Maintenance
22 EN
Maintenance
In the case that an external power supply is being used please remember to
replace the batteries before their expiry date.
If the batteries need to be replaced, the alarm control panel will display the error
message "FKBDT == batt low". In this case, the batteries should be replaced by an
installer.
The keys of the control panel must undergo functional testing every year; the device
must also be cleaned.
Make sure that the system is not operating before carrying out the
functional testing
for the keys
.
In installer mode, select "Test
wireless control panel
wireless control panel 01-
08".
Select the wireless control panel required. The display now shows "Press key to test".
Press the keys on the control panel as follows in order to test them:
Press 4 or 6 (numerical) buttons on the keypad in sequence, followed by a function
button: The display now shows the keys that were pressed
– e.g. "1234A".
A =
B =
C =
D =
Press both fire, hold up, medical or social care buttons simultaneously to test the
manual trigger function of alarms. The display now shows the respective
abbreviations.
F =
P =
M =
H =
Clean
the outside of the housing with a soft, dry cloth. Do not use water or any form
of solvent or cleaning agent.
Содержание FUBE50001
Страница 25: ...DE 25...
Страница 50: ...EN 25...
Страница 75: ...NL 25...
Страница 100: ...FR 25...
Страница 101: ...FUBE50001 14 H 115013 Version 2 8 BOM 12828302 Secvest tr dl s betjeningsenhed DA Installations og betjeningsvejledning...
Страница 125: ...DA 25...
Страница 126: ...FUBE50001 14 H 115013 Versi n 2 8 BOM 12828302 Unidad de mando inal mbrica Secvest ES Manual de instalaci n y uso...
Страница 150: ...ES 25...