System Command Description: 

 

Only in configuration mode: 

 

Change Master PIN Code 

Change the 8-digit master PIN Code 
E.g. to change Master PIN to 12345678 enter: 
"

12345678

 

 

Add new User – Easy Enrolment

 

By default no users have to be added. The 
reader forwards all Bluetooth ID on the 
Wiegand bus. Add users if a personal PIN code 
is required. 

Command must be executed on the users 
mobile phone. It adds the used mobile phone to 
the specified storage position. 
E.g. add user with PIN code 1234 on position 3 
enter:  "

03,1234

 

 

Change System Configuration 1

 

This command handles Wiegand facility code, 
Wiegand type. 10 different formats are 
supported. Default is Wiegand 26.  
See User Manual for details 
 

 

Change System Configuration 2 

This command handles system detection range 
and I/O configuration. See User Manual for 
details.  

 

System Command Description: 

 

By administrators or in configuration mode: 

 

Add new User

 

By default no users have to be added. The 
reader forwards all Bluetooth ID on the 
Wiegand bus. Add users if a personal PIN code 
is required.

 

Adds a new user on the specified storage 
position. The users Bluetooth address must be 
entered. Deletion of current user is not required 
E.g. add user with ID 0022b4b62918 and PIN 
code 1234 on position 1 enter:  
"

01,0022b4b62918,1234

"  

 

 

Delete User

 

Deletes the user on the specified storage 
position. 
E.g. delete administrator stored on position 1 
enter: "

01

 

 

Execute System Commands 

See description below 

 

 

Execute System Configurations 

See description below 

 

 

Execute System Commands: 

Some predefined system commands.  

 

 

E01

” -  Performs a System Reset

 

 

E02

” -  Performs a Factory Reset

 

 

E03

” -  Enter Configuration Mode

 

 

E04

” -  Performs a Factory Reset and enters 

Configuration Mode (“E02” + “E03”)

 

 

E05

” -  Erases the complete user list and adds 

the default Any user “FFFFFFFFFFFF” on 
storage position 01 as new administrator

 

 

E06

” -  Increases the RX range to allow access to 

the users further away (+3 dBm steps)

 

 

E07

” -  Decreases the RX range to allow the 

users to be closer to the reader before 
access (-3 dBm steps)

 

 

Execute System Configurations: 

Some predefined system configurations which 
helps adjusting the system to the required 
detection distance. 

 

 

C01

” - Very short range ≈ 10 cm 

 

C02

” - Door access - short ≈ < 50 cm 

 

C03

” - Door access - normal ≈ < 2 m 

 

C04

” - Gate access ≈ < 5 m  

 

C05

” - Gate access - long ≈ < 10 m 

 

C06

” - Very long range ≈ < 100 m 

  

The specified distance is indicative only and will 
depend on actual installation.

 

Smart Phone Apps:

 

An AccessZone Administrator app helps building 
up the system commands. App is available for 
iOS and Android. 
 
Please see our web page for further details: 
http://www.mvc-data.com/Smart_Phones.html 

 

 

 