background image

iv

Warranty

Prior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications.  However,
should  equipment  failure  occur, ACCES  assures its customers that prompt service and support will be
available.  All equipment originally manufactured by ACCES  which is found to be defective will be repaired
or replaced subject to the following considerations.

Terms and  Conditions

If a unit is suspected of failure, contact ACCES' Customer Service department.  Be prepared to give the unit
model number, serial number, and a description of the failure symptom(s).  We may suggest some simple tests
to confirm the failure.  We will assign a Return Material Authorization (RMA) number which must appear on
the outer label of the return package.  All units/components should be properly packed for handling and
returned  with  freight  prepaid  to  the  ACCES  designated Service Center, and will be returned to the
customer's/user's site freight prepaid and invoiced.

Coverage

First Three Years:  Returned unit/part will be repaired and/or replaced at ACCES option with no charge for
labor or parts not excluded by warranty.  Warranty commences with equipment shipment.

Following Years:  Throughout your equipment's lifetime, ACCES stands ready to provide on-site or in-plant
service at reasonable rates similar to those of other manufacturers in the industry.

Equipment Not Manufactured by ACCES

Equipment provided but not manufactured by ACCES  is warranted and will be repaired  according to the
terms and conditions of the respective equipment manufacturer's warranty.

General

Under  this  Warranty, liability of ACCES is limited to replacing, repairing or issuing credit (at ACCES
discretion) for any products which are proved to be defective during the warranty  period.   In no case is
ACCES  liable for consequential or special damage arriving from use or misuse of our product.  The  customer
is  responsible for all charges caused by modifications or additions to ACCES  equipment not approved in
writing by ACCES or, if in ACCES  opinion the equipment has been subjected to abnormal use.   "Abnormal
use" for purposes of this warranty is defined as any  use to which the equipment is exposed other than that use
specified  or  intended as evidenced by purchase or sales representation.  Other than the above, no other
warranty, expressed or implied, shall apply to any and all such equipment furnished or sold by ACCES.

Содержание ICOM-2S

Страница 1: ...ACCES I O PRODUCTS INC 10623 Roselle Street San Diego CA 92121 TEL 858 550 9559 FAX 858 550 7322 MODEL ICOM 2S USER MANUAL FILE MICOM 2S Eb...

Страница 2: ......

Страница 3: ...document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of ACCES nor the rights of others IBM PC PC XT an...

Страница 4: ...luded by warranty Warranty commences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonable rates similar...

Страница 5: ...2 1 3 5 Inch Diskette Installation 2 1 Directories Created on the Hard Disk 2 2 Installing the Card 2 4 Chapter 3 Option Selection 3 1 Communication Modes and Cabling Options 3 2 Interrupts 3 2 Chapte...

Страница 6: ...twork A 3 List of Tables Table 4 1 Standard Address Assignments for 286 386 486 Computers 4 1 Table 4 2 ICOM 2S Address Switch Setup 4 2 Table 4 3 Example Address Setup 4 2 Table 4 4 Standard COM Port...

Страница 7: ...e front of this manual The output transceiver used type 75176B is capable of driving extremely long communication lines at high baud rates It can drive up to 60mA on balanced lines and receive inputs...

Страница 8: ...Led Monitors Two LED indicators are provided on the ICOM 2S card The LEDs blink to indicate activity on the transmitting and receiving lines and are useful for problem diagnosis The blinking is more v...

Страница 9: ...t Compatible with RS422 and RS485 specifications Up to 32 drivers and receivers allowed on line Input Isolation 500 Volts from computer and between ports Receiver Input Sensitivity 200 mV differential...

Страница 10: ...ICOM 2S Manual 1 4 Manual MICOM 2S Eb Figure 1 1 ICOM 2S Block Diagram Only one serial channel shown...

Страница 11: ...een prompts to install the software for this card WIN95 98 NT 1 Place the CD into your CD ROM drive 2 The CD should automatically run the install program after 30 seconds If the install program does n...

Страница 12: ...contains C samples Win32 language Subdirectories containing samples for Win95 98 and NT WinRisc exe A Windows dumb terminal type communication program designed for RS422 485 operation Used primarily...

Страница 13: ...rams in DOS PCIFind exe A utility for DOS and Windows to determine what base addresses and IRQs are allocated to installed PCI cards This program runs two versions depending on the operating system Wi...

Страница 14: ...esigned for RS422 485 operation Used primarily with Remote Data Acquisition Pods and our RS422 485 serial communication product line Can be used to say hello to an installed modem RISCTerm stands for...

Страница 15: ...mounting bracket is properly screwed into place and that there is a positive chassis ground 9 Turn the computer ON and observe the LED indicators The LEDs will blink when there is any activity on the...

Страница 16: ...ng resistor should be divided and its center point grounded to help reduce noise voltage pickup To accomplish this also install a jumper at the position marked LD GND for 68 ohm termination resistance...

Страница 17: ...on the wire connections used to connect the two serial ports Tx is the transmit wires and Rx is the receive wires Communication Modes and Cabling Options Cable Mode Jumpers Card A Card B Simplex 2 wir...

Страница 18: ...X Full Half Duplex SX DX Simplex Duplex RTS Software RTS option AUTOA AUTOB Auto RTS option BIAS RS485 Bias Voltage CTS Forced CTS signal LD LDGND Transmission Load Jumpers See the Option Selection ch...

Страница 19: ...01F DMA Controller 1 020 03F INT Controller 1 Master 040 05F Timer 060 06F 8042 Keyboard 070 07F Real Time Clock NMI Mask 080 09F DMA Page Register 0A0 0BF INT Controller 2 0C0 0DF DMA Controller 2 0...

Страница 20: ...itches that are turned OFF and a binary 0 to switches in the ON position For example as illustrated in the following table switch selection corresponds to binary 10 1101 1xxx hex 2D8 The xxx represent...

Страница 21: ...tch Settings A9 A8 A7 A6 A5 A4 A3 COM1 IRQ 4 3F8 1 1 1 1 1 1 1 COM2 IRQ 3 2F8 1 0 1 1 1 1 1 COM3 IRQ 4 3E8 1 1 1 1 1 0 1 COM4 IRQ 3 2E8 1 0 1 1 1 0 1 Table 4 4 Standard COM Port Addresses Notice that...

Страница 22: ...ICOM 2S Manual 4 4 Manual MICOM 2S Eb...

Страница 23: ...et and change a port s settings ReadFile and WriteFile for accessing a port See the documentation for your chosen language for details Under DOS the process is very different The remainder of this cha...

Страница 24: ...to 9600 baud is outportb BASEADDR 0x0C outportb BASEADDR 1 0 The second initializing step is to set the Line Control Register at Base Address 3 This register defines word length stop bits parity and t...

Страница 25: ...e read from the chip Polling is not effective at high data rates above because the program cannot do anything else when it is polling or data could be missed The following code fragment implements a p...

Страница 26: ...e is done the card is ready to send data To transmit a string of data the transmitter must first check Bit 5 of the Line Status Register at Base Address 5 That bit is the transmitter holding register...

Страница 27: ...Output 3 Tx Transmit Data Complementary 4 Not Used 5 Gnd Isolated Common Ground Ground 6 5V Isolated 5V Supply 7 RTS Request to Send Output 8 CTS Clear to Send Input 9 Rx Receive Data Input TRx Table...

Страница 28: ...This is also true for RS422 but RS485 offers all the benefits of RS422 plus allows up to 32 devices to share the same twisted pairs An exception to the foregoing is that multiple RS422 devices can sha...

Страница 29: ...put Voltage loaded LD and LDGND 2V jumpers in 2V Driver Output Resistance 50 Driver Output Short Circuit Current 150 mA Driver Output Rise Time 10 unit interval Receiver Sensitivity 200 mV Receiver Co...

Страница 30: ...p Network The following illustration shows a typical multidrop or party line network Note that the transmission line is terminated on both ends of the line but not at drop points in the middle of the...

Страница 31: ...ICOM 2S Manual A 4 Manual MICOM 2S Eb...

Страница 32: ...ccesioproducts com Customer Comments If you experience any problems with this manual or just want to give us some feedback please email us at manuals accesioproducts com Please detail any errors you f...

Отзывы: