MP5017-2002
Accu-Steam Gas Griddle
34
6.6 ERROR CODE DISPLAYED
E001 Displayed
Open Temperature Sensor or defective
temperature input on Temperature Control
Board.
E002
Shorted Temperature Sensor or defective input
on the Temperature Control Board.
6.7 FAULT LIGHT ILLUMINATED
When this error is lit an ignition failure of the
appliance has occurred. Following the following
steps:
1. Turn the appliance off
2. Verify that your flexible quick connect gas
line is fully engaged to the appliance gas
input connection if applicable.
3. Verify your gas shutoff valve is turned on to
supply gas to the appliance.
4. Once these have been verified and 1 minute
has passed since it was turned off turn the
appliance on.
Fig 6.A
Fault Light
6.8 OVER-TEMP LIGHT ILLUMINATED
When this error is lit an over-temp condition
was sensed and will turn off the appliance
To correct, turn the appliance off and wait
one minute and turn the appliance back on.
If problem persists - call AccuTemp Service
Fig 6.A
Over-Temp Light
(Heat light will also be
illuminated in normal
operation)