Fusion Instructions: He44 (0) 845 862 6400.
3
INS309 Rev1
Mains power 230v, 2.5mm
2
gauge
DMX Control
FUSION HUB
FUSION HUB
Small FUSION hub can power 1-2 FUSIONS
Large FUSION hub can power 1-8 FUSIONS
Recommended cable outer diameter = 6-12mm
Recommended cable outer diameter = 4-8mm
24 or 48 LED variants
24V input
DMX input
Cables between FUSION Hubs
not supplied
Max 300M
Max 300M
Maximum 54 fittings due to restrictions on cable size (2.5mm2), before new mains supply required.
Dependent on Cable size and carrying capacity. See table below.
Maximum 512 Channels.
Max 300M. Standard cable
length is 2M. Extension leads
are available.
1mm
2
1.5mm
2
2.5mm
2
Current Carrying capacity
15A
19.5A
27A
O/D H07RNF approx
9.1mm
9.8mm
11.6mm
Fittings which can be run before new power feed required.
30
39
54
79mm
45°
45°
0°
79mm
140mm
Ø
Only to be installed by a qualified electrician.
Installation must be carried out in accordance with local regulations.
Turn off mains power to the driver during installation and any
subsequent dis-connecting or re-connecting at the fitting.
Use correct polarity when wiring. If in any doubt contact the installation
he44 (0) 845 862 6400.
Do not cover the luminaires or drivers with thermal insulation or vapour
barrier (see air space guidance).
acdc luminaires are designed for lighting applications and must not be
used for any other purpose.
FUSION INSTALLATION
FUSION INSTALLATION