Battery Saving [
bAttSAvE
]
1. Save ~20% of your battery by dimming the display after some time. It’ll return to its
original brightness when the scale senses objects on it.
2. The number indicates the amount of time before the scale enters battery saving mode.
3. Tap the tare button to toggle through the options.
4. Press and hold tare button for 1 second until the next setting, [
PrE_inFu
], is shown on LED to
confirm the selected option.
Pre-Infusion Time Out [
PrE_inFu
]
1. Determines when the scale times out in all three of the Auto-Start modes. This is most
useful for long pre-infusion times and resolves the timeout that sometimes happens for
slow pre-infusion times.
2. The number indicates the time in seconds it will take for the scale to reset if no espresso flow or
weight is detected.
3. Tap the tare button to toggle through the options.
4. Press and hold tare button for 1 second until the next setting, [
SEnSE
], is shown on the LED to
confirm the selected option.
Auto-Start Sensitivity [
SEnSE
]
1. Minimum weight is decreased for more sensitivity. This is ideal for slower espresso shots in the
droplet icon modes. Stability depends on environmental noise. The previous firmware started
the timer at ~0.6 g into an espresso shot.
2. The number indicates the sensitivity of flow detection in the droplet icon modes. Smaller value
indicates higher sensitivity, but is recommended only for stable working environment.
3. Tap the tare button to toggle through the options.
4. Press and hold tare button for 1 second until the next setting, [
Auto_rES
], is shown on the
LED to confirm the selected option.
Chapter 4: Configuration 27