Quick Installation Guide

CheetaHub Power-3008N/3016N

2

3

Note

: If more than one hub with internal switching is used in the stack, switching

between stack segments will be managed by the unit highest in the stack, and

internal switching will be disabled for all other units.

These hubs provide a friendly design that simplifies installation and network

troubleshooting.  The following figure shows the components of these hubs:

 

Mounting the Hub

These hubs can be placed directly on your desktop or on any flat surface.
Before you start installing the hub, make sure you can provide the right operating

environment, including power requirements, sufficient physical space, and proximity

to other network devices that are to be connected.  Verify the following installation

requirements:
• Power requirements: 100 to 240 VAC (± 10%) at 50 to 60 Hz (± 3Hz).  The hub's

power supply automatically adjusts to the input voltage level.

• The hub should be located in a cool dry place, with at least 10 cm. (4 in.) of space

at the front and back for ventilation.

• Place the hub out of direct sunlight, and away from heat sources or areas with a

high amount of electromagnetic interference.

• Check if network cables and connectors needed for installation are available.

Stacking Hubs on a Flat Surface

These CheetaHubs can be stacked anywhere there is a enough flat space, such as

on a table or desktop.
1. Stick the self-adhesive rubber foot pads

(that come with this package) on each

of the 4 concave spaces located on the

bottom of the first hub.

2. Place the first hub on a firm flat surface where you want to install the stack.

3. Repeat step 1 for each hub before stacking them.  The rubber foot pads cushion

the hub against shock/vibrations and provide space between each hub for

ventilation.

4. For added stability when stacking hubs, you can purchase the optional Stack Mount

Brackets from your Accton distributor, and secure each hub to the adjacent unit.

Connecting the Hub System

These hubs have 8 (or 16) RJ-45 dual-speed RJ-45 station ports, one of which also

serves as a dual-speed MDI daisy-chain port.  Two stack backplane ports are also

located on the rear panel; using these ports you can stack up to six hubs.

Making a Connection via an RJ-45 Station Port

You can connect any RJ-45 (MDI-X) station port on the hub to any device that uses

a standard network interface such as a workstation or server, or to a network inter-

connection device such as a bridge or router (depending on the port type implemented).
1. Prepare the network devices you wish to network.  Make sure you have installed

10BASE-T or 100BASE-TX network interface cards for connecting to the hub's

RJ-45 (MDI-X) station ports.

2. You also need to prepare straight-through shielded or unshielded twisted-pair

cables with RJ-45 plugs at both ends.  Use 100

 Category 3, 4 or 5 cable for

standard 10 Mbps Ethernet connections, or 100

 Category 5 cable for 100 Mbps

Fast Ethernet connections.

3. Connect one end of the cable to the RJ-45 port of the network interface card, and

the other end to any available (MDI-X) station port on the hub.  The RJ-45 ports

support 10 Mbps and 100 Mbps Ethernet connections.  When inserting an RJ-45

plug, be sure the tab on the plug clicks into position to ensure that it is properly

seated.  Using a hub in a stand-alone configuration, you can network up to 8 (16)

end nodes.

I

Do not plug a phone jack connector into any RJ-45 port.  This may damage the hub.

Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards.

Notes:

1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet).

2. We advise using Category 5 cable for all network connections to avoid any

confusion or inconvenience in the future when you upgrade attached devices

to Fast Ethernet.

Making a Connection to the BNC Port (EH3016N, EH3016N-SW only)

Plug the BNC T-type connector (provided with the hub) into a BNC port on the back

of the EN3016N or EN3016N-SW.  When connecting two devices via BNC ports,

there should be at least 0.5 meters (1.64 feet) of coaxial cable between the two BNC

ports.  A thin Ethernet coaxial cable segment can be extended up to 185 meters

(607 feet) and can link up to 30 nodes.  If the unit is at the terminal end of a

segment, connect a 50

 terminator to the open end of the "T" connector.

Making a Connection via an MDI Daisy-Chain Port

Use the RJ-45 MDI daisy-chain por to connect to another compatible hub or switch.
1. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45

plugs at both ends.  Use 100

 Category 3, 4 or 5 cable for standard 10 Mbps

Ethernet connections, or 100

Ω 

Category 5 cable for 100 Mbps Fast Ethernet

connections.

2. Connect the MDI port on the switch to any MDI-X station port on the other device.

When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to

ensure that it is properly seated.

Notes:

1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet).

2. To connect to another hub or switch, you can also connect from any MDI-X

port on the switch to an MDI daisy-chain port on the other device, or attach to

(MDI-X) station ports at both ends using crossover cable.

Содержание CheetaHub Power-3008N

Страница 1: ...CheetaHub Power 3008N 3016N Quick Installation Guide EH3008N SW EH3016N SW E1098 R01 150001 102...

Страница 2: ...to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes International Headquarters USA Headquarte...

Страница 3: ...ps and 100 Mbps Ethernet networks all for a price that s comparable to a standard Ethernet or Fast Ethernet hub Moreover the smart design built into the display panel provides a friendly interface tha...

Страница 4: ...type implemented 1 Prepare the network devices you wish to network Make sure you have installed 10BASE T or 100BASE TX network interface cards for connecting to the hub s RJ 45 MDI X station ports 2 Y...

Страница 5: ...ar panel Verifying Port Status Check each connection by viewing the port status indicators shown in the following figure and table D E L e t a t S n o i t a c i d n I r e w o P n e e r g n O r e w o p...

Страница 6: ...8x4 56x1 46 in 10 75x6 54x1 69 in Weight 0 83Kg 1 83lb 1 65Kg 3 64lb Temperature 0 40 C 32 104 F Standard Operating 25 70 C 13 158 F Storage Humidity 5 to 95 Non condensing Certification CE Mark Emiss...

Страница 7: ...e in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to...

Страница 8: ...u o r g e d a l b l e l l a r a P s t l o V 0 4 2 t e S d r o C d e i f i t r e C A S C d e t s i L L U a c i r e m A h t r o N d r o c r o t c u d n o c e e r h t T J S r o T V S e p y t G W A 8 1 m...

Страница 9: ...to replace consumable components such as fuses power transformers and mechanical cooling devices The warranty does not cover the product if it is damaged in the process of being installed Accton reco...

Отзывы: