Reinforced Activation Mode   

For  batteries  that  cannot  be  charged  normally,  might  be  in  poor  condition  due  to 

temporarily over draining or sulfation, manually switch on Reinforced Activation Mode. 

The 

Reinforced  Activation  Mode

  removes  sulfate  residues  from  battery  plates  and 

attempts to reactivate battery chargeability by higher voltage pulse charging .  

 

Maximum charging time of 

30 minutes 

is suggested to prevent battery damaging.  

Remarks:  

 

Reinforced activation is limited for those batteries:   

 

       * with physically damaged electrode(s). 

       

       * with exceedingly contaminated electrolyte solution. 

     

       * with insufficient electrolyte solution. 

 

       * over-period  storage.      

            

Do not 

exceed maximum charging time of 

30-minutes

Discontinue charging when battery housing temperature reaches or  

       above 45-50˚ C. 

 

 

 

  

      

 

Содержание AD-2002

Страница 1: ...ger for 12V Lead Batteries Powered by the new INTEC POWER XT3 technology featuring microprocessor controlled 4 stage charging Providing easy operation fast charging instant battery charge monitoring improved battery performance and extended battery lifespan ...

Страница 2: ...Compact Easy To Operate 2 ...

Страница 3: ...e Maintenance free Marine deep cycle AGM Gel cell Cars Trucks Motorcycles vans RVs ATVs and SUVs Boats Trolling motors Personal watercraft Lawn mowers Farm equipment Tractors High performance engine starting Audio Solar Airplanes Power Sport and Stand By Power Snowmobiles Etc ...

Страница 4: ... Portability Built In Battery Tester Error Check Charging Mode State of Charge Voltage Capacity Intec Power XT3 Technology Regulates 4 Stage Charging Maintenance Mode Maintains Peak Battery Performance Reinforced Activation Mode Improves Chargeability of Poor Batteries Safety Features Prevents Accident Damage Occurrence ...

Страница 5: ...eup 5 Intec Power XT3 regulates the whole system under 4 stage charging platform Uniquely formulated 2 step Constant Voltage Charging combined with Constant Current charging which optimizes battery charging performance and Pulse Charging which helps reduce battery plate sulfation Maintenance Charging mode w Auto Wake up function is automatically switched on upon completion of charging maintaining ...

Страница 6: ...SMPS transfers power from a source like mains power to a load such as a personal computer while converting voltage and current characteristics Unlike a linear power supply the pass transistor of a switching mode supply continually switches between low dissipation full on and full off states and spends very little time in the high dissipation transitions which minimizes wasted energy Ideally a swit...

Страница 7: ... lead acid battery during use small sulfate crystals form but these are normal and not harmful During prolonged charge deprivation however the amorphous lead sulfate converts to a stable crystalline that deposits on the negative plates This leads to the development of large crystals which reduces the battery s active material that is responsible for high capacity and low resistance Sulfation also ...

Страница 8: ...to reactivate battery chargeability by higher voltage pulse charging Maximum charging time of 30 minutes is suggested to prevent battery damaging Remarks Reinforced activation is limited for those batteries with physically damaged electrode s with exceedingly contaminated electrolyte solution with insufficient electrolyte solution over period storage Do not exceed maximum charging time of 30 minut...

Страница 9: ...ore current than normal Batteries with lower charge rate tends to ignition failure Maintenance mode helps keep batteries in optimum condition ready for instant engine ignition and use 2 Improves battery chargeability For batteries that remain unchargeable after Reinforced Activation Mode might be in poor condition due to over draining or sulfation lead to charging failure showing Er1 Er2 or Er3 on...

Страница 10: ...us in both voltage holding and charge percentage Battery capacity level in with 10 increment from 10 to 90 and FUL i e 100 Error codes are shown on the indicator when failures occur during charging process Refer to the Error Code chart for further details as in the right table and manual Er0 System Error Contact Technician Er1 Reverse polarity connection Insufficient battery voltage Loose terminal...

Страница 11: ...ircuit Protection Reverse Polarity Protection Battery Tester None Diagnoses Battery Condition Selects Charging Program for Different Types Of Battery Prevents Over Charge Other Features Limited Programmable Functions Includes Auto Charge Reinforce Activation Desulfation Multiple Battery Charge Optimal Charging Application Separate Charge for Different Types of Battery Universal Charger for all 12 ...

Страница 12: ...ged to 10 5V Specific Gravity 1 14 Brand Model Charging Rate Charging Time Hr Specific Gravity aft charge Voltage 20Min after full charge Charging ACDelco I 7016 10A 04 19 1 28 13 3V 110 Schumacher WM 6000A 10A 04 25 1 23 13 1V 100 Black Decker VEC 1087CBD 10A 03 57 1 20 12 7V 80 Data listed above are for reference only ...

Страница 13: ...ion Over Charge Shutoff Shuts off the circuits at full charge Short Circuit Guard Short Circuit protection is programmed Electric Surge Protection Surge protection device is equipped Overheat Suppression Charging shuts off before the unit overheats Spark Free clamps Generates no sparks at contact ...