background image

Access Tubs 

5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-249-2388 FAX: 866-560-1060 www.accesstub.com

Page 11

Access Tubs

CONNECTING THE AUTO DRAIN

TM

HIGH-SPEED AUTO DRAIN

TM

 FOR HYDRO TUB

•  Drain System requires the connection to a minimum 1 ½ sanitary drain line.

•  Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’ pipe.

•  Do not change or modify the location and or piping of the Back Flow Preventer.

•  The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.

•  Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.

•  Glue the High-Speed Auto drain

TM

 Fittings, pipe and drain overflow assembly to the sanitary drainage pipe.

NOTE: WATER TIGHT INSTALLATION OF THE WASTE/ OVERFLOW IS THE INSTALLER’S RESPONSIBILITY. DRAIN LEAKAGE IS 

EXCLUDED FROM THE ACCESS TUBS WARRANTY OF THIS PRODUCT.

NOTE: WE HAVE TAKEN RESPONSIBLE PRECAUTIONS TO ENSURE THE HIGH-SPEED AUTO DRAIN

TM

 IS SUITABLE FOR 

RESIDENTIAL PLUMBING. IT IS RESPONSIBILITY OF THE INSTALLER TO INSURE THE SANITARY SYSTEM IS ACCEPTABLE 

FOR THE USE OF THE HIGH-SPEED AUTO DRAIN

TM

. WE DO NOT ACCEPT RESPONSIBILITY FOR DAMAGE ARISING FROM THE 

USE OF THE HIGH- SPEED AUTO DRAIN

TM

.*

*-Ensure compliance with local plumbing codes.

Connection of the Auto Drain for hydro units

• Drain System requires the connection to a minimum 1 ½ sanitary drain line.
• Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’’ pipe.
• Do not change or modify the location and or piping of the Back Flow Preventer.
• The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.
• Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.
• Glue the Auto Drain, pipe and drain overflow assembly to the sanitary drainage pipe.
• NOTE: Water tight installation of the waste/ overflow is the installer’s responsibility. Drain leakage is excluded from Access Tubs warranty of 
this product.

We have taken responsible precautions to ensure the Auto Drain is suitable for residential plumbing. It is 

the responsibility of the installer to insure the sanitary system is acceptable for the use of the Auto Drain. 

We do not accept responsibility for damage arising from the use of the Auto Drain.

*

*-ensure compliance with local plumbing codes and requirements

ACCESS TUBS AUTO DRAIN SPECIFICATIONS

button (on/off)

diverter valve

jets

overflow

drain cable

drain cable

drain 

drain shoe 

sanitary tee

drain tee

90° Elbow

reducer 1 1/2-1”

back flow preventer

110V-60hz pump (15 Amp Circuit)

Pumps & Amperage

*Two dedicated electrical circuits required 
for bathtub installation 

• Hydro Models: 15 Amp Circuit 
(Hydro) & 15 Amp Circuit (Heater)

*

Two

 

dedicated

 

electrical

 

circuits

 

required

 

for bathtub installation

 

HYDRO AUTO DRAIN

TM

 CONNECTION

OPERATING INSTRUCTIONS

Содержание 3060SI HYDRO

Страница 1: ...Page 25 AccessTubs INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS ACCESS TUBS 5701 NW 35 Avenue Miami FL 33142 Phone 877 249 2388 Fax 866 560 1060 info accesstub com http www...

Страница 2: ...wyoutoenjoythepleasuresofindependentbathing ataverycomfortableprice TheWalk inHydrobathisdesignedtofitconvenientlyintoyourshowerstallorpreviousbathtubarea Ourtubsaredesignedaround yourconvenienceandco...

Страница 3: ...SMANUAL 4 UNPACKINGTHEUNIT 5 PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ELECTRICALPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECTION 10 CONNECTINGTHE AUTODRAINTM 11 INSTALLATIONAND EXTENSIONPANE...

Страница 4: ...on the market today Until recently if you have difficulty getting in and out of a bathtub it was almost impossible for you to take a bath Access Tubs specializes in accessibility and security Safe tr...

Страница 5: ...sure that your warranty is registered and confirmed with the manufacturer please take a few moments to complete sign and returntheProduct RegistrationCard below within30days WARRANTYCONFIRMATION By re...

Страница 6: ...ECTORDAMAGE INTHEEVENTOFAPROBLEM THEUNITMUSTNOTBEINSTALLED IFTHECRATEORTHEPRODUCT HAS BEEN DAMAGEDDURINGSHIPPING PLEASECALLUSIMMEDIATELY THISPRODUCTMUSTBEINSTALLED BY A LICENSED CERTIFIED CONTRACTOR L...

Страница 7: ...ngtheplumbingandcausingaleak INSPECTINGTHEUNIT Immediately inspect the unit for damage even if there is no carton damage Once the unit is installed surface damages will be assumed to beinstallationrel...

Страница 8: ...thetubuntilitisabovethehighestjet Ifit sasoakerfilluptonormalwaterheightlevel Allowthewater tostandintubfor30minutesandtheninspectallplumbingandsealsforleaks Iftubisjetted supplyelectrictounitandrunfo...

Страница 9: ...vel Ifthefloorisnotlevel adjustall6levelingfeettoperfectlylevelthetub NOTE IT IS IMPORTANT THAT ALL LEVELING FEET ARE COMPLETELY TOUCHING THE FLOOR ANDLEVELFORTHEDOORSYSTEMTOWORKPROPERLY 2 Checkto ens...

Страница 10: ...ebathtub andfactoryinstalledcomponents Branch circuits must be rated for 110 120 volts Use 12 Gauge 3 conductor cable for the circuits If the length run exceeds 100 feetcheckwithlocalcodesforrequireme...

Страница 11: ...UMP MOTOR ALLTUBSCOMEWITHANACCESSPANEL FORTHE PUMP MOTOR GENERALGUIDE THROUGH Standardinstallation Afterframingisacomplete seeattacheddiagrams setproductinplacetomakecertainthatthetubcan be properly l...

Страница 12: ...Access Tubs 5701 NW 35 Avenue Miami FL 33142 PHONE 877 249 2388 FAX 866 560 1060 www accesstub com Page 10 AccessTubs OPERATING INSTRUCTIONS...

Страница 13: ...anitary drain line Use UPC Approved PVC Glue primer and Schedule 40 1 pipe Do not change or modify the location and or piping of the Back Flow Preventer The sanitary tee is installed directly above th...

Страница 14: ...2 AccessTubs Wall Bathroom Waterproof Sheetrock Mortar Tile Silicone 6 x1 2 Screw Custom built wall section s for open ends or install against corners of full wall No included with tub Contact your in...

Страница 15: ...NE 877 249 2388 FAX 866 560 1060 www accesstub com Page 13 AccessTubs FAUCET INSTALLATION The 30x60 Step In models is not equipped with a faucet deck Third party wall or floor mounted faucet sets must...

Страница 16: ...se in body temperature This can be a serious medical condition and all bath users are cautioned against lengthy immersion at high water temperatures Should you become light headed dizzy or nauseous im...

Страница 17: ...the GFCI fails to operate in this manner there may be a ground current flowing indicating the possibility of an electric shock Do not use this massage bathtub Disconnect the jet massage bathtub and ha...

Страница 18: ...nd exiting the tub It is recommended to leave the door in the open position when the tub is not inuse Thepumpisoperatedbythehydrocontrolbutton whichstartsthewaterflow see page18 Adjustthedirectionandr...

Страница 19: ...accesstub com Page 17 AccessTubs IN LINEHEATERS Ifyourbathtub isequippedwithanin lineheater itwilloperateonlywhenthepumpison NOTE THEIN LINEHEATERISDESIGNEDTOKEEPYOURWATERWARMERLONGER BUTISNOTDESIGNE...

Страница 20: ...60 www accesstub com Page 18 AccessTubs TUB CONTROLS HYDROCONTROL PUMP Used to turn thewaterjetsON andOFF AIRPRESSURECONTROL Usedtoincreaseordecreaseairpressureflowingthrough thewater jets AUTODRAINTM...

Страница 21: ...asdishwashingmachinedetergent Turn on whirlpoolsystemandrunfor10minutes Drain tub completely Filltub with coldwaterabovejets Turn on whirlpoolsystemandrunfor15minutes Drain tub completely Cleaningthes...

Страница 22: ...any property for any reason including but not limited to manufacturer defects or improper installation Manufacturer will assume no responsibility for the loss of the system inconvenience due to loss...

Страница 23: ...roper maintenance The replacement door seal will be issued to the end user and it will be the responsibility of the end user to determine the means of installation Manufacturer will not be liable for...

Страница 24: ...ionedinthewarranty thefollowingproceduresapply Requestsfor returnsand orexchangesmustbemadewithin30daysofreceiptofproduct Theproductmustbeinitsoriginal packaging and receivedatAccessTubs insaleablecon...

Страница 25: ...n Card Name Address City State Zip Phone Date of Purchase Dealer Address Installed by Address State Phone State Zip I have read the Access Tubs Owner s Manual carefully and understand and agree that a...

Страница 26: ...ccess Tubs 5701 NW 35 Avenue Miami FL 33142 PHONE 877 249 2388 FAX 866 560 1060 www accesstub com AccessTubs INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS America sWalk InTub...