6
www.acclaimlighting.com
OUTPUT CONNECTIONS
The Aqua Drivers have multiple constant current output ports,
each of which uses an 8-pin terminal block. Each output port
provides multiple channels, the addressing of which are
decided by the front panel switch settings (see
“Aqua Driver mode control” on page 14).
PORT CONNECTION CABLES
Each Aqua Graze fixture is supplied with a 100’ (30m) cable terminated in an 8-pin terminal
connector. In situations where this supplied cable is shortened and then wired into a
separate supply cable, ensure the conductors of the supply cable are of sufficient size and
that the total cable length (including that which remains of the Aqua Graze cable) is not
exceeded:
Conductor size
Maximum length (including Aqua Graze cable)
•
18 AWG (0.823mm
2
)
Up to 100’ (30m)
•
14 AWG (2.081mm
2
)
Up to 125’ (38m)
•
12 AWG (3.309mm
2
)
Up to 150’ (45m)
4’
1’
700mA
350mA
IMPORTANT: 1’ fixtures require a different drive
current setting to the longer 4’ fixtures - it is vitally
important to select the correct setting to avoid
damage to the fixtures. The drive current setting
affects all outputs equally, so it is not possible to mix
the two sizes on the same driver unit.
Содержание AQUA DRIVER 400
Страница 1: ...User guide Aqua Graze...
Страница 2: ......
Страница 22: ...20 www acclaimlighting com DIMENSIONS AQUA DRIVER 400 Weight 4 4 lbs 1 99 kg...
Страница 24: ...www acclaimlighting com...