Installation Manual  I  Installation

7

MP4010-1903

3.1 Installation Notice

Only qualified service technicians/electricians should perform 
the installation to ensure that all electrica safety requirements are 
met and that all wiring and plumbing installations are performed 
in accordance with all national, state and local codes.
The installation must conform with local codes.

LOCATION COMBUSTIBLE

NONCOMBUSTIBLE

SIDES

1”

0”

REAR

2”

0”

FIGURE 1: EQUIPMENT CLEARANCE INFORMATION

3.2 Unpacking

This appliance was carefully inspected before shipment from the 
factory. The transportation company assumes full responsibility 
for safe delivery to the customer until customer acceptance 
of the package. Careful inspection of the packaging and the 
appliance should be completed before acceptance from the 
transportation company.

3.3 Steamer Lifting

Steamers are heavy enough to require additional manpower or 
powered assistance when installing or moving the steamer.

When moving the equipment manually make sure there are 

enough people for the task as the equipment is heavy. 

 Make sure the equipment is not dropped during moving. 

People doing the carrying could be seriously injured and/or the 
equipment damaged. The manufacturer does not accept any 
responsibility for damage resulted from such actions. 

3 INSTALLATION

3.4 Location and Placement

The AccuTemp Evolution steamer can be placed on a 
commercial kitchen counter-top, flush mounted or installed 
on a AccuTemp Evolution steamer stand. Provisions should be 
incorporated in the kitchen to ensure an adequate supply of 
fresh air for proper combustion and ventilation (FIGURE 1).

The steamer must be installed in a level condition. An out of 
level condition may cause erratic operation and damage to 
the steamer. Damage of this kind is not covered by the limited 
warranty. Use a spirit level resting on the top surface of the 
steamer to ensure it is level front to back and left to right.

For the correct operation of the steamer it is important that 

it is leveled in a horizontal position.

Placement on an unlevel or uneven surface may result in 

performance faults. Only professional installation of the device 
guarantees it high-quality operation.

Check proper setting of the equipment by placing a hotel 

pan filled with water inside the steamer and observing the water 
level.

 A minimum clearance of 10 inches must be allowed for 

on the left hand side of the unit for maintenance access to the 
unit. Failure to provide this may limit the effectiveness of service 
dispatch and incur additional costs not covered by warranty.

Counter Top Placement

In a counter top installation the steamer can be leveled using 
the adjustable legs. Once this is complete it is required that the 
supplied (4) rubber foot tips be installed to keep the steamer 
from possibly sliding on the counter top under normal use.

3.5 Stand Installation

If an AccuTemp Evolution Steamer Stand is used ensure the floor 
is level and place the two locking casters to the “ON” position.

 

When using a stand that is equipped with casters, the floor 

surface must be level and flat. Failure to do so can result in a 
“tipping” hazard that could result in serious injury.

3.5.1 Single Steamer Stand Installation Instructions

The AccuTemp single stand can be equipped with adjustable 
height feet or non-adjustable casters (FIGURE 3). 
1.  Before mounting a steamer on the stand with casters, 

engage the two front locking casters, pressing on the “ON” 
handle of the brake mechanism. 

2.  To mount the steamer, carefully lift and place it on the 

horizontal mounting brackets ensuring that the (4) mounting 
holes on the underside of the Evolution are lined up with 
mounting holes of the brackets. 

3.  Then, using a 7/16” wrench, fasten one pair of the 1/4” -20 

hex bolt and 1/4” split lock washer through the underside 
of each stand bracket mounting hole into the Evolution and 
tighten securely. 

4.  With the SNH-10 stand, level the steamer by adjusting the 

feet found at the ends of each stand leg, either up or down 
as needed.

 

When installing units on a double stand, always install the 

lower unit first. Installing the upper unit first could cause the 
stand to topple.

FOR COMBUSTIBLE & NONCOMBUSTIBLE BUILDING MATERIALS

LOCATION
LEFT

3”

RIGHT

3”

REAR

3”

FOR OTHER SOURCES OF HEAT: FRYERS, OPEN RANGE, STEAM VENTS.
For open flame, this is the minimum distance from the flames while they 
are in operation.

Содержание EVOLUTION Series

Страница 1: ...installation initial field start up and complete the equipment adjustments described in this manual IMPORTANT WARRANTY INFORMATION WARRANTY REGISTRATION STARTUP FORM INSIDE THIS MANUAL MUST BE REMOVED...

Страница 2: ...GENERAL INFORMATION PAGE 5 INSTALLATION PAGE 7 OPERATION USE PAGE 14 OPERATION CLEANING PAGE 18 TROUBLESHOOTING PAGE 21 SERVICE PAGE 22 PREVENTATIVE MAINTENANCE CHECKLIST PAGE 23 WARRANTY PAGE 24 DOC...

Страница 3: ...e do not attempt to operate this appliance Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance...

Страница 4: ...ns Name Technicians Email Additional Info 1 Is the steamer being installed at an altitude greater than 2 000 feet Tick Box 2 Is the steamer level Tick Box 3 Is the wall receptacle positioned in a low...

Страница 5: ...n less YES NO Type of NEMA Plug Tick One Tick One L6 30P 208 240V 6kW L16 20P 480V 14kW L15 30P 208 240V 10kW IEC 60309 2 230 415V 15 50P 208 240V 15kW 15 Does the Low Water Light and Alarm turn OFF o...

Страница 6: ...used here draw attention to activities that may influence safety health protection and the necessity for servicing They help you to prevent problems and the advice will make your work easier WARNING I...

Страница 7: ...the base model E Electric B is the size of the unit 6 pan CCC is the supply Voltage D is the number of phases 1 or 3 E is the control series D Manual Fill E Autofill F is the energy input G is the ti...

Страница 8: ...ult in performance faults Only professional installation of the device guarantees it high quality operation Check proper setting of the equipment by placing a hotel pan filled with water inside the st...

Страница 9: ...ounting hole into the Evolution and tighten securely 4 Once the bottom steamer has been installed carefully lift and place the top Evolution steamer on the horizontal mounting brackets ensuring that t...

Страница 10: ...d must be filled throughout the cooking process to assure consistent cook times Do not use the Low Water Indicator as your indication that this steamer requires water as this actually turns off the he...

Страница 11: ...pplied with single or 3 phase 3 For use on individual branch circuit only 4 Do not connect to a circuit operating at more than 150V to ground 5 Dimensions outside brackets are inches in brackets are m...

Страница 12: ...e steamer If hot is used temperature must be less than 180 F The hose must not be sharply bent kinked or twisted If the steamer is close to a wall use a right angle fitting to prevent kinking the hose...

Страница 13: ...ng should have no restrictions and no low spots where water can accumulate Ventilation piping can be directed upwards toward hoods or downward towards floor drains Slightly different approaches are re...

Страница 14: ...e steamer vent to a floor drain to allow water condensing in it to run unimpeded into the floor drain 3 For downward sloping extension to a floor drain ONLY ID or larger reinforced silicone hose auto...

Страница 15: ...brushes metal scouring pads to clean the cooking chamber bottom 4 1 Operation Introduction The AccuTemp Evolution steamer uses the time proven method of cooking with steam Once the cooking time expire...

Страница 16: ...lation Manual I Operation 15 MP4010 1903 OPERATOR DISPLAY COOK or HOLD DISPLAY TEMPERATURE OVER TEMPERATURE LAMP HIGH WATER LAMP LOW WATER LAMP SET TIMER INCREASE VARIABLE DECREASE VARIABLE ON OFF FIG...

Страница 17: ...the steamer The display will indicate PrE while in Cook Mode and the temperature while in the Hold Mode 2 Once the steamer is preheated and ready to cook the display will indicate the COO Cook Mode or...

Страница 18: ...food into the cooking chamber Shut the door 3 Food will be held at the preset holding temperature The factory default setting is set at 180 F 4 Depress the DISP TEMP button to display the current cook...

Страница 19: ...condensate tray with a clean cloth FIGURE 19 Clean the door gasket inside of door and front face of the cooking chamber Clean water sensors with a non metallic cleaning pad Wipe down corners of cooki...

Страница 20: ...of the steam collector align the 4 retaining fasteners and hand tighten then install the pan rails and the condensate tray Leave the door open overnight NOTE The steamer will not operate without the...

Страница 21: ...activate the chromium oxide passive layer 8 Always rinse the unit with clean water and dry with the steamer door and drain valve open 4 7 5 How to to Protect Stainless Steel All materials used in manu...

Страница 22: ...cooking cabinet 5 4 Steamer Does Not Heat If the operators display doesn t light up see Section 5 1 Verify the steamer door is closed as the unit will not heat when the door is open 5 5 Steam Comes Ou...

Страница 23: ...ducts Inc Technical Service Department or the service call may not be covered by the limited warranty WARNING Only an AccuTemp Products Inc Authorized Service Personnel or Representative must perform...

Страница 24: ...stand casters Monthly Inspect AC power cord for degradation or bare wires Replace if defective or suspect X Inspect door gasket for cuts and degradation Replace if damaged We suggest replacing once a...

Страница 25: ...s or workmanship provided the service agency has received advance approval from AccuTemp factory service to perform the repair or replacement This warranty includes travel time not to exceed two hours...