A111 Pulsed Coherent Radar (PCR)
Datasheet, v1.8
Page 19 of 34
2019-06-12
© 2019 Copyright by Acconeer
7.3 Power Up Sequence
The power-up sequence is described using the recommended integration shown in the below figure:
A111
INTERRUPT
SPI_SS
SPI_MISO
SPI_MOSI
SPI_CLK
ENABLE
VIO_1a,b
VIO_2a,b
VIO_3a,b
VBIAS
XIN
XOUT
G
N
D
s
R1
1.8V
X1
C8
C7
R2
C4
C1
C5
C2
C6
C3
Host
Figure 7.3. Recommended integration of the A111 radar sensor.
The power up sequence is shown in below figure.
Time
VIO_1-3a,b
ENABLE
t
1
t
2
XIN
Figure 7.4. Power up sequence