Daily Maintenance 

Your Accuspray HVLP Gun is made from cast 
aluminum, and it contains aluminum components. 
Certain solvents containing Methylene Chloride and 
Trichloromethane are not chemically compatible with 
aluminum. If you are in doubt whether a coating or 
solvent is compatible, read the Material Safety Data 
Sheet, or contact your material supplier. 
 
It is very important to clean your gun and cup after 
every use. The fluid passage can be cleaned by 
adding a small amount of solvent to a clean cup, 
pressurizing the cup, and triggering the gun. Do this 
with the air cap removed so you may recapture the 
spent solvent for proper disposal. 
 
The air cap should be cleaned by soaking, or by 
using a soft brush. Never use a hard tool that may 
damage the air cap holes. Clean the air cap holes 
with a wooden tooth pick or pipe cleaner. The 
smallest amount of damage to the air cap holes can 
effect the spray pattern. 
 
Your gun and cup may be cleaned in a gun washer. 
Limit the time in the gun washer to a maximum of 5 
minutes. Some solvents may enter the through the 
air inlet fitting. This will not damage the gun, and the 
excess solvent may be blown out with air. 
 

Lubrication 

After every cleaning of the gun, you should lubricate 
the moving components. Lubricate with Accuspray 
Gun Lube P/N 91-170.  

 

Component Replacement 

With regular cleaning and lubrication, complete 
disassembly of your gun should seldom be required. 

 

 
 
 

When it becomes time for a complete overhaul, or a 
part requires replacement, please follow these 
instructions: 
 

General 

Close your air source down. Remove the air hose 
from the gun. Dispose of any unused paint, flush 
and clean the gun. 
 

Atomizing Set 

With the retaining ring and air cap removed, pull and 
hold the trigger, unscrew the fluid nozzle using your 
Accuspray Gun Wrench and remove the fluid nozzle. 
 
Release the trigger and unscrew the needle tip with 
your fingers. Remember to retract the needle when 
re-installing the fluid nozzle. 
 
To remove the needle shaft, unscrew and remove 
the needle adjustment screw and the needle 
adjustment spring. Pull the needle out of the gun 
with your fingers. If the needle does not pull out 
freely, loosen the packing nut. Your gun wrench will 
accomplish this with the trigger still attached to the 
gun. 
 

Trigger Removal 

Locate the 2 E-clip's on the side of the trigger. Slide 
them off with a flat-blade screwdriver. The trigger 
pivot pin (upper), and the trigger pin (lower) will now 
slide out. The trigger is now free to be removed. 
 

Packing Nut Spacer and Packing 

Unscrew and remove the needle adjustment screw 
and the needle adjustment spring. Pull the needle 
out of the gun with your fingers. If the needle does 
not pull out freely, loosen the packing nut. Remove 
the packing nut with your gun wrench. The 
compression spring, spacer, needle guide, and seal 
should fall freely from gun. If you experience 
difficulty with removal, remove trigger pin and firmly 
tap the rear of the gun on a block of wood. Then 
remove the seal with an o-ring pick or similar narrow 
instrument.  

 
 

Maintenance 

Содержание VMX

Страница 1: ...Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA SM VMX 2001 800 618 6860 or 440 498 9677 Fax 440 498 9815 VMX PORTABLE COMPRESSOR HVLP SYSTEM Owners Manual...

Страница 2: ...ollow the requirements of the Material Safety Data Sheet supplied by the coating manufacturer Use a respirator whenever there is a chance of inhaling sprayed material The mask must be compatible with...

Страница 3: ...rectly atomize your coating Over pressurizing wastes material increases overspray and works the unit harder than necessary Set Up Instructions Diagrams illustrating the following instructions are loca...

Страница 4: ...the atomizing air completely while adjusting fluid pressure This is done by turning the spray gun regulator to zero Trigger the gun fully open and hold spray gun parallel with the floor Increase flui...

Страница 5: ...5 5 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 6: ...6 6 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 7: ...counterclockwise turns from closed you will have full needle travel Please note that when closing down the needle adjustment screw when the needle travel has stopped further tightening will damage th...

Страница 8: ...8 8 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual Troubleshooting...

Страница 9: ...d lubrication complete disassembly of your gun should seldom be required When it becomes time for a complete overhaul or a part requires replacement please follow these instructions General Close your...

Страница 10: ...replacement of the valve stem cap will be covered later in this section The valve stem will pull out from the valve seat and out of the gun through the seal housing The valve seat can be removed from...

Страница 11: ...11 11 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual Maintenance...

Страница 12: ...k and clean cup gaskets after every use Lubricating cup gaskets with Accuspray gun lube will extend the life of the gasket and keep it sealing properly If using a 1 quart cup check the diaphragm and t...

Страница 13: ...13 13 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 14: ...14 14 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 15: ...15 15 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 16: ...16 16 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 17: ...17 17 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 18: ...18 18 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 19: ...19 19 Copyright 2003 Accuspray Application Technologies Inc Cleveland Ohio USA 800 618 6860 or 440 498 9677 Fax 440 498 9815 V M X Owners Manual...

Страница 20: ...ctive to an authorized Accuspray Service Center or to Accuspray to verify the claimed defect If the claimed defect is verified to be covered by this warranty Accuspray will repair or replace free of c...

Отзывы: