CONNECTING THE AUTO DRAIN
TM
HIGH-SPEED AUTO DRAIN
TM
FOR AIR SYSTEM
• Drain System requires the connection to a minimum 1 ½ sanitary drain line.
• Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’ pipe.
• Do not change or modify the location and or piping of the Back Flow Preventer.
• The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.
• Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.
• Glue the High-Speed Auto Drain
TM
Fittings, pipe and drain overflow assembly to the sanitary drainage pipe.
NOTE: WATER TIGHT INSTALLATION OF THE WASTE/ OVERFLOW IS THE INSTALLER’S RESPONSIBILITY. DRAIN LEAKAGE IS
EXCLUDED FROM THE ACCESS TUBS WARRANTY OF THIS PRODUCT.
NOTE: WE HAVE TAKEN RESPONSIBLE PRECAUTIONS TO ENSURE THE HIGH-SPEED AUTO DRAIN
TM
IS SUITABLE FOR
RESIDENTIAL PLUMBING. IT IS RESPONSIBILITY OF THE INSTALLER TO INSURE THE SANITARY SYSTEM IS ACCEPTABLE
FOR THE USE OF THE HIGH-SPEED AUTO DRAIN
TM
. WE DO NOT ACCEPT RESPONSIBILITY FOR DAMAGE ARISING FROM THE
USE OF THE HIGH- SPEED AUTO DRAIN
TM
.*
*-Ensure compliance with local plumbing codes.
Connection of the Auto Drain for air units
• Drain System requires the connection to a minimum 1 ½ sanitary drain line.
• Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’’ pipe.
• Do not change or modify the location and or piping of the Back Flow Preventer.
• The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.
• Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.
• Glue the Auto Drain, pipe and drain overflow assembly to the sanitary drainage pipe.
• NOTE: Water tight installation of the waste/ overflow is the installer’s responsibility. Drain leakage is excluded from Access Tubs warranty of
this product.
Pumps & Amperage
*One dedicated electrical circuit
required for bathtub installation
• Air Models: 20 Amp Circuit
We have taken responsible precautions to ensure the Auto Drain is suitable for residential plumbing. It is
the responsibility of the installer to insure the sanitary system is acceptable for the use of the Auto Drain.
We do not accept responsibility for damage arising from the use of the Auto Drain.
*
*-ensure compliance with local plumbing codes and requirements
.
ACCESS TUBS AUTO DRAIN SPECIFICATIONS
110V/60hz pump (20 Amp Circuit)
overflow
drain cable
drain cable
drain
drain shoe
sanitary tee
drain tee
90° Elbow
reducer 1 1/2-1”
back flow preventer
*
One
dedicated
electrical
circuit
required
for bathtub installation
button (on/off)
AIR AUTO DRAIN
TM
CONNECTION
OPERATING INSTRUCTIONS