AccessZone ® - GC500/GC600 Series – Installation Manual
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies
2011-03-21 US 1.05
Copyright © 2005-2011 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www.mvc-data.com E-mail [email protected] Phone +45 25 12 84 02
5/7
2
System Overview
This section presents a system overview:
3
Specification
Description:
Dimensions
127 x 47 x 8 mm (H x W x D)
Weight
100g
IP
67
Operation temp.
-30°C - +80°C
Humidity
100%
Electrical:
Supply
12V DC, max. 120mA
1)
Power
max. 1,5W
Outputs
2 outputs (open collector type), 500mA
2)
Inputs
2 inputs
1)
A 500mA low noise power supply of high quality should be used
2)
The active levels (high/low) of inputs and outputs can be configured. Please refer to the User
Manual for more information.
Input 1 (IN1)
Block Operation
(Prevents any door/
gate activation)
Output 2 (OC2)
(Pulse/Level/Latched)
Door lock/gate control
Output 1 (OC1)
(Level/Latched)
Alarm Arm and Disarm/
Light Control Switch
Input 2 (IN2)
REX Button and
Alarm arm/
Alarm reject
arming