28
CONTROLLER MODES
Pressing the mode button will cycle through the controller’s available programming modes: OFF, ON,
AUTO (4 triggers), TIMER TO ON, TIMER TO OFF, CYCLE (On and Off), and SCHEDULE (On and
Off).
OFF MODE
Your fan will not run while in this mode. The fan
speed set while in this mode establishes the
minimum speed in other modes. When the fan
is triggered to turn OFF in all other modes, it will
instead run at the speed set here.
ON MODE
Your fan will actively run at the speed set here,
regardless of the probe’s reading. The ON mode
also serves as the maximum speed setting the
other modes will run in.
AUTO MODE (HIGH TEMPERATURE TRIGGER)
Pressing the up or down button sets the high
temperature trigger. The fans will activate if the
probe’s reading meets or exceeds this threshold.
Once triggered, the fan will gradually ramp up
to the speed set in ON mode. If the probe’s
reading falls below this trigger point, the fans will
gradually slow down to a stop or at the speed set
in OFF mode.
You may set this trigger below the low
temperature trigger to create a specific range in
which the fan is active.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other than
zero, the fans will run at that speed when
triggered to turn off.