background image

 

 

13 

12. Storage and maintenance instructions 

(1) Please fully charge the machine before storing it.   

(2) Turn off all power buttons.   

(3) To preserve the battery liftspan, please use and recharge at least once every 6 

months. 

(4) Ensure proper ventilation while in use or store and keep away from any combustible 

materials or gases. Do not stack anything on top of the unit in storage or in use. 

Inadequate ventilation and/or improper storing may cause damage to the unit. 

(5) Avoid exposing the product to rain or using the product in humid environment.     

(6) Use and store the product in a clean and dry environment. 

(7) Keep this product away from children and pet. 

(8) Wring the cloth with water and wipe it clean In case of dirt. 

 

13. Declaration 

●Some changes may be made to the appearance and specifications without prior notice 

due to the improvement of the product. 

●Our company shall not be liable for any damage caused by force majeure such as fire, 

typhoon, flood, earthquake or the user's intentional negligence, misuse or other abnormal 

conditions. 

●No compensation shall be made for the failure of non standard connector/accessories. 

●Our company will not bear all responsibilities if the damage is caused by not operating 

the product according to the use method in the operation manual. 

●This product is not suitable for use on the relevant equipment or machines involving 

personal safety, such as atomic energy devices, aerospace devices, transportation 

devices, medical devices, etc., or the equipment or machines that must be highly reliable 

in electricity. If we use this product on the above-mentioned equipment or machine, we will 

not be responsible for personal accident, fire accident or wrong action of the machine and 

equipment caused by the failure of this product. 

 

14. Common faults and troubleshooting 

If this product is unable to charge or power other equipment, please check according to 

the following steps. 

(1) Ensure that the power button is on and the power button light is always on(green). 

(2) Make sure the DC ON / OFF button and AC ON / OFF button are on. 

(3) Check whether the left of battery capacity is more than 5%. If the left of battery 

Содержание AC200P

Страница 1: ...AC200P Portable Power Station User Manual ...

Страница 2: ... display 04 5 The operation steps of user friendly touch screen display 04 6 Charging the product 07 7 Discharging 09 8 Application scenario 09 9 Examples of loads 10 10 Estimation of charging time 10 11 Specification 11 12 Storage and maintenance instructions 13 13 Declaration 13 14 Common faults and troubleshooting 13 15 FAQ Frequently Asked Questions 14 ...

Страница 3: ...d when using this product near children 6 Please confirm the rated specification of your load and do not use it beyond the specification 7 Do not place the product near heat sources such as electric furnace and heaters 8 Not permitted on aricrafts because the battery capacity exceeds 100Wh 9 Do not touch the product or the plug in points if your hands are wet 10 Check the product and accessories p...

Страница 4: ...put 1 6 User manual 1 7 Warranty card 1 8 Certificate 1 9 12V 25A aviation plug to XT60 output 10 12V 25A XT60 to spc45 output 11 12V 24V lead acid battery charging cable XT90 to Red Black clamp input 12 Connector for dual AC adapter Female 7909 to XT90 13 Trolley 14 Carry bag 1 Standard accessories included 2 Options not included buy separately from seller The picture is for reference only take t...

Страница 5: ...lay 5 USB output x 4pcs 6 US AC output x 6pcs EU UK AC output x 2 pcs 7 12V 25A output 8 12V 3A output 9 PV car input port 10 AC adapter input port 11 Wireless charging x 2pcs 12 Note AC stands for alternating current DC stands for direct current PV stands for photovoltaic solar charging Car stands for automobile electric energy ...

Страница 6: ...n off the DC AC output 4 How to use the touch screen Interaction LCD screen Information Vision supports below functions 1 Real time display of voltage current power temperature and state of charge and discharge 2 The user can adjust the output voltage frequency charging mode power consumption mode and time information according to the setting column 3 Support energy saving and enable Super ECO mod...

Страница 7: ...ings button in the main interface Figure 2 to enter the setting interface as follows Figure 3 Warm tip Please enter the setting interface to set the date and time according to the local time zone and check the output voltage frequency and other parameters for the first time The default JP output 100V 50Hz US output 120V 60Hz EU output 230V 50Hz UK output 230V 50Hz DC Input Source PV solar ECO Mode...

Страница 8: ...r the page Figure 4 Click the Product Info button you can view the product model control software version monitoring software version BMS monitoring software version and display software version in turn Click the Inverter Charger Info button you can view the PV Car operation and the adapter operation status DC out operation and AC out operation in turn which can also Figure 2 Figure3 ...

Страница 9: ...the fault button to view the corresponding fault information Fault History is retained up to 10 years if not manually cleared 4 Return to the main interface and click the fault button Figure 1 to view the current fault information the fault button will display orange if there is a fault click to enter the corresponding fault information then the gray light will turn into orange 6 Charging the prod...

Страница 10: ...the car lighter port Press the power button and connect it to the cigarette lighter port through the car charging cable Enter the setting interface as shown in Figure2 through the display screen to set DC input source to car mode The product can be charged with 8 2A maximum current 4 Charging Mode 4 From a generator gasoline propane or diesel Connect the AC adapter input to the generator and the o...

Страница 11: ...lighter port USB and type C output first press the power button then enter the main interface through the touch screen click the DC ON OFF button and confirm Turn off these output and also click the DC on off button and confirm 2 Turn on AC output first press the power button then enter the main interface through the touch screen click the AC ON OFF button and confirm Turn off these AC output port...

Страница 12: ...put and then it will automatically start twice at an interval of 20s If there is still an overload over current or short circuit alarm the output will be locked and it needs to be manually troubleshooting and then restart If the output stops repeatedly after restart please stop using it immediately only after troubleshooting or contact the seller or maintenance agent for help 4 When the battery po...

Страница 13: ...ed current 25A Overload power 330W load 2S Short circuit protection yes DC12V 10A output Rated voltage 12V Rated current 10A Overload power 120W 2s Short circuit protection yes DC12V 3A output Rated voltage 12V Rated current 3A Overload power 40W 2S Short circuit protection Yes USB output Rated voltage 5V Maximum current 3A Short circuit protection Yes Type C output Fast charging type PD2 0 60W Ma...

Страница 14: ... do not want this function please unplug the PV charging head after full charge 2 It supports charging while discharging and does not support UPS function Battery Pack Rated capacity 2000Wh 40Ah Voltage 41 5V 58 4V Short circuit protection yes Output overcurrent protection 70A Discharge high temperature protection 65 149 Recovery of discharge high temperature protection 55 131 Charging high temper...

Страница 15: ...he user s intentional negligence misuse or other abnormal conditions No compensation shall be made for the failure of non standard connector accessories Our company will not bear all responsibilities if the damage is caused by not operating the product according to the use method in the operation manual This product is not suitable for use on the relevant equipment or machines involving personal s...

Страница 16: ...ot recommended to use more than 1400W power The starting power of refrigerator air conditioner and electric drill is generally 5 7 times of the nominal power which is easy to trigger AC overload Can two products be used in parallel No Can I use third party solar panels You can use any solar panels available as long as they have MC4 connectors and when wired together the voltage is between 35V to 1...