19
6. With both tugs placed 5 inches less than the width measured, assuming it is possible and
not at its minimum width, power one of the tugs on to aid in aligning the tubes. Align the
center tube and the end numbered tube insert so they are concentric with one another. Re-
move the T-Handle pin from step three and looking down on the adjustment handle rotate it
clockwise guiding the tube to the desired length. Once the desired length has been achieved
insert the T-Handle pin to connect both the center tube and end numbered tube together
Center Tube
End Numbered Tube
T-Handle Pin (Step 3)
5. Slide the smaller diameter end of the end numbered tube insert into the swivel connection
shown above. Align the non threaded thru holes and while holding the insert in place screw
in Shoulder Bolt (Part #95655).