Formal Test
1. Press the ON/OFF button for 1 second to turn on the device and enter
the
“ALCO” mode.
2.
In the “ALCO” mode, press the ON/OFF button to activate the warming of
the sensor.
“PH” will flash for a few seconds (it will take longer in a cold
environment).
3.
“tESt” will flash for about 30 seconds with beep tones when the device is
ready to test. Please carry out the measurement within this period. User can
press the left-
key to terminate the test and return to the “ALCO” mode.
4. Blow continuously through the mouthpiece for about 6 seconds. A long
beep tone sounds continuously while blowing. Stop blowing when the beep
tone stops. “Anly” will flash while the analysis is being carried out. Two short
beep-sounds will be heard when the sample has been taken successfully.
The result will be shown on the display.
The reading range is 0.000 - 0.400%BAC
.
“HI” will be shown if the reading is higher than 0.400%BAC.
5. User can press the ON/OFF key for another test.
“PH” & “tESt” flashes, please repeat step 3 & 4.
The test reading will remain on the display for 3 minutes.