acaia AL010 Скачать руководство пользователя страница 19

Weighing Resolution Setting [ rESoL ]  

 1. The Weighing Resolution is automatically set to [ dEFAUL ]: the division is 0.1 g/0.002 oz.

 2. Tap the Tare button to switch the Weighing Resolution between [ dEFAUL ] and [ hiGh ].

 3.  When the Weighing Resolution is set to high, the division will be 0.01 g/0.0005 oz. The default 

display will show [ 0.00 ] when the scale is set to grams, and [ 0.0000 ] for ounces in Weighing 

Mode.

      

 Note: After setting Weighing Resolution to high, the default display will show [ 0:00  0.00 ] with timer 

in Dual Display Mode and Auto Start Modes.

Weighing Filter Setting [ FiLtEr ] 

1.  The Weighing Filter Setting determines the speed at which the load receptor responds to weight 

and determines the weighing value. The larger the number, the more stable but slower the 

weighing result will be. The number shown on the LED display indicates the current filter setting.

2. Press the Tare button to change the parameter.

Zero Tracking Setting [ trAcE ] 

1. Zero Tracking is a function for automatically maintaining the zero indication within certain limits.

2.  Off: It is not recommended to turn off Zero Tracking because the zero indication can drift easily as 

the room temperature changes.

3.  0.5 d~3 d: For example, for standard resolution each division is 0.1 g, 3 d = 0.3 g. When Zero 

Tracking is set to be 3 d, any initial weight between ± 0.3 g on the weighing pan will be zeroed out 

gradually.

4. 2 d is recommended in general for the Acaia Lunar.

Zero Range Setting [ 0.rAnGE ] 

1.  The Zero Range Setting determines the range for which the Tare button executes zero operation 

instead of tare operation.

2.   When  Zero  Range  is  set  to  2,  the  range  for  zero-setting  will  be  2%  of  the  capacity,  i.e.,  ±  40  g  for                       

    Acaia Lunar. By pressing the Tare button, any weight within ± 40 g is zeroed out by zero operation    

    while any weight that lies outside the range is tared out by tare operation.

3.  If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., ± 2 kg for 

Acaia Lunar. Therefore, instead of tare operation, zero operation would be executed in this setting 

whenever the Tare button is pressed.

     

Notice: The difference between zero operation and tare operation is that zero operation would simply 

ignore the weight and display as 0 while tare operation would deduct the weight from the weighing 

result. However, zero operation does not increase the scale capacity.

  Bluetooth Setup Setting [ bt_SEt ]  

1. Off: Bluetooth disabled. The scale does not allow any Bluetooth connection.

2. On:  Bluetooth enabled. The scale allows Bluetooth connection. The user may connect the scale 

    with Acaia apps.

Reset to Default Setting [ rESEt.d ]

Select [ YES ] to reset all settings to default value.

19

Содержание AL010

Страница 1: ...Acaia Lunar User Manual AL008 AL009 AL010 FW 1 0 009...

Страница 2: ...ator Brewing with Flow Rate Indicator Tare Save Mode Introduction Mode 1 Weighing Mode Mode 2 Dual Display Mode Mode 3 Timer Starts with Flow Mode Mode 4 Auto Tare Timer Starts with Flow Mode Mode 5 A...

Страница 3: ...njury or physical damage Thank you for choosing our scale The Acaia Lunar is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience Start by checking yo...

Страница 4: ...e the scale on a stable and vibration free surface at a preferably horizontal location 4 Press to turn on the scale Double tap to turn off the scale Press to tare zero the weight Press and hold to swi...

Страница 5: ...Power button until the battery percentage is displayed You can also check the battery level by connecting the scale to Acaia Apps Product Care Information Turn on the Acaia scale Turn on scale Make su...

Страница 6: ...ed brightness indicating a high flow rate During an espresso brew the Flow Rate Indicator will display the highest peak flow rate of this brew with a single bright LED The Flow Rate Indicator can be a...

Страница 7: ...on the display When brewing is completed and the cup is removed from the scale the display will flash to show the final beverage weight and the average flow rate of the brewing The Flow Rate Indicator...

Страница 8: ...stable The weight is stored as a preset container weight Press and hold Tare button for 0 5 second The scale will display the weight to be deducted You may continue using your scale The net weight is...

Страница 9: ...e funtion is supported in this mode There are two different weighing units in Dual Display Mode gram and ounce In grams the LED display shows 0 00 0 0 In ounces the LED display shows 0 00 0 000 The ti...

Страница 10: ...the flow of espresso the timer starts The timer will stop when the flow stops Please note The flow detection mode is designed to detect the slow trickle of a shot of espresso The timer may not trigge...

Страница 11: ...would like to measure the time of the shot starting from the first few drops of espresso When the weight reading is stable the scale will perform the auto tare operation After the scale detects the e...

Страница 12: ...ht is placed on the scale Tare Weight Tare function starts when a stable weight is placed on the scale Stop Timer The timer will stop when flow is no longer detected Reset Mode Double tap Tare button...

Страница 13: ...scale Reset Mode Double tap Tare button Switch Mode Press and hold Power button The LED display shows 0 0 with the weight in grams The LED display shows 0 000 with the weight in ounces Display In this...

Страница 14: ...al beverage weight and the average flow rate of the brewing If the scale remains idle for 30 seconds it will reset the timer and perform the tare operation This feature is ideal for streamlining bar w...

Страница 15: ...ttings The first setting is SLEEP 3 Please refer to the following table for key operations Configuration Enter Settings Action Operation Next Setting Tap Tare button Enter Setting Press and hold Tare...

Страница 16: ...to Start Timer Mode Setting NOdE_5 On Off On Auto Tare Mode Setting NOdE_6 On Off On Flow Rate Indicator Setting FLorAtE d Default Grad Off Default Average Flow Rate Setting Avg FLo On Off On Weight S...

Страница 17: ...of time in seconds before the scale enters battery saving mode 3 Tap the Tare button to toggle through the options Default Unit Setting Unit The Default Weighing Unit is set to grams if 9 is selected...

Страница 18: ...e Weight Stable Indicator on the bottom left of the display lights up when the weight is stable 3 Off Weight Stable Indicator disabled Auto Reset Setting Auto_rES 1 After a cup is removed the timer an...

Страница 19: ...vision is 0 1 g 3 d 0 3 g When Zero Tracking is set to be 3 d any initial weight between 0 3 g on the weighing pan will be zeroed out gradually 4 2 d is recommended in general for the Acaia Lunar Zero...

Страница 20: ...on Tare Tap to tare weight Tare and Reset Timer While in Auto Start Modes double tap to zero weight and reset timer Save Subtract Press and hold for 2 seconds to save the container weight Press and ho...

Страница 21: ...es The indicator also lights up during software update to indicate data transfer Button Pressed Indicator This indicator turns on when a button is pressed Auto Start Timer with Flow Indicator When the...

Страница 22: ...he weight is over the maximum capacity Under load the weight is under the minimum capacity 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please calibrate in...

Страница 23: ...n Limit 2060 g 72 66 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 1100 mAh Battery Life 30 40 hours Display 8 digit LED Material Aluminum Acrylic Surface Anodized aluminum coating...

Страница 24: ...l rights reserved No part of this manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...

Отзывы: