background image

Содержание AC-ATS3

Страница 1: ...USER MANUAL USER MANUAL AIRTITAN SERIES CRAWLSPACE AND BASEMENT VENTILATION FANS...

Страница 2: ......

Страница 3: ...oduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL su...

Страница 4: ...L AC ATS3 AC ATS7 AC ATT3 AC ATT7 AC ATT8 AC ATT8 N UPC A 819137023727 819137023734 819137020467 819137020474 819137020481 819137020498 MANUAL CODE AT2208X3 EC models CANNOT be daisy chained with DC m...

Страница 5: ...ntroller Mounting UISTM Platform UISTM Compatibility Compatibility Adding More Devices Programming Other Settings Download the App Add a Device FAQ Other AC Infinity Products Warranty Page 5 Page 6 Pa...

Страница 6: ...e chemical laden or wet atmospheres Ducted products must always be vented to outdoor areas Do not cover power cords with rugs or other fabric materials This product has rotating parts Safety precautio...

Страница 7: ...LLER Single button controller with circular readout display that enables fan speed control in ten speeds THERMAL PROBE The 12 foot corded sensor probe is constructed of stainless steel and ensures pre...

Страница 8: ...EM x1 SPEED CONTROLLER x1 SENSOR PROBE x1 WOOD SCREWS WALL HANG x2 WOOD SCREWS WALL HANG x1 UIS EXTENSION CORD M M x1 UIS EXTENSION CORD M M x1 SMART CONTROLLER x1 ALL MODELS SENSOR PROBE x1 FAN SYSTE...

Страница 9: ...arate the internal fan from the fan shell and front plate STEP 2 Identify the airflow direction to achieve your desired configuration airflow will blow on the label side Take out the fan and flip it o...

Страница 10: ...TEP 3 Reapply the screws to secure the shell and back plate to reassemble the fan AIRTITAN S3 S7 and T3 T7 A B NOTE For AIRTITAN T8 Series we offer both intake and exhaust configurations AIRTITAN S3 T...

Страница 11: ...s on ventilation opening where you wish to install the fan unit STEP 2 Position the fan unit over the ventilation opening Depending on the model the unit may be facing towards or away from the wall Pl...

Страница 12: ...a hole STEP 3 Foundation Block Mounting To install the unit onto a foundation brick or block mark the mounting hole locations using the four corners of the metal face plate Then drill 5 16 holes with...

Страница 13: ...SETUP AIRTITAN S3 S7 STEP 2 Plug the fan s power cord into an AC power outlet to power it and the controller STEP 1 Use the included UIS M M extension cord to connect the fan s EC Motor box to the S S...

Страница 14: ...EC Motor box to one of the controller s ports STEP 2 Plug the sensor probe into the controller s 3 5mm jack Route the probe head to spot areas as needed Keep the probe cord away from your HID grow li...

Страница 15: ...may use the included tie mounts and wire ties to manage the cords Secure the tie mounts onto a surface Loop the wire ties around the cords into the tie mounts STEP 3 Plug the fan s power cord into an...

Страница 16: ...et up temperature monitoring plug the male connector of the thermal probe into the designated probe port located at the bottom side of the fan unit STEP 2 Plug the fan s power cord into an AC power ou...

Страница 17: ...TITAN S3 S7 STEP 1 WALL MOUNTING Locate a spot free of obstruction and secure the anchor into your wall Twist the wood screw into the anchors STEP 2 WALL MOUNTING Hang the controller by the screw usin...

Страница 18: ...18 CONTROLLER MOUNTING AIRTITAN S3 S7 MAGNET MOUNTING Mount the controller on a steel surface using the magnet located behind the label...

Страница 19: ...TAN T3 T7 STEP 1 WALL MOUNTING Locate a spot free of obstruction and secure the anchors into your wall Twist the wood screws into the anchors STEP 2 WALL MOUNTING Hang the controller by the screws usi...

Страница 20: ...MAGNET MOUNTING You may also mount the controller onto a steel surface using the magnet located behind the label CORD ARRANGEMENT Cords may be routed into or outside of the kickstand grooves and thro...

Страница 21: ...21 CONTROLLER MOUNTING AIRTITAN T3 T7 KICKSTANDING Open the stand behind the controller to set it tilted on your desktop...

Страница 22: ...our devices based on your grow tent s temperature and humidity Create independent timers and schedules for customized activation in your desired timeframe Your grow system can be regulated using your...

Страница 23: ...to create more expansion ports up to 64 units supported with the use of 20 dongles Intended for exclusive use with AC Infinity controllers built with UIS ports UIS M F 4 PORT DONGLE UIS M F 2 PORT DO...

Страница 24: ...ty fan models that contain EC motors An AIRTITAN fan that uses an EC motor will use a power brick while on that does not use an EC motor will lack a power brick Note that certain models that previousl...

Страница 25: ...25 ADDING MORE DEVICES The CONTROLLER 69 is built with four ports that enable you to power and control multiple devices at the same time See images below for a sample configuration...

Страница 26: ...ing the speed button increases the fan speed in one unit increments Pressing the button at the 10 setting will set the fan speed back to 0 POWERING ON OFF Holding the speed button for 4 seconds will t...

Страница 27: ...ycles through the controller s settings DISPLAY CLOCK F C CALIB T H and TRANS T H 2 MODE BUTTON Cycles through the controller s modes OFF ON AUTO 4 triggers TIMER to ON TIMER to OFF CYCLE ON and OFF a...

Страница 28: ...ntering the ALL port will resume its programming INDIVIDUAL PORT Navigate to a numbered port with a connected device to set individual programming Programming will run in the background even while you...

Страница 29: ...IMER TO ON TIMER TO OFF CYCLE On and Off and SCHEDULE On and Off MINIMUM LEVEL Your devices will run at the level set in OFF Mode as the minimum level when triggered to turn OFF These other modes incl...

Страница 30: ...YCLE Mode TIMER TO ON Mode TIMER TO OFF Mode and SCHEDULE Mode Do not set the ON Mode figure to zero or your device will turn off when it s triggered ON in all modes ON MODE Your devices will actively...

Страница 31: ...is typically used with devices like air conditioners and cooling fans to help lower the temperature when it gets too hot For example if you set a high temperature trigger of 90 F then your device wil...

Страница 32: ...ger to create a specific range in which the devices are active This is typically used with devices like heaters and seedling mats to help raise the temperature when it gets too cold For example if you...

Страница 33: ...tive This is typically used with devices like dehumidifiers to help lower the humidity when it gets too humid For example if you set a high humidity trigger of 70 then your device will activate when t...

Страница 34: ...tive This is typically used with devices like humidifiers to help raise the humidity when it gets too dry For example if you set a low humidity trigger of 50 then your device will activate when the hu...

Страница 35: ...it until you return to this mode T SERIES PROGRAMMING TIMER TO OFF MODE Pressing the up or down button sets a countdown time During the countdown your device will be set to ON Once the timer ends your...

Страница 36: ...will run at the level set in ON Mode When the devices are deactivated they will run at the level set in OFF Mode The countdown will begin if no buttons are pressed for 5 seconds The time left on the...

Страница 37: ...the level set in ON Mode When the devices are triggered to deactivate they will run at the level set in OFF Mode The countdown will begin if no buttons are pressed for 5 seconds The time left on the c...

Страница 38: ...brightness level at 2 and 3 respectively and will dim down the brightness to level 1 when the controller is not being used after 15 seconds CONTROLLER SETTINGS Pressing the setting button will cycle...

Страница 39: ...u cycle through 12 00 each time the units will automatically change to AM or PM The clock time is located at the top right corner of the display F C SETTING Changes the displayed units to Fahrenheit o...

Страница 40: ...ements The calibration cycle ranges from 20 F to 20 F or 10 C to 10 C and will be applied to the sensor probe s measurements CALIBRATION HUMIDITY SETTING Adjusts the relative humidity reading the sens...

Страница 41: ...When the sensor temperature first reaches or exceeds the high temperature trigger point the level will increase by one exiting OFF Mode Each time the threshold level is crossed the level will ramp up...

Страница 42: ...usts how gradually your device will shift between levels when triggered ON by the AUTO Mode s humidity trigger This will determine how much the probe humidity needs to increase to step up to the next...

Страница 43: ...PROGRAMMING Displays when an advance program set in the app is active ADV will appear and override the controller if an automation program is in use AUTO MODE ALERT Flashes whenever any of the auto m...

Страница 44: ...erature humidity meet the trigger point set in the app DISPLAY LOCK ALERT Displays when you lock the controller The icon will flash and beep if you attempt to adjust the controller while it is still l...

Страница 45: ...ed nor will you be able to switch modes Holding the setting button again will unlock the controller HOLD HIDE SCREEN Lock the controller so no settings can be adjusted See above Then press the setting...

Страница 46: ...arching AC Infinity Open the AC Infinity app and follow the instructions on page 47 49 to pair your controller with the app Open the smart phone camera and scan the QR code below to download the AC In...

Страница 47: ...rting the pairing process SETUP AND PAIRING Power your device on before pairing your device with the app Refer to pages 14 16 for more information regarding controller setup 1 Tap on the tab to add yo...

Страница 48: ...48 ADD A DEVICE Hold the port button for 5 seconds to activate Bluetooth Wait for the Bluetooth icon to start flashing on your controller s screen Select CONTROLLER 69 to begin pairing 3 4...

Страница 49: ...o complete the pairing process Your controller will appear in your smart device with a unique ID Please note When pairing the app around multiple controllers move your mobile device closer to your des...

Страница 50: ...gure set in OFF Mode determines the device s level when it s triggered to be OFF in all other modes Set this figure to zero if you want the device to turn off when triggered OFF If this is occurring i...

Страница 51: ...point the device will increase by one level The lower the transition threshold is set to the easier it will be for the device to ramp up in levels If set to zero the device will jump to the max set s...

Страница 52: ...s powered on afterwards your settings will remain CONTROLLER 69 FAQ Q Why does the app ask me for location permissions A The app requires location permissions to find the relative position of your sma...

Страница 53: ...crawlspace fan A To flip the fan blades unscrew the bolts from the steel plate and the body Flip the fans within the body and screw the bolts back in Q How far can I mount the controller from the fan...

Страница 54: ...s IP55 rated for resistance against splashing water but it is not completely waterproof and should not be submerged in water Q Will this fan help with Radon mitigation A Yes The AIRTITAN will ventilat...

Страница 55: ...ontrols at acinfinity com Shutter Fans The AIRLIFT series is a line of shutter exhaust fans designed to expel heat moisture odor and dust from spaces like greenhouses garages attics and sheds It featu...

Страница 56: ...e date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a...

Страница 57: ...part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in...

Страница 58: ......

Страница 59: ......

Страница 60: ...www acinfinity com...

Отзывы: