![ACDC Motorized Solutions RollerGlide Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/acdc-motorized-solutions/rollerglide/rollerglide_owners-manual_3859042006.webp)
6
FIGURE 3
RollerGlide
Electronic Controller
1.
Motor direction, change plug as needed
A = Right side installation B = Left side installation
2.
Auto-Close, move the link on J1 as needed
ON
Off
1 link
1
2 link
2 link
3
3 link
Auto-Close uses a safety circuit requiring a link to be connected
between CO and IR on the terminal block (X4)
3.
Remote control, add and erase push button
4.
Open and close controls
5.
Obstruction force controls
6. Terminal
Block
(X4)
Tag Function
External
device
+24
24V DC output
*photoelectric detector
0V
24V DC output
photoelectric detector
CO
Ground
*Manual switch, normally open
BT
Input
Manual switch
CO
Ground
photoelectric detector, normally closed
IR
Input
photoelectric detector
*Photoelectric detector
Remove the safety link from CO and IR
Connect to power +24 and 0V, the switch to CO and IR
The detector must provide a closed circuit that opens when beam is broken
*Optional fixed door control switch
Connect to CO and BT, the switch is normally open, closing when pressed