COMPRESSORS

COMPRESSORS

4.5

7.5

12
18

3

5
8

12

1.5

2.5

4
6

2.5

4
6

10

Table 1: Maximum length of leads (m)

Cross section

mm

2

Rated Operating Range

12-14 V

24-28 V

36-42 V

GD30FDC must always be powered through the dedicated electronic driver FDC1, which is supplied 
with the compressor as a separate device.

NEVER CONNECT THE COMPRESSOR’S HERMETIC PINS (FUSITE) TO THE TERMINALS OF A BATTERY OR 
ANY OTHER DC OR AC SOURCE DIRECTLY.

DO NOT TRY TO FIT AN ELECTRONIC DRIVER OTHER THAN THE FDC1. THE COMPRESSOR WILL NOT 
OPERATE AND IRREVERSIBLE DAMAGE MAY OCCUR.
 
The FDC1 driver is directly connected to the battery poles as well as to the compressor pins. It checks 
battery voltage and adjusts itself to the voltage value for proper compressor operation, or switches 
itself off if the battery voltage is not adequate. The driver also controls the compressor speed.

ALWAYS RESPECT THE POLARITY OF THE BATTERY WITH THE POWER INPUT TERMINALS OF THE 
ELECTRONIC DRIVER

The unit is protected against damage caused by wrong polarity of the supply,. The compressor will not 
run correctly if it’s wrongly connected.

“-“ POWER INPUT TERMINAL OF THE ELECTRONIC DRIVER  SHOULD BE REFERRED TO THE  CHASSIS OF 
THE VEHICLE AS WELL AS THE APPLIANCE FRAME*

A FUSE MUST BE PLACED BETWEEN THE  “+” POLE OF THE BATTERY OR DC POWER SUPPLY AND THE “+” 
POWER INPUT TERMINAL OF THE ELECTRONIC DRIVER*

12V SYSTEMS: 30A FUSE
24V SYSTEMS: 15A FUSE
42V SYSTEMS: 10A FUSE

In some special vehicles chassis is connected to “+” terminal of the battery instead of “-“ terminal 

(positive reference systems). In such cases “+” should be understood as “-“  and vice-versa.

In systems powered by a variable DC source, the fuse should be selected following the rules above 
mentioned, considering the maximum voltage at the variable DC Source.

To avoid excessive voltage drop in the leads, their length and cross section must be related to the 
voltage supply as indicated in Table 1.

2. 

WIRING AND CONNECTIONS

General rules

Voltage drop in the power leads

September 2006

3

GD30FDC  User Manual

DISTRIBUTED  by  PROCOLD S.r.l. - Italy  -  Tel:  (+39) 0161 42 44 52   -  [email protected]

Содержание GD30FDC

Страница 1: ...Procold S r l info procold it www procold it...

Страница 2: ...COMPRESSORS COMPRESSORS...

Страница 3: ...this one will go far COMPRESSORS COMPRESSORS...

Страница 4: ...ACC s D series which has been successfully present in the market since 1984 and has had sales of 15 million units GD30FDC can be powered at any voltage within the 12 to 42V DC range and is designed f...

Страница 5: ...es with no design efforts FDC1 electronic driver includes also Sleep and Sleep Energy Saving as programming option which are plug in systems specially conceived for mobile air conditioners avoiding an...

Страница 6: ...LECTRONIC DRIVER The unit is protected against damage caused by wrong polarity of the supply The compressor will not run correctly if it s wrongly connected POWER INPUT TERMINAL OF THE ELECTRONIC DRIV...

Страница 7: ...agram 3 THE SERIAL PORT INTERFACE Install a LED to display the intervention of any alarm Set up either the compressor speed or the battery protection level through physical connections between IN1 IN2...

Страница 8: ...thin 33 and 42 4V The compressor can be powered by a variable DC source as for instance a photovoltaic panel in which the output voltage strongly depends on the intensity of sunlight radiation In thes...

Страница 9: ...programming package The cut out battery voltage at which the driver stops operating and the cut in battery voltage at which driver re starts operation after a cut off values are set up by connecting t...

Страница 10: ...and 42V for 12V 24V and 42V systems respectively A linear function of the battery voltage in the range between the cut in and the maximum nominal voltages This option is particularly useful for eutec...

Страница 11: ...speed is controlled by an Electronic Integral Manager of the appliance EIM permanently connected to the electronic driver FDC1 through the SPI using its serial communication capability The EIM reads...

Страница 12: ...lave mode Internal protection choose between normal and special voltage systems External protection Protection values are shown in Table 3 of point 5 External protection is incompatible with external...

Страница 13: ...e In case of battery protection the number of automatic attempts to restart is unlimited Once the sequence of automatic attempts to restart the compressor is finished the unit will remain permanently...

Страница 14: ...TRONIC DRIVER MUST ALWAYS BE GUARANTEED Table 6 shows the recommended cooling method for a standard condensation temperature of 55 C The table should be taken as a recommendation as the only way to va...

Страница 15: ...Alarm LED 15V 25mA electronic thermostat 5V 25mA Electronic Integral Manager Serial Port Interface SPI RS 232 serial port 2 digit 4 level switcher Alarm LED Compressor speed selection Battery protecti...

Страница 16: ...V systems 11 5 24 5 38 5 V Cut in 12 24 42 V systems 10 0 22 0 36 0 V 3 minutes thermostat delay on rpm W kCal h W kCal Wh W W A 1500 32 28 26 1 07 1 24 2 19 2000 46 40 36 1 11 1 28 3 03 2500 58 50 46...

Страница 17: ...78 112 142 168 190 73 106 134 158 179 47 64 83 100 116 1 95 2 05 2 00 1 95 1 90 1 57 167 1 62 1 59 1 54 3 88 5 29 6 88 8 35 9 70 100 142 180 214 244 94 134 170 202 230 52 71 92 112 130 2 23 2 33 2 28...

Страница 18: ...house condensing units to the commer cial refrigeration market in mor e than 80 countries worldwide ACC Spain continues with the experienceand leadership acquired by Cubigel to improve the quality of...

Страница 19: ...COMPRESSORS COMPRESSORS NOTES DISTRIBUTED by PROCOLD S r l Italy Tel 39 0161 42 44 52 info procold it...

Страница 20: ...s ACC Spain S A P O Box 3283 08200 Sabadell Spain Phone 34 93 746 41 71 Fax 34 93 712 28 64 E mail commercialcold accomp it www the acc group com 0504 DISTRIBUTED by PROCOLD S r l Italy Tel 39 0161 42...

Отзывы: