background image

REPLACING THE BATTERY AND MASTER RESET

When the display starts to dim or goes blank, it is time to 
replace the battery.  
If the display is not uniformly dim or blank, and appears to 
display “erroneous data”, do a Master Reset by pressing all  
3 buttons simultaneously for 3 seconds and then release. 
The display should go blank, then turn all segments on, then 
display 0 steps in Step Mode. 

Note:

 All the settings will return to their default setting values.  

If you need to change the battery, the settings will also revert  
to default settings.

CHANGING STEP FILTER SETTING 

While the JW200 PedometerEngine™ Step Sensor is extremely 
accurate, some people like to have the ability to filter out false 
steps.  Therefore, the unit has a variable setting step filter, to 
allow fine-tuning to your specific preferences. You can set the 
value to any value from 0 – 5 steps. For example, if the filter is 
set to “3”, the unit will wait to start counting steps until more 
than three steps have been taken in less than five seconds. 
Press and hold the S1 (MEMORY) button for 4 seconds. The 
screen will display a single digit. Press S3+ (MODE) or S3– 
(RESET) to change the Step Filter Setting. Press and hold S4 
(Memory) for 2 seconds to exit Deep Set Mode.

Note: 

The unit will save any changes and exit set mode after  

          30 second unattended.

18

19

17

23

20

21

22

OTHER SETTINGS 

The Step Filter setting is accessed through a special “deep 
set” mode. 

ACCUSPLIT products use a common setting procedure  
known as “S1- S2-S3-S4.” Here’s how it works:
Press S1 for 2 seconds: Enter the SET mode
Press S2: Change the field to be set
Press S3: Change the field value
Press S4 for 2 seconds: Exit the SET mode

Set Step Filter set point

STEP   TIME                             SET     

D

IGI

-

W

ALKER

XL

.COM

120

XL

M

S3-

S3+

S1,S2,S4

JW200

Can be set 

from 0-5 

steps

Battery

To replace the battery:
1.  Insert a coin into the slot on the  
  bottom of the case, and twist to  
  loosen the faceplate. Remove  
  faceplate and set aside.
2. Locate the battery holder as seen  
  on sketch. Pull out the old battery,  
  and push a new LR-44 battery into the holder,  
  with positive terminal (+) facing up.
3.  Snap faceplate back into place, hooking the bottom  
  two tabs first, then closing by pressing together at the  
  top two tabs.  

SPECIFICATIONS, FEATURES, and FUNCTIONS
Description of Functions

•  Counts Steps up to 99,999 then rollover.
•  Has a Total Memory for Steps that counts up to 99,999,999  
  steps, then rollover.
•  Counts Time spent in step activity, up to 999 Min 59 sec,  
  then rollover. Automatically counts whenever step activity  
  is occurring.
•  Has a Total Memory for Activity Time that counts up to  
  99,999 minutes, then rollover.
•  Adjustable Step Filter (default setting is 1 step, but can  
  be set from 0-5 steps) to increase step count  accuracy.

REGISTER NOW

 

Please return  

your AE120XLM Registration to  
the Repair Center address in the  
warranty, and we will let you know 
about future products. 

Email (preferred)
User

NO-PROOF-OF-PURCHASE LIMITED WARRANTY

Free service for first year of ownership;  

$12 fee for service thereafter. See label inside unit for date.  

See www.ACCUSPLIT.com/support for details

Battery, replacing . . . . . . . . . . . . . . . . . . 19-20

Current day’s results, viewing . . . . . . . . . . .11

Memory, resetting  . . . . . . . . . . . . . . . . . . . 15

Open your pedometer . . . . . . . . . . . . . . . . . 4

Safety Leash . . . . . . . . . . . . . . . . . . . . . . . 9-10

Setting up pedometer. . . . . . . . . . . . . . . . 6-11

Step Filter Setting, change. . . . . . . . . . . 16-18

TOTAL vs TRIP Memories . . . . . . . . . . . . 12-13

Wearing pedometer . . . . . . . . . . . . . . . . . . . 8

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

INDEX

16

Отзывы: