ACCUR BA-100 Скачать руководство пользователя страница 4

Operation instruction and notes

1

SDI/HDMI output standard testing pattern

Step2

.

Link BA-100 SDI OUT and SDI IN on the tested equipment 

by coaxial cable, switch the signal channel of the device to SDI 
mode, the tested pattern displayed.
Step3

.

Press the key“SMPTE”

“SDI OUT”signal output switches 

between high denition(1080 50i)and standard denition(576 50i).

SMPTE RP 219 SDTV/HDTV

Step1

.

Plug the AC/DC adapter into the “      ”input in BA-100

SDI monitor color calibration

SDI

Monitor

SDI

 

cable

USB

cable

USB

 

cable

Meter

BA-100

PC

Hardware equipment connection diagram

2

Calibration PC System Requirements

:

● 

Windows® Vista™ or later with latest operating system updates 

installed (recommended: Windows 7® or later)

Содержание BA-100

Страница 1: ...ice Note Product picture dimensions are for reference only Detailed information is in accordance with the nal product All the information are carefully checked if any printing or translation errors oc...

Страница 2: ...5 calibration software Attention 1 Use the assorted power adaptor 2 Away from heat keep ventilated 3 Connecting plug equipment pay attention to esd protection 4 When equipment is on operation note th...

Страница 3: ...hort press Press for 3s SMPTE Red LED turn on LUT OFF cyclic switching 576 50i 1080 50i 1 2 3 4 5 6 2 Interface functions description HDMI output SDI input SDI output USB data controlling port DC 12V...

Страница 4: ...he key SMPTE SDI OUT signal output switches between high de nition 1080 50i and standard de nition 576 50i SMPTE RP 219 SDTV HDTV Step1 Plug the AC DC adapter into the input in BA 100 SDI monitor colo...

Страница 5: ...input distance the testing of the breakdown point real testing data L 2 5CFB L 2 5CHD L 3CFB L 4CFB SMPTE 344M SMPTE 292M SMPTE 424M SD SDI 540Mb s HD SDI 1 5Gb s 3G SDI 3 0Gb s M 139 54 36 168 66 46...

Страница 6: ...2 0 6 678ps 649ps 85ps 83ps 94ps 90ps 0 09UI 0 06UI 0 22UI 0 48UI 0 05UI 0 11UI Note Eye diagram testing use the SDI cable from Canare L 3C2VS length is 300mm NOTE the above technical parameter are a...

Страница 7: ...ng right button of the mouse Step2 Copy the LUT le From_SLog2 SGumut_To_LC 709Type A cube under the root directory of RgLutLoadTool161215 Step3 Double click RgGenBoxLoad3DLut exe to pop up the loading...

Страница 8: ...ion well or not and whether SDI signal in out is connected well or not 3 When calibration Source Displays can not set well a Please check USB cable connection well or not b Please check whether the BA...

Отзывы: