FUSION HUB

FUSION HUB

Small FUSION hub can power 1-2 FUSIONS

Large FUSION hub can power 1-8 FUSIONS

Recommended cable outer diameter = 6-12mm

Recommended cable outer diameter = 4-8mm

24 or 48 LED variants

24V input

DMX input

Cables between FUSION Hubs

not supplied

Max 300M

Max 300M

Maximum 54 fittings due to restrictions on cable size (2.5mm2), before new mains supply required.

Dependent on Cable size and carrying capacity. See table below.

Maximum 512 Channels.

Max 300M. Standard cable

length is 2M. Extension leads

are available.

1mm

2

1.5mm

2

2.5mm

2

Current Carrying capacity

15A

19.5A

27A

O/D H07RNF approx

9.1mm

9.8mm

11.6mm

Fittings which can be run before new power feed required.

30

39

54

79mm

45°

45°

79mm

140mm

Ø

Only to be installed by a qualified electrician.

Installation must be carried out in accordance with local regulations.

Turn off mains power to the driver during installation and any 

subsequent dis-connecting or re-connecting at the fitting.

Use correct polarity when wiring. If in any doubt contact the installation 

he44 (0) 845 862 6400.

Do not cover the luminaires or drivers with thermal insulation or vapour 

barrier (see air space guidance).

acdc luminaires are designed for lighting applications and must not be 

used for any other purpose.

FUSION INSTALLATION

FUSION INSTALLATION