abyzz A100 Скачать руководство пользователя страница 15

Operation

In  the  "Permanent"  operating  mode  (set  when  delivered),  you  can  use  the  start/
stop button to  start or  stop the  motor. You can  adjust the speed  using  the  up and 
down buttons. If you want to store the new speed  permanently, press "M". The set 
value is then  retained by the system. The  start/stop setting  is stored automatically 
so  that the pump automatically starts  in  its previous operating  mode  following  an 
interruption in the operating voltage or if the mains switch is switched off.

If  you  want  to  enter  the  menu  to  view  operating  data  or  to  program  the  pump, 
press "M".

The  menu  appears and the current operating  mode  is displayed. Use the  up and 
down buttons  to  navigate in  the  menu.  The software status,  operating hours, and 
operating mode are displayed one after the other.

The contrast of the display may be  adjusted in  the screen „Software & Kontrast“ by 
keeping the „Start/Stop“ button pressed and pressing the buttons „up“ or „down“.

If  you  want  to  change  the  operating  mode,  press  the  start/stop  button  on  the 
operating mode display. You can  now  use  the up  and  down  buttons to  change  the 
operating mode. There are the following operating modes:

a)  Permanent: The pump runs continuously at a set speed.

b)  Wave: The pump switches between two different set speeds at a set interval.

c)  Random: The  pump  changes speed within  a  range defined by a  minimum  and 

maximum value at a set time.

d)  Random  2:  The  pump  changes  speed  within  a  range  defined  by  a  minimum 

and maximum value at a random time.

Once you  have selected  the  operating mode, press the  start/stop  button. You are 
then  asked  to  enter  the  required  data  (minimum  and  maximum  power,  time 
interval).  Confirm  each  setting  by  pressing  the  start/stop  button.  When  you  are 
finished,  the  settings  are  saved  automatically  and  the  system  returns  to  the 
overview.

                                                             15

Содержание A100

Страница 1: ...Operating Manual A100 1 ...

Страница 2: ...to the products described in this manual shall be handled exclusively as per the guarantee conditions of the manufacturer The product specifications may deviate from the information in this manual due to technical improvements and innovations Abyzz BOOSTMODE and venotec are registered trademarks Valid as of 04 02 2014 2 ...

Страница 3: ... 8 Warnings 9 Proper use and general information 10 Installation of driver 11 Installation of pump 12 Commissioning 13 Run in phase 13 Description of control elements 14 Operation 15 Maintenance 18 Guarantee 23 Technical changes 24 Troubleshooting 24 Disposal 25 Technical data 25 Materials 26 Appendix 27ff Test report 29 3 ...

Страница 4: ... and following run in phase 14 Fig 3 Overview of messages 16 Fig 4 Abyzz boost mode 17 Fig 5 Pump with pump head 18 Fig 6a b Disassembly of pump head 19 Fig 7 Removing impeller group 20 Fig 8 O ring position and assembly 21 Fig 9 Assembly of pump head 22 Fig 10 Flow charts 27 Fig 11 Dimension of pump A100 28 4 ...

Страница 5: ... of this product for as long as possible please read this manual carefully and observe our recommendations Should the quality of the product not meet your expectations please contact the dealer who sold you the pump or contact us directly We recommend that you use the provided form to register your product with us so that we can provide you with the best possible service Please make sure that the ...

Страница 6: ...Scope of delivery 1 Abyzz A100 pump with 2m cable including pump stand 1 Abyzz A100 driver 1 Abyzz connecting cable for Abyzz peripheral devices 1 Abyzz mains cable 1 Registration form 1 Owners manual 6 ...

Страница 7: ...e a long lifetime and meet the highest requirements and quality standards Our products are developed and manufactured in Germany Thus they deserve this label Made in Germany The electronic control unit has optimum operating properties In particular these properties include the following Variable speed range 0 100 Programmable control unit including Abyzz BOOSTMODE Dry run protection Soft startup B...

Страница 8: ...displayed centrally on the ACS display There are two D sub connectors on the bottom of the Abyzz A200 pump driver for this purpose The connection labelled Master is always connected in the direction of the ACS and the connection labelled Slave is always connected in the direction of the next Abyzz pump Abyzz interface AInt The Abyzz interface allows you to integrate your Abyzz pumps into existing ...

Страница 9: ...sure that supply lines connectors and the driver are kept dry and protect the components from damage Do not work on cabling or the driver if you have wet hands Do not use the product if any of the people in the vicinity are in the water or if anyone is in contact with the water Check the product for damage before use Never use a product that you know is damaged Connect Abyzz products only to to a ...

Страница 10: ... the wear rate Resulting damage is not covered by the guarantee The pump is not a self priming pump and must therefore always be installed below the water level Please observe all generally valid national and international requirements when installing the pump The maximum working pressure may not exceed 0 8 bar Prior to being placed into storage the product must be thoroughly cleaned with freshwat...

Страница 11: ...ot switch on multiple drivers on the same fuse at the same time Do not use multi socket strips and do not exceed the permitted connected load of your supply line under any circumstances Ambient temperature and cooling The product can be used at ambient temperatures of between 2 C and 40 C To ensure sufficient cooling the driver should be at least 30 cm away from any other objects walls ceilings ca...

Страница 12: ...of driver Installation of pump The Abyzz pump can be immersed to a depth of 2 metres or installed in a dry position both either horizontally or with outlets down On the intake side make sure that the water can flow in freely and protect the intake by means of a screen suitable for keeping coarse particles sand filter cotton fibres etc away from the impeller wheel When laying the piping make sure t...

Страница 13: ...safeguard these properties Connect the Abyzz mains cable with the driver plug the mains cable into a suitable earth wall socket and switch on the mains switch see fig 1a The LED flashes You can start and stop the pump in any operating mode by pressing the start stop button If the pump is running dry at more than a third of its output the dry run protection function is activated This function switc...

Страница 14: ...button to switch the display back on The overview changes every 2 seconds as follows and displays the following operating data Adjusted power in Driver temperature Driver status and ACS adress if used Operating mode Actual energy saving BOOSTMODE adjustment The text displayed in the first line changes from Stopped to Running if you increase the speed and switch on the pump LED The LED flashes to s...

Страница 15: ...e display may be adjusted in the screen Software Kontrast by keeping the Start Stop button pressed and pressing the buttons up or down If you want to change the operating mode press the start stop button on the operating mode display You can now use the up and down buttons to change the operating mode There are the following operating modes a Permanent The pump runs continuously at a set speed b W...

Страница 16: ...Fig 3 Overview of messages 16 ...

Страница 17: ...s it possible to set up a short burst to get rid of debris This burst can be programmed independently to the operating mode chosen Fig 4 Abyzz BOOSTMODE In Fig 4 you see as an example the burst which is overriding the control of the Abyzz random program 17 ...

Страница 18: ...s becoming trapped Do not place any metallic parts near to the impeller Abyzz pumps are practically maintenance free if used properly If the flow rate drops there may be particles of dirt that need to be removed in the impeller wheel Also slight vibrations can be an indication that the impeller wheel is dirty To clean it separate the pump head from the motor bayonet coupling see Fig 6 and pull out...

Страница 19: ...Fig 6a b Disassembly of pump head 19 ...

Страница 20: ...ar bearing is in the correct position inside the motor If necessary push the bearing into position with a blunt object e g the handle of a screwdriver Make sure that the O ring for the vibration isolation and sealing is in the right position before reassembling the pump Carefully place the impeller into the motor block and press the assembly into the bearing seat until the bearing bracket is flush...

Страница 21: ...Fig 8 O ring position and assembly Place the O ring on the notch of the pump head and make sure it is properly placed before closing the bayonet flange again 21 ...

Страница 22: ...ead In systems that are constantly and intensively subjected to limescale e g hard coral ponds the pump must be regularly descaled Tip We recommend that you use a weak vinegar solution to clean the pump to avoid damaging it 22 ...

Страница 23: ... installation or interventions and changes carried out by unauthorized persons We expressly exclude such scenarios from our scope of liability Any secondary damages such as the loss of coral fish or water damage caused by pump failure or a lack of intake protection are expressly excluded from guarantee and warranty claims Calcination inside the pump and any resulting damage to the product or motor...

Страница 24: ...a Switch off the device and switch back on after 10 seconds Status Imax a Overcurrent fault motor overloaded a Check motor to make sure that it can move freely Status MOTOR a Motor not detected a Check connection to motor check plug Status TEMP a Driver overheated a Let the driver cool down lower the ambient temperature Status DRYRUN a Motor has run dry or is drawing in air a Check the water level...

Страница 25: ...ease us from our obligations as per Section 10 Paragraph 2 of the ElektroG Electrical and Electronic Equipment Act and absolve us from all upcoming claims from third parties Technical data Maximum flow rate 8 500 l h Rated flow rate 7 200 l h Discharge flow speed maximum 4 2 m s rated 3 8 m s Delivery height maximum 6 0 m rated 5 5 m Rated input 4 100 W Operating voltage 90 230V 50 60Hz For detail...

Страница 26: ...act with the medium being conveyed Housing Pump head Impeller wheel ABS GF 20 PA 6 Flushing line PVC PU Shaft WCNi Impeller Titanium grade 2 Screws Titanium grade 2 Bearings SSIC O ring Bearing seat Device feet NBR CR EPDM Motor cable PU Jointing compound PU 26 ...

Страница 27: ...Fig 10 Flow charts 27 ...

Страница 28: ...Dimensions and weight Fig 11 Dimensions pump A100 28 ...

Страница 29: ...X200 IPX400 complies with the following specifications EG Richtlinie EMV 2004 108 EG Applied harmonized standards DIN EN 61000 6 1 DIN EN 61000 6 2 DIN EN 61000 6 4 DIN EN 61000 3 2 This is a EMI class A product In some environments it can cause electromagnetic interference In this case it obligates to the user to perform adequate measures 29 ...

Страница 30: ...umber driver ____________________ Serial number motor ____________________ Flow rate on test bench __________ l h nominal Maximum head pressure __________ bar Max power consumption __________ W Rotation OK ______ Noise level OK ______ _________________________ signature inspector stamp 30 ...

Страница 31: ...Notes 31 ...

Страница 32: ...www abyzz de www venotec de 32 ...

Отзывы: