• Never disassemble the device. In the event of a fault, please contact your retailer.  

• Do not expose this device to high temperatures and protect it from water and high humidity.  

• Protect the device from severe shocks or excessive vibrations. 

• For this device, only use accessories and spare parts that comply with the technical information.  

Risk of voltage damage  

The manufacturer is not liable for voltage damage through the use of an improper power adaptor. 

 

3. 

Packing List  

CO2 Monitor Unit  

USB cable for Power (standard USB power adaptor plug required)  

User Manual 

 

4. 

Warnings 

• The provided USB cable can be ONLY used as power supply for this device. 

• Do not disassemble this device or change internal wiring. 

• Do not store or use this product in high temperature, high humidity, flammable, explosive or strong 
electromagnetic environment. 

• Do not restore factory defaults too often, as it will cause program damage. 

• Keep the device away from your face, as the exhaled carbon dioxide will affect its accuracy. 

 

5. 

Features at a Glance 

Large Display 

Touch Button Operation 

15° Bevel Design, Easy to Read 

Low Drift NDIR Sensor, Long Lifespan  

Audible and Visual Alarm 

Temperature, Humidity and CO2 Monitor, Date and Time Display 

Auto-Calibration and Manual Calibration 

Wall mount or desktop 
 

 

Содержание CO2-6000

Страница 1: ...power supply at any time The power socket should be installed near the device and should be easily accessible as the mains cable plug is used to disconnect the device from the power supply To disconne...

Страница 2: ...r plug required User Manual 4 Warnings The provided USB cable can be ONLY used as power supply for this device Do not disassemble this device or change internal wiring Do not store or use this product...

Страница 3: ...3 6 Overview 7 LCD Display...

Страница 4: ...menu bar press arrow buttons to cycle and switch function options press MENU to switch each option in turn until exit Notice if the device is not operated in 30 seconds the menu bar will disappear an...

Страница 5: ...Mode Default alarm values are 800ppm and 1200ppm for both modes 13 Alarm Indicator In the Human mode the GREEN light is on when the CO2 reading is lower than the low alarm value the YELLOW light is on...

Страница 6: ...and Date 16 Calibration Before calibration run this device for at least 20 minutes with window open or in an outdoor environment with backup battery to reach an atmosphere with 400ppm CO2 Wait until...

Страница 7: ...cy 0 3000 ppm 50ppm 5 of reading 3000 ppm 7 of reading Temperature compensation 0 2 of reading per C reference of 25 C Response time 2 minutes for 63 of step change or 4 6 min for 90 step change Warm...

Страница 8: ...ials properly according to their type such as paper or cardboard Contact your local waste disposal service or environmental authority for information on the proper disposal Do not dispose of electroni...

Страница 9: ...9 This page has been intentionally left blank...

Страница 10: ...10 This page has been intentionally left blank...

Страница 11: ...11 This page has been intentionally left blank...

Страница 12: ...12 This page has been intentionally left blank...

Отзывы: