Accton Technology AS9817-64O Скачать руководство пользователя страница 2

Quick Start Guide

–  2  –

Mount the Device

Ground the Device

Connect Power

1.

 -48 – -60 VDC

2.

 DC return

3.

 

4.

 Signal -

Warning:

 

For a safe and reliable installation, use only 

the accessories and screws provided with the device. Use 

of other accessories and screws could result in damage to 

the unit. Any damages incurred by using unapproved 

accessories are not covered by the warranty.

Avertissement:

 

Pour une installation sûre et fiable, 

utilisez uniquement les accessoires et les vis fournies avec 

l’appareil. L’utilisation d’autres accessoires et vis pourrait 

endommager l’appareil. Les dommages causés par 

l’utilisation d’accessoires non approuvés ne sont pas 

couverts par la garantie.

Caution: 

The device must be installed in a restricted-access 

location.

Attention: 

L’appareil doit être installé dans un emplacement 

à accès restreint.

Note:

 The device has the Open Network Install Environment 

(ONIE) software installer preloaded, but no device software 

image. 

Note:

 The drawings in this document are for illustration only 

and may not match your particular model.

Caution: 

This device must be installed in a 

telecommunications room or a server room where only 

qualified personnel have access.

Attention: 

Cet appareil doit être installé dans une salle de 

télécommunications ou une salle de serveurs où seul le 

personnel qualifié a accès.

Note:

 Stability hazard. The rack may tip over causing serious 

personal injury.

Before extending the rack to the installation position, read the 

installation instructions.

Do not put any load on the slide-rail mounted equipment in the 

installation position.

Do not leave the slide-rail mounted equipment in the installation 

position.

1

Using the Slide-Rail Kit

Follow instructions in the install guide provided in the slide-rail kit to 
mount the device in a rack.

Note:

 When using only one AC PSU to power a fully loaded 

system, be sure to use a high-voltage source (200–240 VAC).

2

Verify Rack Ground

Ensure the rack on which the device is to be mounted is properly 
grounded and in compliance with ETSI ETS 300 253. Verify that there is 
a good electrical connection to the grounding point on the rack (no 
paint or isolating surface treatment).

Attach Grounding Wire

Attach a grounding wire to the grounding point on the device rear 
panel using two M6 screws and washers with a grounding lug (Panduit 
LCDXN2-14AF-E or equivalent, not included). The grounding lug 
should accommodate #2 AWG stranded copper wire (green with 
yellow stripe, not included).

3

Install one or two AC or DC PSUs and connect them to an AC or DC 
power source.

4

1

1

2

2

3

Installation