Accu-Scope EXC-500 Скачать руководство пользователя страница 21

 CATALOG #

DESCRIPTION

500-2SBS

Dual viewing head section for side by side observation, LED pointer unit 

with power adapter, (1) binocular viewing head and (2) WF10x/22mm 

focusing eyepieces

500-2FTB

Dual viewing head section for front to back observation, LED pointer unit 

with power adapter, (1) binocular viewing head and (2) WF10x/22mm 

focusing eyepieces

500-5SBS

Five viewing head unit for side by side observation, LED pointer unit with 

power unit, (4) binocular viewing head and (8) WF10x/22mm focusing 

eyepieces

O-2005-35

0.35x c-mount adapter for 1/3" chip sensors, focus adjustable

O-2005-5

0.50x c-mount adapter for 1/2" chip sensors, focus adjustable

O-2005-65

0.65x c-mount adapter for 2/3" chip sensors, focus adjustable

500-2005-1

1x c-mount adapter (no lens)

500-2000

Photo tube, 23.2mm I.D.

500-2000-E

Photo/video intermediate attachment with photo tube for use with 

ergonomic binocular viewing head (CAT# 500-3155-BE)

Viewing Heads

500-3155

Binocular viewing head, 30

°

 inclined, IPD 47 - 78mm

500-3155-BE

Ergonomic binocular viewing head,  inclination from 5º to 35

° (

an optional 

photo/video port is available - see camera adapters)

500-3158

Trinocular viewing head, inclined 30°, IPD 47 - 78mm,  rotatable 360°, 

Viewing split:  100% T / 0% B; 20% T / 80% B; and 0% T / 100% B

500-3158-TE

Ergo Trinocular viewing head, adjustable 0° to 35°, IPD 47 - 78mm,  

rotatable 360°, Viewing split:  100% T / 0% B; 20% T / 80% B; and 0% T / 

100% B

500-NP

Sextuple nosepiece with analyzer slot

500-NP-PG

Nospiece plug for analyzer slot

500-NP-SP

Nospiece spacer to lower nosepiece by 20mm

500-3113

WF 10x/22mm focusable eyepiece with diopter adjustment and roll down 

eyeguard (each)

500-3112

EWF 12.5x/16mm focusable eyepiece with diopter adjustment and roll 

down eyeguard (each)

131-10-15

WF15x eyepiece with built-in diopter adjustment, 16mm field of view. 

Eyepiece accepts a 20mm reticle.

131-10-20

WF20x eyepiece with built-in diopter adjustment, 12.5mm field of view. 

Eyepiece does not accept a reticle.

500-3131-SR

Eye cushion (small ring) for WF10x/22mm eyepieces

500-3131

Roll down eyeguards (pair)

Eyepieces & Eyeguards

TEACHING HEAD CONFIGURATIONS 

(Does not include main microscope)

Camera and Video Adapters

Nosepiece

EXC-500 MICROSCOPE SERIES 

ADDITIONAL ACCESSORIES & PARTS

ACCU-SCOPE

®

 

73 Mall Drive, Commack, NY  11725  •  631-864-1000  •  www.accu-scope.com 

2

1

Содержание EXC-500

Страница 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com EXC 500 MICROSCOPE SERIES...

Страница 2: ...GRAMS 4 6 ASSEMBLY DIAGRAM PROCEDURE 7 DETAILED ASSEMBLY 8 10 ADJUSMENT OPERATION POWERING ON 11 ILLUMINATION 11 SPECIMEN SLIDE 11 STAGE STAGE TENSION 11 INTERPUPILLARY DISTANCE 12 LIGHT PATH 12 FOCUS...

Страница 3: ...nent including eyepieces objectives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persis...

Страница 4: ...ty Careful quality control procedures ensure each microscope is of the highest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded EPE foam container Do not d...

Страница 5: ...ower Objectives 2x 4x Fine Focus Adjustment Knob Coarse Focus Adjustment Knob Focus Tension Adjustment Knob Condenser Focusing Knob on both sides Illuminator On Off Button Illuminator Adjustment Knob...

Страница 6: ...h Selector Knob Condenser Set Screw ECO Light Control Button Field Aperture Diaphragm 3mm Lamp Housing Set Screw LED Connection Port Power Cord Receptacle Fuse Holder Under Power Cord Receptacle On Of...

Страница 7: ...bled by our factory technicians at our New York facility prior to shipment Should you need to disassemble assemble your microscope in the future please follow the instructions outlined below When asse...

Страница 8: ...nch Position the condenser with the centering pin facing toward the back of the dovetail slider Slide the condenser into place and wiggle it to ensure the positioning pin is engaged Gently retighten t...

Страница 9: ...Viewing Head Fig 7 Using the Hex wrench loosen the lock screw Position the viewing head above the dovetail opening as shown and with it tilted slightly down on the right slide the dovetail under the...

Страница 10: ...he LED Lamp Housing Fig 11 Using the Hex wrench loosen the lock screw for the LED lamp housing Align and install the lamp housing with the opening in the back of the stand as shown Retighten the lock...

Страница 11: ...15 Push the left side of the Specimen Holder on the top of the stage place to open the holder Place your slide in and release the holder to allow it to close firmly against the slide Adjusting the Sta...

Страница 12: ...Where on the eyepiece tube lines up to the interpupillary scale then that is the number for the interpupillary distance Range 47 75mm Remember your interpupillary number for future operation NOTE The...

Страница 13: ...e image is in view refine the image to its sharpest focus by turning the fine adjustment knob Rotate the diopter collar to obtain the sharpest focus To obtain the same sharp image using your right eye...

Страница 14: ...st the center adjustment screws and move the specimen to the center of the field of view Open the field iris diaphragm gradually If the image is in the center all the time and inscribed to the field o...

Страница 15: ...for three 3 seconds Replacing the Fuses Fig 26 27 The fuse holder drawer is located underneath the AC power cord receptacle on the back of the microscope To replace the fuses turn the power off and un...

Страница 16: ...on control and upper limit stop to prevent accidental damage to slides all metal gears brass for fine focus gear Stand Cast alloy aluminum Stage Mechanical stage with GorillaTM glass insert and tensio...

Страница 17: ...ck stop position by swinging the objective correctly into the optical path Dirt or dust on the view field Dirt or dust on the lens eyepiece condenser objective collector lens or specimen Clean the len...

Страница 18: ...ged yellow Lamp intensity is too low Blue filter not used Adjust the light intensity by rotating the intensity control dial and or iris diaphragm Use daylight blue filter Image is too bright Lamp inte...

Страница 19: ...ower objective Slide upside down Cover glass is to thick Diopter adjustment is not set properly Turn the slide over so the cover glass faces up Use a 0 17mm cover glass Readjust the diopter settings a...

Страница 20: ...mm rotatable 360 Viewing split 100 T 0 B 20 T 80 B and 0 T 100 B WF 10x 22mm focusing eyepieces with eyeguards Reversed sextuple nosepiece NIS Infinity Corrected PLAN 4x 10x 40xR 100xR oil objectives...

Страница 21: ...on from 5 to 35 an optional photo video port is available see camera adapters 500 3158 Trinocular viewing head inclined 30 IPD 47 78mm rotatable 360 Viewing split 100 T 0 B 20 T 80 B and 0 T 100 B 500...

Страница 22: ...20xR NIS S Plan APO objective N A 0 50 W D 2 1mm 500 3175 SAPO 40xR NIS S Plan APO objective N A 0 75 W D 0 70mm 500 3176 SAPO 100xR NIS S Plan APO objective N A 1 30 W D 0 15mm 500 3221 PH 6 position...

Страница 23: ...er 3205 Immersion Oil Type A 1 4 oz Cargille 500 3301 Dust Cover nylon for EXC 500 500 3301 MV Dust cover teaching units F 1CFW 1CF FRAEN 1CFW 1 color fixed light intensity fluorescence illuminator 30...

Страница 24: ...rol pod power source See ScopeLED wavelengths below to select wavelengths SLAF OL1 ScopeLED collimating adapter for EXC 500 EXC 350 Specify wavelength required when ordering ScopeLED products 25 LM 75...

Страница 25: ...orkmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user...

Отзывы: