Accu-Scope DS-360 Скачать руководство пользователя страница 1

 

 

 

   

       MANUAL 

 

 

 

 

 
 

 

 
 
 
 

 

 

 

 

 

 

73 Mall Drive, Commack, NY  11725  •  631-864-1000 (P)  •  631-543-8900 (F) 

www.accu-scope.com  •  [email protected] 

DS-360 

DIASCOPIC STAND 

 

(CAT# 131-13-28) 

 

 

 

 

 

 

 

 

Содержание DS-360

Страница 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com DS 360 DIASCOPIC STAND CAT 131 13 28 ...

Страница 2: ...pic Stand ACCU SCOPE 73 Mall Drive Commack NY 11725 631 864 1000 www accu scope com 2 CONTENTS INTRODUCTION 3 UNPACKING AND COMPONENTS 3 ASSEMBLY 4 6 OPERATION 7 TROUBLESHOOTING 8 MAINTENANCE 9 SERVICE 9 WARRANTY 9 ...

Страница 3: ...lity Careful quality control procedures ensure each microscope is of the highest quality prior to shipment UNPACKING AND COMPONENTS Your DS 360 stand arrived packed in an environmentally friendly shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your stand if needed Avoid placing the stand with or without microscope in dusty surroundings or in high ...

Страница 4: ...ve the contents of the box and place on a secure flat surface 2 Place the DS 360 stand on a flat surface Included DS 360 stand with attached focus track and microscope mount plastic arm rest 180mm glass stage plate LED light power adapter controller AC line cord 3 Place the glass stage plate into position on the base 4 Align the slots in the arm rest to the silver buttons on the base and slide the...

Страница 5: ...to the back of the stand The thumb screw may need to be loosened to insert the LED light completely Tighten the thumb screw until snug but do not overtighten 6 Loosen the locking screw in the microscope mount and place your stereo microscope into the circular mount Tighten the locking screw until snug but do not overtighten ...

Страница 6: ...E 73 Mall Drive Commack NY 11725 631 864 1000 www accu scope com 6 7 Plug the adapter controller into the back of the LED light 8 Plug the AC line cord into the adapter controller Plug the other end into a suitable 110V AC receptacle ...

Страница 7: ...o adjust tension grasp both focus knobs and rotate in opposite directions until the desired tension is reached Turning the right focus knob clockwise and the left focus knob counterclockwise will increase tension 5 Adjust the mirror for specimen viewing The DS 360 is equipped with a two sided mirror one side is a polished mirror and the other side has a silver metallic frosted surface While lookin...

Страница 8: ...es Clean the specimen vessel Clean the glass stage plate Clean the eyepieces The focusing knob is not smooth The focusing knob is too tight Loosen it to a suitable position The image drifts out of focus during observation The focusing knob is too loose Tighten it to a suitable position The image appears very dark very bright or the specimen cannot be seen The rotating mirror is out of position The...

Страница 9: ...ial and workmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of one year from the date of invoice to the original end user purchaser This warranty does not cover damage caused in transit misuse neglect abuse or damage resulting from improper servicing or modification by other than ACCU SCOPE approved service perso...