year from the date of purchase from the SELLER or an 

authorized dealer. Should this product fail to be in good working order within 1

 

year warranty period, 

The SELLER, at its option, repair or replace the unit, provided that the unit has not been subjected to 

accident, disaster, abuse or any unauthorized modifications including static discharge and power 

surges. 

Unit that fails under conditions other than those covered will be repaired at the current price of 

parts and labor in effect at the time of repair. Such repairs are warranted for 90 days from the day of 

reshipment to the BUYER. If the unit is delivered by mail, customers agree to insure the unit or 

assume the risk of loss or damage in transit. Under no circumstances will a unit be accepted without a 

return authorization number. 

The warranty is in lieu of all other warranties expressed or implied, including without limitations, 

any other implied warranty or fitness or merchantability for any particular purpose, all of which are 

expressly disclaimed.   

Proof of sale may be required in order to claim warranty. Customers outside Taiwan are 

responsible for shipping charges to and from the SELLER. Cables are limited to a 30 day warranty and 

cable must be free from any markings, scratches, and neatly coiled.   

The content of this manual has been carefully checked and is believed to be accurate. However, 

The SELLER

 

assumes no responsibility for any inaccuracies that may be contained in this manual. 

The SELLER will NOT be liable for direct, indirect, incidental, special, or consequential damages 

resulting from any defect or omission in this manual, even if advised of the possibility of such damages. 

Also, the technical information contained herein regarding the EX-G033B/EX-G033A features and 

specifications is subject to change without further notice. 

 

ACE PLUS CORP.

 

Headquarters : 

9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian, 

Taipei, Taiwan 231

TEL: +886-2-2912-4201

FAX: +886-2-2912-3164

Website: 

www.ace-plus.com

 

Page 

8

 of 

8

Содержание EX-G033B

Страница 1: ...xtender EX G033B for Point to Point EX G033A for Cascadable User Manual ACE PLUS CORP Headquarters 9F 2 No 190 Sec 2 Jung Shing Rd Hsin dian Taipei Taiwan 231 TEL 886 2 2912 4201 FAX 886 2 2912 3164 W...

Страница 2: ...uctions and warnings marked on this unit z Do not attempt to service this unit yourself except where explained in this manual z Provide proper ventilation and air circulation and do not use near water...

Страница 3: ...annel between local and remote sites For EX G033A the same source unit as EX G033B but on the receiving side the receivers can be cascadable up to 32 units This structure allows users to control tens...

Страница 4: ...upon request Power supply 5V 2A DC Power consumption 1 Watt max Operation temperature 0 40 C 32 104 F Storage temperature 20 60 C 4 140 F Relative humidity 20 90 RH no condensation Package Contents 1x...

Страница 5: ...EX G033B RX EX G033A TX 0 ID 6 pin DIP switch setting EX G033A RX 1 31 CAT 5e cable 1 000 meters 1 100 yards ACE PLUS CORP Headquarters 9F 2 No 190 Sec 2 Jung Shing Rd Hsin dian Taipei Taiwan 231 TEL...

Страница 6: ...ter Cascade OFF ID Bits are composed of 5 bits and the left most bit is the highest bit As cascade bit is set to off as shown above the EX G033A acts exactly like EX G033B and all the serial command s...

Страница 7: ...mission length than stranded STP CAT6 cable For long extension users solid cables are your only choice 3 To reduce the interference among the unshielded twisted pairs of wires in CAT 5 5e 6 cable you...

Страница 8: ...oss or damage in transit Under no circumstances will a unit be accepted without a return authorization number The warranty is in lieu of all other warranties expressed or implied including without lim...

Отзывы: