Practice Section 104003C Rev A    January 2014

 

 

WWW.ACCURATE.ORG

    PO BOX 1654  97075-1654    8687  SW HALL BLVD  97008      BEAVERTON OR  USA    503.641.0118     FAX 503.646.3903 

                                                             

This document contains proprietary information and is supplied for identification, maintenance, engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written 
permission of:  ACCURATE ELECTRONICS INC By accepting this document the recipient agrees to make every effort to prevent unauthorized use of this information. 

 

TONE-LOOPBACK FREQUENCY 

3.09

    Tone-loopback  frequency  is  selected  by  means  of  10-position  DIP 

switch (S3) located on the 104003C’s daughter pcb.  Only 1 switch position 
is required to select any 1 of 11 available frequencies.  The available loopback 
frequencies and settings of switch 

S3

 are summarized in Table 3. 

 

Table 3.

  Loopback Frequency Selection. 

FREQUENCY 

(Hz)

 

S3 SWITCH POSITION 

SET TO 

ON

*

 

2813 

All switch positions OFF 

2713 

2513 

2413 

1913 

1813 

1713 

1613 

1513 

1413 

1313 

10 

*all other S13 switch positions MUST be set to the OFF position. 

 

LOOPBACK LEVELS 

3.10

  Loopback levels of +16, +9, -16, or –23dB are selected via DIP switch 

S4

,  located  on  the  104003C’s  daughter  pcb.    Loopback  level  options  are 

described in paragraph 2.10; the various settings of switch 

S4

 are summarized 

in Table 4.  

Table 4.

  Loopback Level Selection. 

Loopback Levels 

Switch Positions 

S4-1 

S4-2 

+16dB 

Off 

Off 

+9dB 

Off 

On 

-16dB 

On 

Off 

-23dB 

On 

On 

 

ALIGNMENT 

3.11

    This  alignment  subsection  is  divided  into  two  parts:    preliminary 

alignment  and  final  alignment  verification.    In  the  preliminary  alignment 
procedure, impedance options are selected, equalization is introduced into the 
receive  and  the  transmit  channel  (if  required),  and  gain  or  attenuation  is 
introduced  in  both  the  transmit  and  the  receive  channel  to  match  the 
transmission levels specified on the circuit level record (CLR) card.  In the 
final alignment verification procedure, the 104003C is placed into service and 
end-to-end  transmission  measurements  are  made.    If  the  measured  levels 
differ  from  those  specified  on  the  CLR  card,  the  front-panel  TX  and  RX 
LEVEL switches are adjusted to provide the specified levels. 

Note:

  Two condensed preliminary alignment procedures (Figures 6 and 8) 

and two condensed final alignment verification procedures (Figures 7 and 
9) may be used to facilitate alignment of the 104003C module.

 

PRELIMINARY ALIGNMENT 

3.12

  Refer to the CLR card for the required facility port and terminal port 

impedances.    In  general,  the  1200-ohm  option  is  used  to  interface  loaded 
cable,  the  600-ohm  option  is  used  to  interface  nonloaded  cable,  carrier, 
station apparatus, or SF signaling units, and the 150-ohm option is used to 
interface  short  segments  of  nonloaded  cable  in  applications  where  a  small 
degree  of  slope  equalization  is  required.    Use  S2  (Main  Board)  to  set  the 
facility  port  impedance  and  S4  (Main  Board)  to  set  the  terminal  port 
impedance. 

FIGURE 5.  

Module Switch Locations. 

 

Содержание 104003C

Страница 1: ...DX loopback and other signaling schemes that require a dc path 1 05 The 104003C provides loopback toward the facility for remote testing of the circuit Loopback may be tone or dc activated In the tone...

Страница 2: ...3C are center tapped to derive simplex leads allowing this module to be applied to circuits employing DX loopback or other dc signaling schemes Figure 4 LOOPBACK 2 07 The loopback feature of the 10400...

Страница 3: ...described in paragraphs 3 6 through 3 10 Locations of these switches on the module s front panel and printed circuit boards are shown in Figure 5 CHANNEL OPTIONING 3 06 Levels The front panel Gain Los...

Страница 4: ...ck Levels Switch Positions S4 1 S4 2 16dB Off Off 9dB Off On 16dB On Off 23dB On On ALIGNMENT 3 11 This alignment subsection is divided into two parts preliminary alignment and final alignment verific...

Страница 5: ...the difference in dB between the equalized receive input level or the specified receive input level if equalization was not used and the specified receive output level to determine how much gain or lo...

Страница 6: ...tone at the specified level Request that personnel at the distant facility side receive location measure and record the 1000Hz level D Determine the difference in dB between the distant facility side...

Страница 7: ...d to Accurate for repair or replacement as directed below We strongly recommend that no internal component level testing or repairs be attempted on the module Unauthorized testing or repairs may void...

Страница 8: ...output level paragraph 3 20 4 Disconnect the TMS Connect the properly terminated TMS receive to the TX IN MON jack and insert an opening plug into the TX IN jack Request that personnel at the distant...

Страница 9: ...0Hz and 3000Hz signal levels Divide this difference by 2 and referring to table 2 set front panel RX EQL switch for the required nearest but lower amount of equalized gain Nonloaded cable Determine th...

Страница 10: ...tches S2 and S4 properly set Level Equalizer switches front panel RX LEVEL and RX EQL properly set Replace module and re test Transmit Level Connect properly terminated TMS receive to TX OUT jack Inse...