background image

Menus and Buttons

Part One

15

2.0 Menus and Buttons 

2.1   Main Task Screen
Once turned on, the machine will self-analyze for 5 seconds. You will first see the “AccuBANKER
AB6000” message on the screen and then the Main Task menu which will look like this:

The various fields in the menu are described here:

The currency type, in this case, US dollars.
The denomination of the bills to count.
The units counted.
The batch quantity selected.
This will let the user know how many units have been counted during all the counting operations.
The amount of the counted bills. This code will appear when a specific bill denomination is selected. 

Initial screen

Cur: USD

Uni: 0

Total: #

Value: 0

Cur:USD

Den:

Uni:

Bat:

Total:

Value:

Den:

Bat:

Содержание AB6000

Страница 1: ...user s guide because your money counts user s guide 2 manual de usuario 29 AB6000 digital bill counter with computer connectivity...

Страница 2: ...Hilton Trading Corp All Rights Reserved Before turning the power on please make sure that there are no objects obstructing the operation of the rollers and wheels When operating the unit please wait...

Страница 3: ...ONE 1 0 GENERAL CONTROLS AND PARTS 1 1 SPECIFIC CONTROLS 2 0 MENUS AND BUTTONS 2 1 Main Task Screen 2 2 Control Panel 2 3 Settings Menu 3 0 OPERATIONS 3 1 Counting 3 2 Adding 3 3 Batching 3 4 Counter...

Страница 4: ...ROUBLESHOOTING OPERATIONAL PROBLEMS 4 1 Avoiding Problems 4 2 Jamming 4 3 When Counting Numbers Are Wrong 4 4 Additional Recommendation 5 0 SPARE PART REPLACEMENT 5 1 Replacing the Fuse 6 0 ERROR MESS...

Страница 5: ...n banks casinos supermarkets movie theaters retail locations and many other environments where counting cash is an everyday task The model main features are given below AB6000 Overview sturdy well equ...

Страница 6: ...ng the machine It is composed by two major parts Part One Basic instructions Part Two Instructions on how to handle operational problems specifications etc Before using the machine read this manual th...

Страница 7: ...nce is subsequently used Only use the cable provided with the unit The use of other cables may result in electric shock fire or cause serious damage to the unit Do not operate the unit in areas with h...

Страница 8: ...into the outlet contact your electrician to replace the outlet Do not try to defeat the safety purpose of the grounding type plug Never push objects of any kind into the unit through any openings sin...

Страница 9: ...If any item is damaged or missing contact the place where the unit was purchased Box Contents Box Contents 9 Auxiliary Counting Screen Power and Computer Cables Use the cable provided with the produc...

Страница 10: ...has been factory set and tested to ensure proper feeding of the bills However when the unit presents recurrent chain and double note errors and these are not due to the condition of the counted bills...

Страница 11: ...the approximate position of the sensors C Emergency Stop Feature In the event of an emergency this feature can be activated manually by depressing the red Emergency Stop Button located on the upper ri...

Страница 12: ...s and Parts Part One 1 0 General Controls and Parts Counting Guides Hopper Folding Handle Plastic Frontal Platform Stacker Emergency Stop Button Optical Sensors Control Panel SEL Del Den T Cl SE r 100...

Страница 13: ...Part One General Controls and Parts 13 Auxiliary Screen Port Computer Port Power Inlet ON OFF Switch Hopper Adjustment Screw Fuse Box Auxiliary Counting Screen 15 15...

Страница 14: ...Specific Controls 14 Part One AB6000 1 1 Specific Controls Main Task Screen Menu Den Speed Clear Select Arrows Numbers 0 9 Restart 9 Menu Den Speed Select RESTART 1 2 3 4 5 6 7 8 9 C 0 Clear...

Страница 15: ...various fields in the menu are described here The currency type in this case US dollars The denomination of the bills to count The units counted The batch quantity selected This will let the user kno...

Страница 16: ...The user gains access to all of the unit Menu Access settings menu to change options Den This button will change the denomination setting Speed Changes speeds of counting Clear Clears total count and...

Страница 17: ...Select the batch number 1 999 This button is designed to Stop the counting operation at any given moment Resume the stopped counting operation In Manual mode to start the counting operation AccuLOG Co...

Страница 18: ...ng the Select button you can cycle between USD US dollars or NO no specific currency Selecting NO will cancel all detection systems even if these are ON Infrared detection system By pressing the Selec...

Страница 19: ...puter communication It is necessary to have it ON in order to use the AccuLOG software When using the unit without a computer turn this function OFF By pressing the Select button cycle between ON and...

Страница 20: ...estart to exit this menu and return to settings Menu vailable levels By pressing the Init Level button all levels will be reset to factory condition View Data Shows the user the following unit info 1...

Страница 21: ...a Units Do not enter any specific bill denomination Place bills on the hopper Once counted press the Select button to add them Total total units count shown at the bottom of the Main Task Screen b Am...

Страница 22: ...e available Refer to the SPEED setting on page 19 to learn how to choose the desired counting speed 3 6 Computer connectivity via AccuLOG Using the AB6000 bill counter together with the AccuLOG softwa...

Страница 23: ...r supervisor comptroller use only We recommend the password to be changed right after loging in for the first time This can be done by opening the Password menu and selecting the Change password optio...

Страница 24: ...option 6 The task bar in the AccuLOG presents 3 menus a PRINT this menu gives the user the option to print the current session or to pick a date and a specific session to print The printing will be do...

Страница 25: ...placement of the bills in the hopper If jamming occurs turn the machine OFF Carefully remove with a wood piece or a pencil the bills stuck in the system Check for proper tightness of the Hopper Adjust...

Страница 26: ...tion against risk of fire replace only with a fuse of the same type and rating 5mm x 20mm 2 0A 250V Procedure using a flat screwdriver remove the fuse box from the unit figure A This part holds two fu...

Страница 27: ...USA support Clean the dust and restart the unit Contact AccuBANKER USA support Contact AccuBANKER USA support Check the computer connectivity cable Press Start Stop to continue Remove the half notes...

Страница 28: ...lls 110mm X 50mm 185mm X 90mm Thickness of Countable Bills 0 07mm 0 20mm Main Unit Display Blue L CD with energy saver feature Auxiliary Counting Screen 4 small and 6 large digits red LED screens Coun...

Страница 29: ...los rodillos y ruedas receptoras de billetes antes de encender la m quina Encienda y espere 5 minutos antes de operarla para que el sistema ultravioleta alcance su m xima potencia AccuBANKER y su log...

Страница 30: ...PRIMERA SECCI N 1 0 CONTROLES Y PARTES GENERALES 1 1 CONTROLES ESPEC FICOS 2 0 MEN ES Y BOTONES 2 1 Pantalla Central de Tareas 2 2 Panel de Control 2 3 Men de Ajustes 3 0 OPERACIONES 3 1 Conteo 3 2 S...

Страница 31: ...CCI N 4 0 CORRECCI N DE PROBLEMAS DE OPERACI N 4 1 Prevenci n de Problemas 4 2 Atascamiento 4 3 Cuando el Conteo es Incorrecto 4 4 Recomendaci n Adicional 5 0 REEMPLAZO DE PARTES DE REPUESTO 5 1 Reemp...

Страница 32: ...a labores de conteo en bancos casinos supermercados cines establecimientos de venta al detalle y cualquier otro negocio en el que se requiera contar dinero diariamente Las caracter sticas principales...

Страница 33: ...la m quina Consiste de dos secciones principales Primera Secci n Instrucciones b sicas Segunda Secci n Instrucciones para la soluci n a problemas de operaci n etc Lea este manual y familiar cese con l...

Страница 34: ...ctrica fuego o da o irreparable a la unidad No operar esta unidad en reas con altas temperaturas o excesiva humedad ya que puede resultar en un mal funcionamiento de la misma Precauci n Cuando desench...

Страница 35: ...producto no deber ser puesto en un compartimiento que no tenga la ventilaci n apropiada Este producto deber ser operado utilizando el voltaje correcto indicado en el manual de usuario Si no est segur...

Страница 36: ...t culo falta o est da ado contacte al concesionario donde adquiri la unidad Utilice nicamente el cable que viene con la unidad El uso de otro tipo de cables el ctricos puede resultar en descarga el ct...

Страница 37: ...r la calibracion si los billetes son contados con dificultad gire el tornillo en direcci n a las agujas del reloj para incrementar la abertura de alimentaci n Si la unidad muestra los mensajes chain n...

Страница 38: ...nidad presionando el bot n rojo de parada de emergencia ste se encuentra en la parte superior derecha de la unidad Un indicador luminoso LED se encender cuando la funci n est encendida Una vez presion...

Страница 39: ...s Generales Gu as de Conteo Alimentador Asa Retr ctil Plataforma Pl stica Frontal Bandeja Receptora Bot n de Parada de Emergencia Sensores pticos Panel de Control 39 Controles y Partes Generales SEL D...

Страница 40: ...uerto para la Pantalla Auxiliar Puerto para la Computadora Toma de Alimentaci n Interruptor ON OFF Tornillo de Ajuste del Alimentador Caja de Fusibles Pantalla Auxiliar de Conteo Controles y Partes Ge...

Страница 41: ...en Denominaci n Speed Velocidad Clear Borrar Select Seleccionar Arrows Flechas N meros 0 9 Restart Iniciar Reiniciar 9 Menu Den Speed Select RESTART 1 2 3 4 5 6 7 8 9 C 0 Clear Primera Secci n 1 1 Con...

Страница 42: ...je AccuBANKER AB6000 Luego aparecer la Pantalla Central de Tareas que lucir as Descripci n de los campos en la Pantalla Central de Tareas Tipo de moneda en este caso d lares de los Estados Unidos de A...

Страница 43: ...leccionar la denominaci n deseada Speed Permite seleccionar la velocidad de conteo deseada Clear Borra el conteo total y el valor Lleva a la pantalla principal Menu Den Speed Clear Primera Secci n Men...

Страница 44: ...dora cuando se esta usando el programa er todas las posibles opciones de cualquier campo Seleccionar la cantidad de agrupaci n Este bot n esta dise ado para Detener la operaci n de conteo cuando sea d...

Страница 45: ...disponibles que son USD d lares americanos o NO ninguna moneda especifica Al seleccionar NO todos los sistemas de detecci n ser n anulados aun si estos est n encendidos Sistema de detecci n infr arojo...

Страница 46: ...den ver ambas opciones computadora comunicaci n con la computadora Es necesario tener este campo en ON encendido par a poder usar el programa AccuLOG Cuando no se use el progama debe estar en OFF apag...

Страница 47: ...lect para ver los 8 niveles disponibles Al apretar el bot n Init Level todos los niveles volver n a la condici n original de f brica Muestra al usuario la siguiente informaci n de la unidad 1 tiempo t...

Страница 48: ...agregarlas al campo Total total de unidades que se encuentra en la base de la Pantalla Central de Tareas b Cantidad ingrese la denominaci n deseada Coloque los billetes en el alimentador Una vez que s...

Страница 49: ...es por minuto Cuatro velocidades de conteo est n disponibles Para elegir la velocidad de conteo deseada vaya a la p gina 46 y busque el ajuste del campo SPEED 3 6 Conectividad con la Computadora v a e...

Страница 50: ...cuenta La opci n MASTER ha sido dise ada solo para el uso del supervisor o controlador Recomendamos que cambie la clave de entrada ingresando al men Password clave y seleccionando la opci n Change Pa...

Страница 51: ...enamiento en memoria de la sesi n y la inicializaci n de una nueva Save session Yes or No guardar la sesi n S o No Elija la opci n deseada 6 La barra superior de AccuLOG tiene 3 men es a PRINT imprimi...

Страница 52: ...ecto de los billetes en el alimentador En caso de atascamiento apague la unidad Retire el billete atascado con la ayuda de un palito o un l piz Verifique que el Tornillo de Ajuste de Alimentaci n de B...

Страница 53: ...ntes de empezar Para una protecci n continua contra riesgo de fuego reemplace solamente con un fusible del mismo tipo y tolerancia 5mm x 20mm 2 0A 250V Procedimiento con un desatornillador plano retir...

Страница 54: ...guir contando Retire los billetes rotos fraccionados Presione Start Stop para seguir contanto Ocasionado a veces por billetes viejos Verifique el estado de los mismos Si esta no es la causa Retire los...

Страница 55: ...Aceptable de Billetes 110mm X 50mm 185mm X 90mm Grosor Aceptable de Billetes 0 06mm 0 12mm Pantalla de Conteo de Billetes LCD verde con funci n de ahorro de energ a Pantalla de Conteo Auxiliar pantall...

Страница 56: ......

Отзывы: