AEC-6890M Manual
10
Please follow the instructions below to get a suitable RAID DIP switch setting.
1. Normal Mode --- In this mode you should set DIP switch 1 and 2 as
OFF. The default is OFF.
O N
1 2
2. Striping Mode (RAID 0) --- RAID 0 is 2 hard drives that store
striping data, but appears as a single volume in the computer. This
mode is formed by setting DIP switch 1 as OFF and 2 as ON.
2.5 DIP Switch Setting
RAID configurations must be set on AEC-6890M’s DIP switch. However, after in-
stalling hard drives to the serial ports, do not arbitrarily change the positions other-
wise the adapter may misunderstand and the data may be lost.
3. Mirroring Mode (RAID 1) --- RAID 1 is a pair of hard drives that
store mirroring data, and is regarded as a single volume. This mode
is formed by setting DIP switch 1 as ON and 2 as OFF.
NOTICE: The serial ATA cable is used to transfer data of very high
frequency. It is suggested not to connect and disconnect it often, for the
connector is easily damaged.
O N
1 2
O N
1 2
O N
1 2