FEB100-NT
Product Manual
FEB100-NT, Rev A
Page 1
FEB100-NT O
VERVIEW
:
The FEB100-NT Free Exit Box uses a “No Touch”
Infrared sensor to sense a user and open the door or
gate. The built-in time delay makes it ideal for
pedestrian gates using magnetic locks or electric
strikes. A built-in manual override button can be used
if bad weather prevents the infrared sensor from
working.
•
“No Touch” Infrared Sensor for handsfree
operation.
•
Manual override for bad weather situations.
•
Built-in time delay for pedestrian gates.
•
Built-in terminal strip for simple and clean
wiring.
•
Built-in LED housing for night time use.
M
OUNTING
T
HE
S
YSTEM
:
The system can be mounted on a standard pedestal
or directly to a wall or flat surface. A 3/4” knockout is
located on the back of the box for conduit
connections. Rear mounting holes are available for
mounting screws and anchors. Follow all safety
warnings and precautions when mounting the system.
IMPORTANT: Remove the hinged faceplate and
electronics before removing the knockout to
prevent damage.
Pedestal Mounting
:
1. Use security screws and lock nuts to securely attach the
back box to a gooseneck post.
2. If the mounting holes are not used, fill the holes with a
plug or sealant to prevent water from entering the box.
Wall Mounting:
1. Mount the system to a wall or flat surface. Use
appropriate mounting screws or anchors to securely
attach the system.
2. Never mount the system to a moving gate, gate panel,
or next to a gate that causes vibration to the mounting
point. Continuous vibration from moving or slamming
gates can cause damage to the unit and is not covered
under warranty.
C
ONNECTING
P
OWER
:
The FEB100-NT can only be powered by 12-24 VDC.
Use the 12VDC transformer supplied with the unit. To
power the unit:
1.
Connect 12VDC to the 12+ and 12- terminals.
(Must be 12-24 VDC only - confirm polarity)
•
12VDC+ (red wire) to 12+ terminal.
•
12VDC- (black wire) to 12- terminal.
C
ONNECTING
A G
ATE
O
PERATOR
:
To connect the FEB100-NT to a gate operator:
1. Connect two wires from the gate operator Exit/
Open Input and gate operator Common Input:
•
Gate operator Exit/Open to NO terminal.
•
Gate operator Common to NOC terminal.
Mount the system at least 10 feet away from a
vehicular gate and its travel.
!
!
DO NOT mount operating devices accessible
through the gate or in between gate and wall.