background image

Manual PCIe-DIO-24HS PCI Express Digital I/O Card 

Warranty

 

 
Prior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications. However, 
should equipment failure occur, ACCES assures its customers that prompt service and support will be available. 
All equipment originally manufactured by ACCES which is found to be defective will be repaired or replaced 
subject to the following considerations. 
 

Terms and Conditions

 

 
If a unit is suspected of failure, contact ACCES' Customer Service department. Be prepared to give the unit 
model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests 
to confirm the failure. We will assign a Return Material Authorization (RMA) number which must appear on the 
outer label of the return package. All units/components should be properly packed for handling and returned 
with freight prepaid to the ACCES designated Service Center, and will be returned to the customer's/user's site 
freight prepaid and invoiced. 
 

Coverage

 

 
First Three Years: Returned unit/part will be repaired and/or replaced at ACCES option with no charge for labor 
or parts not excluded by warranty. Warranty commences with equipment shipment. 
 
Following Years: Throughout your equipment's lifetime, ACCES stands ready to provide on-site or in-plant 
service at reasonable rates similar to those of other manufacturers in the industry. 
 

Equipment Not Manufactured by ACCES

 

 
Equipment provided but not manufactured by ACCES is warranted and will be repaired according to the terms 
and conditions of the respective equipment manufacturer's warranty. 
 

General

 

 
Under this Warranty, liability of ACCES is limited to replacing, repairing or issuing credit (at ACCES discretion) 
for any products which are proved to be defective during the warranty period. In no case is ACCES liable for 
consequential or special damage arriving from use or misuse of our product. The customer is responsible for all 
charges caused by modifications or additions to ACCES equipment not approved in writing by ACCES or, if in 
ACCES opinion the equipment has been subjected to abnormal use. "Abnormal use" for purposes of this 
warranty is defined as any use to which the equipment is exposed other than that use specified or intended as 
evidenced by purchase or sales representation. Other than the above, no other warranty, expressed or implied, 
shall apply to any and all such equipment furnished or sold by ACCES. 

Содержание PCIe-DIO-24H

Страница 1: ...n Diego CA 92121 858 550 9559 Fax 858 550 7322 contactus accesio com www accesio com MODELS PCIe DIO 24HS PCIe DIO 24H PCI Express 24 Channel Digital I OCard with Change of State Detection USER MANUAL File MPCIe DIO 24HS A1c ...

Страница 2: ...nt rights of ACCES nor the rights of others IBM PC PC XT and PC AT are registered trademarks of the International Business Machines Corporation Printed in USA Copyright 2015 by ACCES I O Products Inc 10623 Roselle Street San Diego CA 92121 All rights reserved WARNING ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE COMPUTER POWER OFF ALWAYS TURN COMPUTER POWER OFF BEFORE INSTALLING A BOAR...

Страница 3: ...rge for labor or parts not excluded by warranty Warranty commences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonable rates similar to those of other manufacturers in the industry Equipment Not Manufactured by ACCES Equipment provided but not manufactured by ACCES is warranted and will be repaired acc...

Страница 4: ...onnector Pin Assignments 15 Chapter 7 Specifications 17 Customer Comments 18 LIST OF FIGURES Figure 1 1 Block Diagram 6 Figure 3 1 Option Selection Map 9 Figure 6 1 50 Pin Male Header 15 LIST OF TABLES Table 1 1 Accessories 7 Table 5 1 Register Address Map 12 Table 5 2 Base 0 Port A DIO 12 Table 5 3 Base 1 Port B DIO 12 Table 5 4 Base 2 Port C DIO 13 Table 5 5 Base 3 DIO Port Direction Control Reg...

Страница 5: ...t bit Ports independently selectable for inputs or outputs Pull up resistors on DIO lines user configurable pull down 5V VCCIO 3 3V user configurable Fused VCCIO voltage available to the user on I O header Compatible with industry standard I O racks like Gordos Opto 22 Potter Brumfield Western Reserve Controls etc Applications Automatic test systems Laboratory automation Robotics Machine control S...

Страница 6: ...isabling and clearing the interrupts Each DIO line is buffered and capable of sourcing 32mA or sinking 64mA The VCCIO level is 5V or can be configured as 3 3V By default the DIO lines are pulled up with 10kΩ resistor networks to VCCIO DIO lines can also be configured as pulled down by moving a jumper DIO wiring connections are via the 50 pin header on the mounting bracket of the board This provide...

Страница 7: ...uick disconnect grounding tab on the mounting bracket Factory Options Extended temperature operation 40 to 85 C RoHS compliant version Optional Accessories CAB50F 6 Six foot ribbon cable assembly with 50 pin female connectors CAB50 6 Six foot ribbon cable assembly with a 50 pin female header connector and a 50 pin female edge connector STB 50 Screw terminal board ships with standoffs but can also ...

Страница 8: ...START RUN and type click OK or press c Follow the on screen prompts to install the software for this board Linux a Please refer to linux htm on the CD for information on installing under Linux Hardware Installation Please install the software package before plugging the hardware into the system Refer to the printed I O Quick Start Guide included with your board which can also be found on the CD fo...

Страница 9: ...manual VCC Select Position the jumper to select either 5VTTL logic or 3 3VDC logic Figure 3 1 Option Selection Map Bias Select Select 10k ohm pull up or pull down resistors per port using the provided jumpers on the card 50 Pin Header The latching 50 pin header has standard 0 100 spacing between pins and is keyed to prevent improper connections It can be used with standard IDC type ribbon cables A...

Страница 10: ...ects to pin 49 of the I O connector and is used to protect the card and PC power supply when used to power external module racks relay boards or for general purposes If an over current persists on a circuit protected by the resettable fuse it will open interrupting power to the circuit The amount of time it takes the fuse to act depends on the amount of over current and other conditions such as am...

Страница 11: ...o each function on each of the cards and the respective IRQs Alternatively Windows systems can be queried to determine which resources were assigned In these operating systems you can use either PCIFind or the Device Manager utility from the System Properties Applet of the control panel The card is installed in the Data Acquisition class of the Device Manager list Selecting the card clicking Prope...

Страница 12: ...se Address E Port C bit 3 IRQ Enable Read Write Base Address F IRQ Clear Write Table 5 1 Register Address Map Base Address 0 read write Port A DIO Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 PA7 PA6 PA5 PA4 PA3 PA2 PA1 PA0 Table 5 2 Base 0 Port A DIO Reading from this address will return the digital data on Port A Writing to this address will output the digital data on Port A Readback is suppo...

Страница 13: ...d 7 always reading zero Ports can be written to while configured as inputs When a Port is changed from input to output the last written value will be applied If a Port has never been written to the value on the Port s pins while in input mode will be applied to the Port when configured as an output This prevents the Ports pins from glitching when set as outputs Bit Assignment Code D0 Port C Lo C0 ...

Страница 14: ...Global Write any value to this address to disable all IRQ sources on the card Base Address E read write IRQ Enable Port C bit 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 0 IRQ Output 1 0 0 0 C3 Table 5 8 Base E Port C3 IRQ Enable At power up or reset all IRQ sources on the card are disabled To enable the C3 IRQ write a one to bit 0 A rising edge detected on bit 3 of Port C will generate an...

Страница 15: ...me Pin Signal Name 1 PC7 2 GND 3 PC6 4 GND 5 PC5 6 GND 7 PC4 8 GND 9 PC3 10 GND 11 PC2 12 GND 13 PC1 14 GND 15 PC0 16 GND 17 PB7 18 GND 19 PB6 20 GND 21 PB5 22 GND 23 PB4 24 GND 25 PB3 26 GND 27 PB2 28 GND 29 PB1 30 GND 31 PB0 32 GND 33 PA7 34 GND 35 PA6 36 GND 37 PA5 38 GND 39 PA4 40 GND 41 PA3 42 GND 43 PA2 44 GND 45 PA1 46 GND 47 PA0 48 GND 49 VCCIO 50 GND Table 6 1 Connector Pin Assignments Th...

Страница 16: ... C bit 0 PB7 I O Port B bit 7 PB6 I O Port B bit 6 PB5 I O Port B bit 5 PB4 I O Port B bit 4 PB3 I O Port B bit 3 PB2 I O Port B bit 2 PB1 I O Port B bit 1 PB0 I O Port B bit 0 PA7 I O Port A bit 7 PA6 I O Port A bit 6 PA5 I O Port A bit 5 PA4 I O Port A bit 4 PA3 I O Port A bit 3 PA2 I O Port A bit 2 PA1 I O Port A bit 1 PA0 I O Port A bit 0 VCCIO O 5V or optionally 3 3V via 0 5A resettable fuse ...

Страница 17: ... 2uA 0 8V 2uA High Inputs 3 5V 2uA 2 0V 2uA Low Outputs 0 55V 32mA 0 55V 24mA High Outputs 3 8V 32mA 2 4V 24mA Table 7 1 VCCIO Logic Levels Power Output VCCIO P3 pin 49 Environmental Operating Temperature 0 to 70 C optional 40 to 85 C Storage Temperature 55 to 150 C Humidity 5 to 95 RH without condensation Board Dimensions Length 6 6 Height 4 2 seated ...

Страница 18: ...lems with this manual or just want to give us some feedback please email us at manuals accesio com Please detail any errors you find and include your mailing address so that we can send you any manual updates 10623 Roselle Street San Diego CA 92121 Tel 858 550 9559 FAX 858 550 7322 www accesio com ...

Отзывы: