![AC Infinity ARKTICA Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/ac-infinity/arktica-series/arktica-series_user-manual_454743017.webp)
17
PROGRAMMING
AUTO MODE: HIGH TEMP.
In this mode, press the up or down button to set
a high temperature trigger. The fans will activate
if the probe’s measured temperature exceeds
the temperature you have set in this mode. The
activated fans will slowly increase in speed until
it reaches the speed set in ON Mode. Whenever
the measured temperature falls below your set
temperature, the fans will slowly decrease in speed
until the fans stop. You may also hold the up and
down button simultaneously to turn off this trigger, in
which the digits under settings will show OFF.
ALARM SETTING: HIGH TEMP.
In this settings mode, press the up and down
button to set a high temperature alarm. The
alarm will activate if the probe’s measured
temperature exceeds the temperature you have
set in this mode. When the alarm triggers, the
fan will start spinning gradually to max speed
regardless of your other settings. You may also
hold the up and down button simultaneously
to turn off this alarm, in which the digits under
settings will show OFF. You will need to be in
AUTO, ON, or TIMER mode for this alarm to be
able to activate.
Trigger can activate as long as you
are in AUTO Mode.
Trigger can only activate in AUTO, ON,
or TIMER Mode. Please leave ALARM
SETTING to arm the controller.