background image

4

MANUAL CODE SFT2311X1

MODEL

AC-SFT3
AC-SFT7

PRODUCT

THERMOFORGE T3
THERMOFORGE T7

UPC-A

819137024489
819137024502

Содержание THERMOFORGE Series

Страница 1: ...1 USER MANUAL THERMOFORGE SERIES ENVIRONMENTAL VPD HEATER...

Страница 2: ......

Страница 3: ...oduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL su...

Страница 4: ...4 MANUAL CODE SFT2311X1 MODEL AC SFT3 AC SFT7 PRODUCT THERMOFORGE T3 THERMOFORGE T7 UPC A 819137024489 819137024502...

Страница 5: ...tents Installation Powering and Setup Cleaning UISTM Platform Connecting to UIS Controllers Programming Other Settings FAQ Other AC Infinity Products Warranty Page 5 Page 6 Page 10 Page 11 Page 12 Pag...

Страница 6: ...ct if its cord malfunctions or is damaged in any manner Contact our customer service for support 7 Do not use this product outdoors in direct sunlight or expose it to weather or elements 8 This produc...

Страница 7: ...or allow fingers or foreign objects to enter any ventilation or exhaust openings as it may cause electric shock fire or damage to this product Do not block or tamper with this product in any manner w...

Страница 8: ...Clean this product regularly only as instructed in this manual Do not use gasoline thinners solvents ammonias or other chemicals for cleaning 24 There may be a trace of smoke or odor when this produc...

Страница 9: ...e front of this heater READ AND SAVE THESE INSTRUCTIONS PRODUCT WARNING DO NOT attempt to repair this product yourself All service and or repairs must be done by an authorized technician and or electr...

Страница 10: ...ontrol TARGETED HEATING Flexible duct tubing enables focused heat distribution within your growing environment PWM CONTROL Offers 10 heat and fan levels while delivering an energy efficient performanc...

Страница 11: ...11 PRODUCT CONTENTS SPACE HEATER x1 SENSOR PROBE x1 UIS EXTENSION CORD M M x1 PROBE MOUNT x4 HOOK AND LOOP TIE x4 DUCT EXTENSION x1...

Страница 12: ...Place your heater outside of your grow tent Route the duct tube through the lowest duct port available and into your grow tent DUCT EXTENSION You may insert the end of your heater s duct tube into th...

Страница 13: ...STEP 1 Plug the sensor probe into the 3 5mm jack located at the back of your heater Route the probe head to your plant s canopy for the most accurate readings STEP 2 Plug your heater s power plug into...

Страница 14: ...14 POWERING AND SETUP CORD MANAGEMENT You may wrap the power cord around the spool hidden underneath the heater as needed...

Страница 15: ...15 CLEANING STEP 1 Unplug your heater STEP 2 Twist the intake vent cap off of your heater STEP 3 Wipe off any dust and debris from the grille and vent cap using a damp cloth Set aside to dry as needed...

Страница 16: ...t Your grow system can be regulated using your controller hub or remotely on the AC Infinity app paired with compatible controllers where you will have access to automation programming and climate dat...

Страница 17: ...iquids and dust Your UIS controller will override all onboard settings assume control parameters must be adjusted on the controller and shut off your heater s display and touch functions when connecte...

Страница 18: ...e last hour 11 ALERT ICONS Displays alerts and statuses of the controller including the controller lock CLIMATE alert and TIMER alert 9 USER SETTING Displays the value of your current mode Use the up...

Страница 19: ...MODE Your heater will not run while in this mode The OFF Mode setting also serves as the minimum level the other modes will run at while triggered OFF MINIMUM LEVEL Your heater will run at the level...

Страница 20: ...as in the AUTO Mode VPD Mode TIMER TO OFF Mode and CYCLE Mode Do not set the ON Mode figure to zero or your heater will turn off when it s triggered ON in all modes ON MODE Your heater will actively r...

Страница 21: ...will gradually ramp up to the level set in ON Mode If the probe s reading rises above this trigger point your heater will gradually slow down to a stop or at the level set in OFF Mode LOW TEMPERATURE...

Страница 22: ...or falls below this threshold Once triggered your heater will gradually ramp up to the level set in ON Mode If the probe s reading falls below this trigger point your heater will gradually slow down t...

Страница 23: ...level set in OFF Mode your heater will run at that level after the end of the countdown The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown is shown on the...

Страница 24: ...first set a duration for it to activate Then press the mode button again and set a duration for your heater to deactivate When your heater is activated it will run at the level set in ON Mode When it...

Страница 25: ...OFF MODE Your heater will not run while in this mode The OFF Mode setting also serves as the minimum level the other modes will run at while triggered OFF MINIMUM LEVEL Your heater will run at the le...

Страница 26: ...as well as in the TIMER TO OFF Mode and CYCLE Mode Do not set the ON Mode figure to zero or your heater will turn off when it s triggered ON in all modes ON MODE Your heater will actively run at the...

Страница 27: ...level set in OFF Mode your heater will run at that level after the end of the countdown The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown is shown on the...

Страница 28: ...set a duration for it to activate Then press the mode button again and set a duration for your heater to deactivate When your heater are activated it will run at the level set in ON Mode When your hea...

Страница 29: ...ng button Press the setting button to turn the display off Pressing the setting button again will turn the display back on Programs will still run in the background while the LCD screen is off F C SET...

Страница 30: ...Adjusts the relative humidity reading the sensor probe is measuring Press the up or down button to increase or decrease the data figure in 1 increments The calibration cycle ranges from 10 to 10 and...

Страница 31: ...triggered functions or alarms ALARM Flashes and beeps with an alert if the temperature VPD meet the trigger point set in the app AUTO MODE ALERT Flashes whenever the AUTO Mode trigger activates your...

Страница 32: ...temperature exceeds 194 F The heater function and controller buttons will be disabled until the internal temperature cools below 185 F The fan function will not be disabled during this emergency shut...

Страница 33: ...ode While your heater is locked no parameters may be adjusted nor will you be able to switch modes or functions Holding the setting button again will unlock your heater HOLD FACTORY RESET Holding the...

Страница 34: ...HOLD MUTE ALARMS Press any button to mute alarms PRESS ANY BUTTON RESET TO OFF DEFAULT Holding the up and down buttons together for 2 seconds will reset the value of your current mode or setting to d...

Страница 35: ...obe plugged into your controller will override the heater s sensor Q A How should I route my heater s ducting Set your heater outside of your grow tent and channel the ducting through one of its lower...

Страница 36: ...midity and VPD levels Humidifiers The CLOUDFORGE series is a line of humidifiers designed to produce optimal humidity levels for successful plant growth The onboard smart controls feature 10 intensity...

Страница 37: ...uring that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the pr...

Страница 38: ...part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in...

Страница 39: ......

Страница 40: ...www acinfinity com...

Отзывы: