2015.04.16
Flow2 - Stairlift
Tab 06: Systematic fault finding
www.ThyssenKruppAccessibility.com
4.3
Warning messages
These codes are used to draw the technician’s attention to certain conditions.
When these warnings are generated they don’t stop the lift and the user will not be aware of these.
However, they are shown in the display on the service board and can be seen in the error log in mode
-9- (except C04).
Warning code
C04
Warning message
Tilt > 2
⁰
Description
Chair is more than 2
⁰
out of level
Safety action
Reduce speed
Possible solution
Program correct speed in rail data
Warning suppressed in
Mode -3- / ELD mode
Warning code
C56
Warning message
Unexpected negative charging contact
Description
An unexpected reset contact was detected
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode
Warning code
C58
Warning message
Negative charging contact expected
Description
A reset contact was expected but not detected.
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode
Warning code
C60
Warning message
Position outside max. rail length
Description
The maximum raillength is 45 m.
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode
Warning code
C61
Warning message
Unexpected reset point swivel
Description
The zero opto has been detected at an unexpected position
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode
Warning code
C62
Warning message
Inverted zero opto signal swivel
Description
Signal goes from high to low instead of from low to high or vice versa.
Safety action
Report the warning
Possible solution
Warning suppressed in
Mode -3- / ELD mode