EtherHub-16 Quick Start Guide

2

2.  If you are making a connection to an end-node device (e.g., a PC or server), be sure that it has

a properly installed 10BASE-T network interface card.  Attach one end of a straight-through
twisted-pair cable to an standard port (Port 1 ~ 16MDI-X ) on the hub and the other end to the
RJ-45 port of the device’s network interface card.  When inserting an RJ-45 plug, be sure the
tab on the plug clicks into position, to ensure that it is properly seated.  Using the hub in a
stand-alone configuration, you can network up to 16 workstations.

3.  Port 16MDI can be connected to a networking device such as a another compatible hub or a

switch.  Run straight-through cable from Port 16MDI on this hub to a standard (

MDI-X

) port

on the other device.  (When attaching the hub to a bridge or router, verify the port type
implemented on these devices before connecting any cabling.)

Note: If necessary, you may also cascade from the MDI port on another device to the MDI-X on
this hub.  Limit the number of hubs cascaded together is four, and be sure you do not create
any loops in your network connections.

Connecting to an Ethernet Backbone

Thin Ethernet

 - Plug the BNC T-type connector into a BNC port on the hub, and use this port to

connect the hub to a 10BASE2 thin Ethernet trunk.  If the unit is at the terminal end of a trunk
segment, then connect a 50-ohm (

) terminator to the open end of the “T” connector.  If the BNC

port has no connection, plug in the T-type connector and lock both ends with a 50 

 terminator.

Thick Ethernet

 - Attach an AUI to 10BASE5 transceiver to the thick Ethernet trunk, and then run

an AUI drop cable (with 15-pin D-type connectors on both ends) between an AUI port of the hub
and the transceiver.  Note that the maximum length of an AUI drop cable is 50 meters (164 feet).

Fiber Optic

 - If you plan to use an AUI port for connecting fiber optic cable, attach a fiber optic

transceiver (MAU) to an AUI port, and then connect the transceiver to the fiber optic backbone.

To specify the port types used on the rear panel, position the switches as indicated below:

Port 2

Port 1

Switch

BNC

BNC

O N

2     3   4    

1

F

Also note that if your transceiver provides an SQE
(Signal Quality Error) test, then it must be disabled.

BNC

AUI

1     2     3    4    

O N

AUI

BNC

O N

1     2    3     4

AUI

AUI

O N

1     2    3     4  

Содержание EtherHub-16

Страница 1: ...artition and reconnection Hardware Installation The EtherHub 16 has 16 RJ 45 ports of which Port 16 can serve as either a standard port or a daisy chain port It also has two AUI BNC ports Use twisted...

Страница 2: ...and be sure you do not create any loops in your network connections Connecting to an Ethernet Backbone Thin Ethernet Plug the BNC T type connector into a BNC port on the hub and use this port to conn...

Страница 3: ...ments are necessary when connecting to any input voltage in the range marked on the rear panel System Configuration The EtherHub 16 provides standard RJ 45 ports for attaching end node devices such as...

Страница 4: ...at both ends of the cable use crossover cabling Note When Port 16MDI is used Port 16MDI X cannot be used BNC Port 10BASE2 This hub has two built in BNC transceivers i e BNC1 and BNC2 on the rear panel...

Страница 5: ...g supplied to the hub Collision Flashing Two or more devices are transmitting at the same time This is normal for an Ethernet network However if there are excessive collisions the network may be overl...

Страница 6: ...ce Solution Check the power source and attached cable If the problem cannot be resolved you may have to replace your unit s power supply Ask for dealer assistance Specifications Transmission Technique...

Страница 7: ...the user at his own expense will be required to take whatever measures are required to correct the interference You may use unshielded or shielded twisted pair 100 STP or UTP for RJ 45 connections War...

Страница 8: ...e conductor cord Maximum length of 15 feet Parallel blade grounding type attachment plug rated 15A 125V 240 Volts For UL Listed CSA Certified Cord Set North America Minimum 18 AWG Type SVT or SJT thre...

Страница 9: ...s durch berhitzung kommen 6 Versuchen Sie niemals dieses Ger t selbst zu warten da beim ffnen oder Abnehmen des Geh uses die Gefahr eines elektrischen Schlages besteht 7 Keine Gegenst nde auf das Ansc...

Страница 10: ...SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY Copyright Copyright 199...

Отзывы: