Appendix

 

Buttons

Function

Example

Turn On

Press and hold to turn on the scale.

Turn Off

Double tap to turn off the scale.

Switch Mode

While the scale is turned on, press and hold 

for 2 seconds to switch modes.

Start / Stop / Reset Timer While in Timer Mode, tap to start/stop/reset 

timer.

Back

While in Settings Menu, tap to go back to 

Weighing Only Mode.

Tare 

Tap to perform tare operation.

Toggle Units

Press and hold to switch between gram 

and ounce.

Reset Mode

Double tap to reset a mode. This zeroes the 

weight and sets the timer to 0:00.

Toggle Settings Option

While editing a setting, tap to scroll through 

its options.

Confirm

While editing a setting, press and hold for 2 

seconds to confirm the option selected.

Enter Calibration Mode

While in Weighing Only Mode, rapidly tap 

to enter Calibration Mode.

14

Tare 

Button

Power 

Button

Содержание AP009

Страница 1: ...Acaia Pearl User Manual FW 1 0 010 AP007 AP008 AP009...

Страница 2: ...e Battery Indicator Calibration Flow Rate Indicator Mode Introduction Mode 1 Weighing Only Mode Mode 2 Dual Display Mode Mode 3 Pour Over Auto Start Timer Mode Mode 4 Portafilter Mode Mode 5 Beverage...

Страница 3: ...in personal injury or physical damage Thank you for choosing one of our scales The Acaia Pearl is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience...

Страница 4: ...Modes Toggle Units Place the scale on a stable and vibration free surface at a preferably horizontal location 4 Press to turn on the scale Double tap to turn off the scale Tap to tare zero the weight...

Страница 5: ...e has cooled Turn on the Acaia scale Make sure the scale is in Weighing Only Mode and the unit is set to gram then tap the T button rapidly Keep tapping the T button until CAL is shown on the display...

Страница 6: ...5 g per second the last three LEDs will light up with enhanced brightness indicating a high flow rate To provide thresholds for ideal flow rates the first pair of the brighter LEDs represents 2 5 g p...

Страница 7: ...ress and hold Tare button Reset Mode Double tap Tare button Switch Mode Press and hold Power button In the Dual Display Mode the scale displays 0 00 0 0 with a timer left and weight right There are tw...

Страница 8: ...e weight In grams the LED display shows 0 00 0 0 with the timer on the left and the weight on the right In ounces the LED display shows 0 00 0 00 with the timer on the left and the weight on the right...

Страница 9: ...e carafe cup on the scale press and hold the Tare button to go to the next step Put the filter dripper on the carafe cup press and hold the Tare button to save the dripper weight Measure the amount of...

Страница 10: ...tness Setting bright 1 2 3 4 2 Battery Saving Setting bAttSAvE 30 90 180 Off 90 Zero Tracking Setting trAcE 0 5 d 1 d 2 d 3 d Off 2 d Key Sound Setting bEEP On Off On Weighing Filter Setting FiLtEr Fa...

Страница 11: ...f the scale Acaia Pearl is allowed to compensate fluctuations of up to 3 d according to the industrial weighing guidelines 3 Off It is not recommended to turn off Zero Tracking as the zero indication...

Страница 12: ...ng Only Mode Setting NodE_1 1 The default setting is On 2 On Mode enabled 3 Off Mode disabled Dual Display Mode Setting NodE_2 1 The default setting is On 2 On Mode enabled 3 Off Mode disabled Pour Ov...

Страница 13: ...20 seconds 2 In Pour Over Auto Start Timer Mode after a cup is removed the timer and weight will automatically reset This setting gives you options on how long to wait before resetting 3 If this setti...

Страница 14: ...p to go back to Weighing Only Mode Tare Tap to perform tare operation Toggle Units Press and hold to switch between gram and ounce Reset Mode Double tap to reset a mode This zeroes the weight and sets...

Страница 15: ...uto tare when a stable weight is placed on the weighing pan LED Indicators Power Button Tare Button 15 Charging Low Battery Indicator This indicator turns on when the battery is charging and turns off...

Страница 16: ...acity Error 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please calibrate in a stable environment free of wind vibration etc Error 802 Unable to tare becau...

Страница 17: ...peatability 0 1 g Linearity 1 d d 0 1 g 0 5 g Indication Limit 2060 0 g 72 660 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 1100 mAh Battery Life 30 40 Hours Display 8 digit LED B...