background image

- 3 - 

GENERAL INFORMATION 

 

The A.C.A. Allertor 125 is a powerful, rotating, directional 
siren with a unified design that is both compact and 
weatherproof.  The output of 126 decibels at 100 feet is 
radiated to an effective 70 DB range of 4500 feet, thus giving 
a total circular coverage of 2.2 square miles per siren. (Federal 
CD Guide, March 1964.) 
 
The single 10 HP motor produces the sound through direct 
drive rotor-stator design and also rotates the entire assembly at 
3.5 RPM through a direct drive worm and spur gear 
combination. 
 

Model CD1-103 Size B is a two-signal siren 

 

Model CD-107 Size 3B3 produces two or three signals 

 
The standardized signals are as follows: 
 

1 - ALERT, a dual tone sustained tone scale signal 

 

2 - ATTACK - TAKE COVER, a dual tone wailing slowly 

up and down tone scale signal 

 

3A - FIRE, a dual tone wail of different timing than the 
attack signal 

 

3B - FIRE, a dual tone yelp or rapid down tone scale signal 
with a pause between each tone blast. 

 
All signals are precisely controlled by a solid state integrated 
circuit master control device or a radio decoder-timer. 
 
When specified, the electrical controls associated directly with 
the siren are prewired and contained inside a weatherproof 
metal enclosure, which may be mounted in any convenient 
location.  Electrical installation is simple and straightforward. 
 
A variety of signal sources may be employed to initiate 
operation of a siren or siren system including - 
 
 

1 - Direct mechanical switch 

 

2 - Telephone relay system  

 

3 - Radio relay system  

 

4 - Program timer  

 

5 - Any combination of the above 

 

SPECIFICATIONS 

 
Weight: 

Allertor 125 (2 signal).………….……………….425 lbs. 

Allertor 125 (3 signal)………………..……….…450 lbs. 

Dimensions: 

Overall assembly……………………7 ft. long, 3 ft. wide, 

 

5 ft. high   

ACOUSTICAL DATA 

 
Output level………………………………126 DB at 100 feet 
Output frequencies: 

Standard dual tone…………………………523/698 hertz 

Special single tone………………………………465 hertz 
Special single tone………………………………698 hertz 

Output cutoff (resonant) frequency…………………..80 hertz 
Sound dispersal beam……………………10' above horizontal 

 

15' below horizontal 

 

30' wide horizontally 

 

MOTOR DATA 

 
For compression- 

Modulation……………………10 hp, 3 phase, ball bearing, 

Semi-enclosed, induction 
motor. High torque. Direct 
coupled to rotor and gear 
reducer. Single phase 
available as special. 

Air compression..…Direct drive back curved fin impeller. 

Electrical 

Requirements………………...230 volt, 3 phase - 31 amp. 

 

460 volt, 3 phase - 15.5 amp. 
208 volt, 3 phase - 36 amp. 
240 volt, 1 phase - 60 amp. 

ROTATION 
 
Drive…………………..Direct drive through a worm gear 

box, coupled through a torque-
limiting device. 

Speed………………………………………………3.5 RPM 
 

ITEMS FURNISHED 

 
Wood crated siren assembly with horn detached. 
 
When specified, pre-assembled and wired control panel 
cabinet with telephone relay or radio. 
 
When specified, pole mount, roof mount or parapet mount. 
 

ITEMS REQUIRED FOR INSTALLATION 

 
Suitable mount (pole, platform, etc.) if not ordered with siren. 
 
Electrical conduit and wire for interconnecting to control 
cabinet and power source.

STORAGE 

 

The unit is weather resistant as shipped and may be stored either 
indoors or outdoors provided there is no danger of submergence in 
water or other damaging fluids, or subject to possibility of vandalism. 

Содержание ALLERTOR 125

Страница 1: ... 1 INSTALLATION OPERATION MAINTENANCE And PARTS MANUAL 4801 W Woolworth Ave Milwaukee WI 53218 Phone 414 358 8000 Fax 414 358 8008 ALLERTOR 125 ROTATING DIRECTIONIAL SIREN ...

Страница 2: ...SASSEMBLY REPAIR REPLACEMENT AND REASSEMBLY 11 PREPARATION FOR RESHIPMENT 11 STORAGE 11 PARTS LIST 12 14 Control Panel for 3 Phase 2 Signal Siren 12 Control Panel for Single Phase 2 Signal Siren 13 Control Panel for 3 Phase 3 Signal Siren 14 Siren Assembly 15 17 ILLUSTRATIONS Figure Page 1 Roof Mount 5 2 Parapet Mount 5 3 Chimney Mount 5 4 Tower or Tank Mount 5 5 Siren Support Platform 5 6 Work Pl...

Страница 3: ...ing 1 Direct mechanical switch 2 Telephone relay system 3 Radio relay system 4 Program timer 5 Any combination of the above SPECIFICATIONS Weight Allertor 125 2 signal 425 lbs Allertor 125 3 signal 450 lbs Dimensions Overall assembly 7 ft long 3 ft wide 5 ft high ACOUSTICAL DATA Output level 126 DB at 100 feet Output frequencies Standard dual tone 523 698 hertz Special single tone 465 hertz Specia...

Страница 4: ...not mount siren too high so that the sound goes over the top of the area In lieu of a suitable existing structure for mounting a cedar pole approximately 40 50 feet long and sunk 8 feet deep is a generally recommended mount Refer to the illustrated mounting layouts for details Any tall building trees hills or other obstructions will tend to create a barrier which will produce a deadened area behin...

Страница 5: ...sign will be dictated by building construction and height desired CHIMNEY MOUNT FIGURE 3 A sturdy chimney may provide a convenient support for mounting the siren The possibility of corrosive or staining smoke should be considered when this type of installation is planned Use 4 heavy wall galvanized pipe to a maximum height of 10 feet above the top of the chimney Use larger pipe for greater height ...

Страница 6: ... 6 ...

Страница 7: ... 7 ...

Страница 8: ... and not the eyebolt on the siren The gear reducer end of the siren should lead the way up as the siren and pole are raised to the vertical position see Figure 8 c The fiberglass horn may be assembled to the compression chamber before erection provided no weight is put on the horn and it does not interfere with erection d With the pole and siren in final position proceed with electrical connection...

Страница 9: ...nstalled under the base in the center of the assembly This bearing has an external grease fitting and has been lubricated at the factory so no additional lubricant is necessary for one year When greased one shot of the grease gun is sufficient If excess flows from the seals remove it from inside the base with a rag Use Molub Alloy 171 graphite grease manufactured by the Imperial Oil and Grease Co ...

Страница 10: ...r stator 11 De ice with hot antifreeze or hot air blower Do not use flame near fiberglass B Siren operates with difficulty or erratically POSSIBLE CAUSE CORRECTIVE PROCEDURE 1 Siren air intake clogged 1 Clear obstruction 2 Build up of foreign material between siren 2 Disassemble housing and clean Air gap rotor and stator should be 025 inch or more 3 Rotation mechanism binding 3 Inspect to determin...

Страница 11: ...T AND REASSEMBLY The siren s physical design is such that it precludes most mechanical problems other than those caused by natural disasters or violent physical damage The siren configuration is constructed from reinforced fiberglass and bolted together to form a weatherresistant enclosure for all moving parts The parts drawing Figure 15 illustrates component placement Upon removal of the fibergla...

Страница 12: ...ON NO REQ D 12 20100 CONTROL PANEL ASSEMBLY Complete REF 1 20101 ENCLOSURE NEMA 12 Furnas for maometic starter 14EF32AC71 1 2 20102 PANEL Interior mounting 1 3 20103 STARTER Magnetic Furnas size 1 3 4 NEMA 1 4 20104 SWITCH Operating optional 1 5 20105 OVERLOAD Bi metal 31 5 amp for 230V siren 1 6 20106 COUNTER 230 volt optional 1 7 20108 BLOCK Terminal 1 ...

Страница 13: ...mounting 1 3 20203 STARTER Magnetic single phase size 2 NEMA 1 4 20204 OVERLOAD Bi metal 60 axnp for 230V siren 2 5 20205 RELAY Current sensing for No 10234 motor for start capacitor 1 6 20206 CONTACTOR Start 1 7 20207 CAPACITOR Start for No 10234 motor 4 8 20208 CAPACITOR Run for No 10234 motor 3 9 20209 COUNTER 230 volt optional 1 10 20211 BLOCK Terminal 1 11 20212 SWITCH Manual optional 1 ...

Страница 14: ...MBLY Complete REF 1 20301 ENCLOSURE NEMA 12 Furnas for magnetic starter 22EF32A71 1 2 20302 STARTER Magnetic Furnas 1 3 4 size reversing type includes mounting panel 1 3 20303 SWITCH Operating optional 1 4 20304 OVERLOAD Bi metal special type from A C A 3 5 20305 COUNTER 230 volt optional 1 6 20306 BLOCK Terminal 1 ...

Страница 15: ... 15 ...

Страница 16: ... Drive with sprocket 1 12C AL 125 12C KEY Drive shaft 1 12D AL 125 12D GASKET 1 13 AL 125 13 LIMITER ASSEMBLY Torque includes bushing and arm 1 14 AL 125 14 COLLAR 5 8 in I D 1 15 AL 125 15 SPRING Torque setting 1 16 AL 125 16 COVER Chain 1 17 AL 125 17 DRIVE ASSEMBLY Base rotator 1 17H Coml CHAIN Base rotator No 35 standard 68 11 16 in plus 1 connector 1 18 AL 125 18 BEARING Upper rotator 1 1 4 i...

Страница 17: ...H40 Coml SCREW Hex hd cap 3 8 18 x I in 6 H41 Coml WASHER Internal star 3 8 in 6 H42 Coml SCREW Hex hd cap 3 8 18 x 1 1 4 in 1 H43 Coml NUT Hex 3 8 18 8 H44 Coml SCREW Hex hd cap 3 8 18 x 1 1 2 in 1 H45 Coml SETSCREW 5 16 18 x 5 16 in 2 H46 Coml NUT Brass No 10 32 6 H47 Coml NUT Hex hd jam 1 2 13 2 H48 Coml SCREW Hex hd cap 5 8 11 x 2 1 4 in 4 H49 Coml WASHER Flat 5 8 in 4 H50 Coml WASHER Internal...

Отзывы: