8.) BACK LIGHT
Without jumper (default) – The lighting of the display and the number
keys is switched off. If a key is pressed, the lighting switches on at full
strength for 5 seconds.
9.) Volume adjustment
Use this potentiometer to adjust the volume of the internal signalling
device and the connected loudspeakers.
Connecting loudspeakers (optional)
External 16 Ohm loudspeakers (in series with internal loudspeaker).
4.
Technical Data
Power consumption
90mA max. at
12V DC
Display
2 lines each with 16 characters
Zones
2 Zones, DEOL with anti-masking
Outputs
1 output negatively switching,100mA max.
Dimensions
134mm x 134mm x 23mm (HxWxD)
Weight
200g
Ambient operating
temperature
-10° to 55°C
Ambient operating
humidity
Max. 96%
© Security-Center GmbH & Co. KG, ABUS Group, April 2008