Quick Installation Guide

CheetahSwitch Workgroup-2027

4

5

Restrictions on Cascade Length

 - Because the CheetahSwitch breaks up the

path for connected devices into separate collision domains, it  has no restrictions on

cascade length.  Therefore, when cascading devices other than this switch, do not

include it or any connected cabling in your calculations for cascade length.

Making a Connection via the AUI Port

The AUI port is used for connection to the following 10 Mbps media types:

• 

 Thin Ethernet (10BASE2)

• 

 Thick Ethernet (10BASE5)

• 

 Remote fiber optic link (10BASE-F)

Thin Ethernet

 - Attach a BNC transceiver to the AUI port and plug the BNC T-type

connector into a BNC port on the transceiver.  When connecting two devices via

BNC ports, there should be at least 0.5 meters (1.64 feet) of coaxial cable between

the two BNC ports.  A thin Ethernet coaxial cable segment can be extended up to

185 meters (607 feet) and can link up to 30 nodes.  If the unit is at the terminal end

of a trunk segment, connect a 50

terminator to the open end of the "T" connector.

Note:

 Thin Ethernet only supports half-duplex communications.

Thick Ethernet

 - Attach an AUI to 10BASE5 transceiver to the thick Ethernet trunk,

and then run an AUI drop cable (with 15-pin D-type connectors on both ends)

between the AUI port on the switch and the transceiver.  Note that the maximum

length of an AUI drop cable is 50 meters (164 feet).  A thick Ethernet segment can

be extended up to 500 meters (1640 feet) and can link up to 100 nodes.

Note

: Thick Ethernet only supports half-duplex communications.

Fiber Optic 

- If you plan to use the AUI port for connecting fiber optic cable, attach

a fiber optic transceiver (MAU) to the AUI port, and then connect the transceiver to

the remote device.  Note that 10 Mbps fiber can be extended up to two kilometers

(1.24 miles), regardless of whether you are running the link at half or full duplex.

Note

: Your fiber optic transceiver may or may not support full-duplex

communication, depending on the manufacturer.

Connecting to an Uplink Module

Additional network expansion can be achieved by inserting an optional

100BASE-TX or 100BASE-FX Uplink Module into either of the slots on the front

panel.  These Fast Ethernet modules act as a two-port switch (i.e., for external

connection and for interfacing with the internal switching hardware).
The 100BASE-TX module supports connection to

either 10 Mbps Ethernet or 100 Mbps Fast Ethernet

by automatically adjusting to the transmission speed

of the attached device.  It provides both RJ-45

MDI-X and MDI ports to simplify connection to end-

node devices with a standard Ethernet interface

(using the MDI-X port) or to another compatible

switch or hub (using an MDI to MDI-X connection).
Both SC and ST type modules are provided for

100BASE-FX. These modules run at 100 Mbps.

Using either of these fiber modules, you can run

a fiber optic link up to two kilometers (1.24 miles)

when using full duplex, or up to 412 meters (0.25

miles) with half duplex.

The 100BASE-TX Uplink Module can set the transmission mode to full or half

duplex via auto-negotiation.  However if the attached device does not support auto-

negotiation, you can manually configure the connected port to half or full duplex using

the configure button or console interface.  (See "Configuring the Switch" on page 7.)

I

 

The uplink modules are not hot-swappable.  Be sure you power off the switch

before installing any of these modules.

Installing an Uplink Module

 - You can install an uplink module as described below:

1. Disconnect power to the switch.

2. Remove the face plate on the expansion slot (or a previously installed uplink

module) by removing the two screws with a cross-head (Phillips) screwdriver.

3. Before opening the package that contains the uplink module, touch the bag to

the switch casing to discharge any potential static electricity.

4. Remove the module from the anti-static shielded bag.

5. Holding the module level, gently push it all the way into the expansion slot,

ensuring that it firmly engages with the connector.

6. If you are sure the module is properly mated with the connector, replace the

retainer screws to secure the module in the expansion slot.

7. Run corresponding media type between the uplink module and the target device.

Connecting Twisted-pair Cabling

 - If you will be using the 100BASE-TX module,

prepare Category 5 straight-through twisted-pair cable with RJ-45 plugs at both

ends.  When connecting the module directly to an end-node device (e.g., a

workstation or file server), a bridge or router, run cable from the MDI-X port on the

uplink module to the target device.  However, when connecting the module to a

compatible switch or hub, connect one end of the cable to the MDI port on the

uplink module, and the other end to an MDI-X port on the target device (or vice

versa).  When inserting an RJ-45 plug, be sure the tab on the plug clicks into

position to ensure that it is properly seated.  Note that as a general rule, the length

of any twisted-pair cable should not exceed 100 meters (328 feet).

Connecting Fiber Optic Cabling

 - If you are using a 100BASE-FX module,

prepare fiber optic cable with SC or ST connectors at both ends.  When connecting

the module directly to an end-node device (e.g., a workstation or file server), run

cable from the Rx (Tx) port on the module to the Tx (Rx) port on the target device.

When inserting the cable, be sure the tab on the plug clicks into position to ensure

that it is properly seated.  Note that as a general rule, the length of fiber optic cable

should not exceed 2 kilometers (1.24 miles) when the link is operated at full duplex

or 412 meters (0.25 miles) for half duplex.

Powering on the Switch

1. Plug the power cord into the power socket at the rear of the switch, and the

other end into a power outlet.

2. Check the LED marked Power on the front panel to see if it is on.  The unit will

automatically select the setting that matches the connected input voltage.

Therefore, no additional adjustments are necessary when connecting it to any

input voltage within the range marked on the rear panel.

3. The switch performs a self-diagnostic test upon power-on.  (Note that this test

takes about 15 seconds to complete.)

Note

: The unit supports a "hot remove" feature which permits you to connect/

disconnect cables without powering off the switch and without disrupting the

operation of the devices attached to the switch.

Содержание CheetahSwitch Workgroup-2027

Страница 1: ...CheetahSwitch Workgroup 2027 Quick Installation Guide ES2027 E0298 R03 150185 101...

Страница 2: ...this document is subject to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes International He...

Страница 3: ...or attached PCs all with conventional cabling and adapters It completely eliminates the bottlenecks of shared 10Mbps Ethernet networks by providing a wide bandwidth of up to 460 Mbps This makes it id...

Страница 4: ...hing mode for any of the switch s ports to cut through or store and forward using the console interface See Using the Console Program on page 7 Making a Connection via an MDI X Station Port You can co...

Страница 5: ...on However if the attached device does not support auto negotiation you can manually configure the connected port to half or full duplex using the configure button or console interface See Configuring...

Страница 6: ...o t t r o p I U A m o r f e l b a c p o r d f o h t g n e l m u m i x a M 2 t e e f 4 6 1 s r e t e m 0 5 t e e f 4 6 1 s r e t e m 5 0 Configuring the Switch The transmission mode for all ports must...

Страница 7: ...nsist of up to 14 alphanumeric characters and are case sensitive Restarting the System Use the Restart command to reboot the system Factory Reset Use this command to restore factory defaults and reboo...

Страница 8: ...em link Troubleshooting Diagnosing Switch Indicators The switch can be easily monitored through panel indicators to assist the network manager in identifying problems This section describes common pro...

Страница 9: ...r RJ 45 connections Category 3 or greater for 10 Mbps connections and Category 5 for 100 Mbps connections Class A Canada Department of Communications This digital apparatus does not exceed the Class A...

Страница 10: ...icherheit nur von authorisiertem Servicepersonal ge ffnet werden 14 Wenn folgende Situationen auftreten ist das Ger t vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu berpr fen a...

Отзывы: