3078-ZOOM STEREO MICROSCOPE SERIES 

 

 

 

 

ACCU-SCOPE

®     

                          

73 Mall Drive, Commack, NY  11725  •  631-864-1000  •  www.accu-scope.com 

7

 

OPERATION 

 

 

 

 

 

 

 

 

 

 

 

Setting Illumination For LED Models (Fig. 1) 

Turn the light adjustment knobs 

 and 

 as shown on 

the base in Fig. 3:  turn clockwise to increase 
brightness; counterclockwise to decrease brightness. 

 
 

Using the Black & White Stage Plate (Fig. 2 ) 

For instruments supplied with a Plain Focusing Stand 
or Pole Stand, the user can use either side of the Black 
& White Stage Plate.  For samples that are white or 
other bright colors, the black surface is typically facing 
up to help increase contrast of the image. For other 
darker colored samples, the white surface is 
recommended. 
 
To remove the plate or reverse it, press down on the 
supporting point (Fig 2) so the other side of the plate 
lifts up for removal/reversing. 

 
 

Adjusting the Rotation Tension of the  
Focus Adjustment Knob (Fig. 3) 

To adjust tension, hold

 

both left and right focus 

adjustment knobs

 

with both hands, hold the left knob 

(to prevent it from turning), and rotate the right knob 
clockwise to increase (tighten) or counterclockwise to 
decrease (loosen) the focus knob tension.  

After tension adjustment has been completed, always 
rotate both adjustment knobs in the same direction 

 
 

Adjusting Diopter Ring (Fig. 4) 

 

Set the diopter rings

 

of both eyepieces to “0” position. 

(Do this when users change, because different users 
will have different diopter settings.) 

Place an easy-to-observe specimen on the stage plate. 

Rotate the zoom knob

 

to the highest magnification, 

then turn the focusing knob

 

to focus the specimen.

  

Rotate the zoom knob

 

to the lowest magnification, 

looking only into the left eyepiece, adjust the diopter 
ring on left eyepiece to focus the specimen. Then 
repeat procedure for the right eyepiece.

 

 

 

 

 

Fig. 1 

Press Down 

Fig. 1 

 

Fig. 2 

 

Fig. 3 

 

Fig. 4 

 

Left 

Diopter 

Adjustment 

Ring 

 

Right 

Diopter 

Adjustment 

Ring 

 

Содержание 3078 Series

Страница 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com 3078 Series ZOOM STEREO MICROSCOPE MANUAL ...

Страница 2: ... Commack NY 11725 631 864 1000 www accu scope com 2 CONTENTS SAFETY NOTES 3 CARE AND MAINTENANCE 3 INTRODUCTION 4 UNPACKING AND COMPONENTS 4 COMPONENT DIAGRAMS 5 ASSEMBLY 6 OPERATION 7 9 SPECIFICATIONS 10 TROUBLESHOOTING 11 MAINTENANCE 12 SERVICE 12 WARRANTY 12 ...

Страница 3: ...cope NOTE Always plug the microscope power cord into a suitable grounded electrical outlet A grounded 3 wire cord is provided CARE AND MAINTENANCE 1 Do not attempt to disassemble any component including eyepieces objectives or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dir...

Страница 4: ...of the highest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if needed Avoid placing the microscope in dusty surroundings or in high temperature or humid areas as mold and mildew can form Carefully remove the microscope from the shipping...

Страница 5: ...5 631 864 1000 www accu scope com 5 COMPONENT DIAGRAMS continued Eye Caps Eyepieces Binocular Viewing Head Zoom Knob Lock Screw Focus Arm Post Focusing Knob C mount Adapter Focusing Ring Stage Clips Black White Stage Plate Lock Screw Trinocular Viewing Head 3078 PS Model Shown ...

Страница 6: ...bly When assembling the microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Lock Screw Focus Arm Stage Clip Black White Stage Plate Stage Binocular Trinocular Viewing Head Eyepiece C Type Camera C mount Camera Connection C mount Adapter NOTE Install the C mount Connection to the camera then install the camera onto the C mount Adap...

Страница 7: ...the Rotation Tension of the Focus Adjustment Knob Fig 3 To adjust tension hold both left and right focus adjustment knobs with both hands hold the left knob to prevent it from turning and rotate the right knob clockwise to increase tighten or counterclockwise to decrease loosen the focus knob tension After tension adjustment has been completed always rotate both adjustment knobs in the same direct...

Страница 8: ...em until the left and right fields of view coincide completely and you are able to see a complete circle Installing or Removing the Reticle Fig 6 Unscrew the reticle retaining ring from the eyepiece see Fig 6 NOTE be sure to clean the reticle with a soft lint free cloth or cotton swab dampened with a lens cleaning solution available at camera stores see p 3 Care Maintenance Insert the clean reticl...

Страница 9: ...on the monitor and adjust the Focusing Knob until the image is clear focused 7 Rotate the Zoom Knob to minimum magnification adjust the focusing ring on the C mount adapter until the image is clear focused 8 Rotate the Zoom Knob to maximum magnification to observe whether or not the image is clear focused If not repeat 6 and 7 above until image is clear focused Replacing the Fuse LED Models Fig 8 ...

Страница 10: ...m Total Magnification Visual Field mm Total Magnification Visual Field mm 0 8X 95 8X 25 0 12X 18 7 16X 12 5 1X 10X 10 0 15X 15 0 20X 10 0 1 25X 12 5X 16 0 18 7X 12 0 25X 8 0 1 5X 15X 13 3 22 5X 10 0 30X 6 7 2X 20X 10 0 30X 7 5 40X 5 0 2 5X 25X 8 0 37 5X 6 0 45X 4 0 3X 30X 6 7 45X 5 0 60X 3 3 3 5X 35X 5 7 52 5X 4 3 70X 2 8 Auxiliary Objectives Optical Data optional CAT Magnification Working Distanc...

Страница 11: ...n the surface of objectives Clear objectives Image is not clear while focusing Diopter adjustment is not correct Readjust diopter Focusing is not correct Readjust it The focusing knob is not smooth The focusing knob is too tight Loosen it to a suitable position The image is obscure because of the head slipping down during observation The focusing knob is too loose Tighten it to a suitable position...

Страница 12: ...rkmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of one year from the date of invoice to the original end user purchaser This warranty does not cover damage caused in transit misuse neglect abuse or damage resulting from improper servicing or modification by other then ACCU SCOPE approved service personnel This ...

Отзывы: